An electric-eel-inspired soft power source from stacked hydrogels

Progress towards the integration of technology into living organisms requires electrical power sources that are biocompatible, mechanically flexible, and able to harness the chemical energy available inside biological systems. Conventional batteries were not designed with these criteria in mind. The electric organ of the knifefish Electrophorus electricus (commonly known as the electric eel) is, however, an example of an electrical power source that operates within biological constraints while featuring power characteristics that include peak potential differences of 600 volts and currents of 1 ampere. Here we introduce an electric-eel-inspired power concept that uses gradients of ions between miniature polyacrylamide hydrogel compartments bounded by a repeating sequence of cation- and anion-selective hydrogel membranes. The system uses a scalable stacking or folding geometry that generates 110 volts at open circuit or 27 milliwatts per square metre per gel cell upon simultaneous, self-registered mechanical contact activation of thousands of gel compartments in series while circumventing power dissipation before contact. Unlike typical batteries, these systems are soft, flexible, transparent, and potentially biocompatible. These characteristics suggest that artificial electric organs could be used to power next-generation implant materials such as pacemakers, implantable sensors, or prosthetic devices in hybrids of living and non-living systems.

[1]  E. Schoffeniels ION MOVEMENTS STUDIED WITH SINGLE ISOLATED ELECTROPLAX * , 1959, Annals of the New York Academy of Sciences.

[2]  Hao Sun,et al.  Electrochemical Capacitors with High Output Voltages that Mimic Electric Eels , 2016, Advanced materials.

[3]  F. Sigworth,et al.  Patch recordings from the electrocytes of Electrophorus electricus. Na currents and PNa/PK variability , 1991, The Journal of general physiology.

[4]  Filip Ilievski,et al.  Soft robotics for chemists. , 2011, Angewandte Chemie.

[5]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[6]  Yu-Te Liao,et al.  A single-pixel wireless contact lens display , 2011, Journal of Micromechanics and Microengineering.

[7]  M. V. Brown,et al.  ELECTRICAL CHARACTERISTICS OF ELECTRIC TISSUE , 1946 .

[8]  L. Poole-Warren,et al.  Poly(vinyl alcohol)-heparin biosynthetic microspheres produced by microfluidics and ultraviolet photopolymerisation. , 2013, Biomicrofluidics.

[9]  Kenneth C Catania,et al.  Leaping eels electrify threats, supporting Humboldt’s account of a battle with horses , 2016, Proceedings of the National Academy of Sciences.

[10]  N. Aluru,et al.  Single-layer MoS2 nanopores as nanopower generators , 2016, Nature.

[11]  David A. LaVan,et al.  Designing artificial cells to harness the biological ion concentration gradient. , 2008, Nature nanotechnology.

[12]  Michael R. Sussman,et al.  Genomic basis for the convergent evolution of electric organs , 2014, Science.

[13]  M. V. Brown The electric discharge of the electric EEL , 1950, Electrical Engineering.

[14]  R. Keynes,et al.  Membrane potentials in the electroplates of the electric eel , 1953, The Journal of physiology.

[15]  Raeed H. Chowdhury,et al.  Epidermal Electronics , 2011, Science.

[16]  Paul A Dayton,et al.  High-speed, clinical-scale microfluidic generation of stable phase-change droplets for gas embolotherapy. , 2011, Lab on a chip.

[17]  H. Grundfest,et al.  Analysis of Spike Electrogenesis and Depolarizing K Inactivation in Electroplaques of Electrophorus electricus, L , 1965, The Journal of general physiology.

[18]  Sohyun Kim,et al.  Additive manufacturing of hydrogel-based materials for next-generation implantable medical devices , 2017, Science Robotics.

[19]  Robert N Weinreb,et al.  Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma. , 2012, Archives of ophthalmology.

[20]  Bingcheng Lin,et al.  Microvalve-actuated precise control of individual droplets in microfluidic devices. , 2009, Lab on a chip.

[21]  G. Whitesides Assumptions: taking chemistry in new directions. , 2004, Angewandte Chemie.

[22]  CARL C. ENGER,et al.  Biologically Energized Cardiac Pacemaker: in vivo Experience with Dogs , 1968, Nature.

[23]  Ying-Chih Lai,et al.  Electric Eel‐Skin‐Inspired Mechanically Durable and Super‐Stretchable Nanogenerator for Deformable Power Source and Fully Autonomous Conformable Electronic‐Skin Applications , 2016, Advanced materials.

[24]  A. Gotter,et al.  Electrophorus electricus as a model system for the study of membrane excitability. , 1998, Comparative biochemistry and physiology. Part A, Molecular & integrative physiology.

[25]  Koryo Miura,et al.  Method of Packaging and Deployment of Large Membranes in Space , 1985 .

[26]  C. W. Coates,et al.  Effect of potassium on electroplax of Electrophorus electricus. , 1957, Journal of cellular and comparative physiology.

[27]  R. E. Pattle Production of Electric Power by mixing Fresh and Salt Water in the Hydroelectric Pile , 1954, Nature.

[28]  Naveen Verma,et al.  Ultralow-power electronics for biomedical applications. , 2008, Annual review of biomedical engineering.

[29]  T. Yanagida,et al.  Development of an Experimental Apparatus for Simultaneous Observation of Optical and Electrical Signals from Single Ion Channels , 2002 .

[30]  R. T. Cox,et al.  ACTION POTENTIAL AND ENZYME ACTIVITY IN THE ELECTRIC ORGAN OF ELECTROPHORUS ELECTRICUS (LINNAEUS): I. CHOLINE ESTERASE AND RESPIRATION , 1942 .

[31]  Fred J Sigworth,et al.  Synthetic Protocells to Mimic and Test Cell Function , 2010, Advanced materials.

[32]  Anne M. Benneker,et al.  Desalination by Electrodialysis Using a Stack of Patterned Ion‐Selective Hydrogels on a Microfluidic Device , 2016 .