Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct.

Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, surgery, and joint factors on hinge alignment. The kinetic effects of the pins placement and elbow angle on concentric distraction and mobilization were also discussed. A unilaterally hinged elbow-fixator system with a 14 links and 10 degrees-of-freedom was instrumented into a humeroulnar model. The Denavit-Hartenberg method with the homogeneous transformation matrixes was applied to perform kinematic analysis of the linkage system. The predicted results revealed that the concurrence of hinge alignment (i.e., kinematic) and concentric distraction (i.e., kinetic) necessitates two telescopic tubes orthogonal to the elbow hinge. The degrees-of-freedom arrangement of the fixator articulators plays a significant role in hinge alignment. After joint distraction, two hinges might be misaligned due to the difference in the structural rigidity of the pins, fixator, and stiffened elbow. Furthermore, those two prerequisite are interactive and sensitive to elbow angle, fixator design, and pin placement of the bridged elbow-pin-fixator construct. In addition, the ideally concentric distraction might occur only at an elbow angle of 120 degrees owing to the ulnar anatomy. Meticulous planning is necessary for such highly technically demanding surgery.

[1]  J. Bijlsma,et al.  Can Ilizarov joint distraction delay the need for an arthrodesis of the ankle? A preliminary report. , 1995, The Journal of bone and joint surgery. British volume.

[2]  T D Brown,et al.  Hinged external fixation of the elbow: optimal axis alignment to minimize motion resistance. , 2000, Journal of orthopaedic trauma.

[3]  D. Ring,et al.  Treatment of Unreduced Elbow Dislocations with Hinged External Fixation , 2002, The Journal of bone and joint surgery. American volume.

[4]  M. Saleh,et al.  Articulated distraction of the hip. Conservative surgery for arthritis in young patients. , 1994, Clinical orthopaedics and related research.

[5]  Yoon Hyuk Kim,et al.  Kinematic simulation of fracture reduction and bone deformity correction under unilateral external fixation. , 2002, Journal of biomechanics.

[6]  B. Morrey,et al.  Treatment of the mobile, painful arthritic elbow by distraction interposition arthroplasty. , 2000, The Journal of bone and joint surgery. British volume.

[7]  I. Churchill-Davidson,et al.  Oxygenation in radiotherapy. II. Clinical application. , 1957, The British journal of radiology.

[8]  A Simkin,et al.  Do axial dynamic fixators really produce axial dynamization? , 1999, Injury.

[9]  D. Ruch,et al.  Hinged elbow fixation for recurrent instability following fracture dislocation. , 2001, Injury.

[10]  J. Bijlsma,et al.  Function of Stiff Joints May Be Restored by Ilizarov Joint Distraction , 1998, Clinical orthopaedics and related research.

[11]  B. Morrey Post-traumatic contracture of the elbow. Operative treatment, including distraction arthroplasty. , 1990, The Journal of bone and joint surgery. American volume.

[12]  A. Lundberg,et al.  Variation in the position and orientation of the elbow flexion axis. , 2003, The Journal of bone and joint surgery. British volume.

[13]  M. Saleh,et al.  Articulated Distraction of the Hip , 2000 .

[14]  M. V. Volkov,et al.  Restoration of function in the knee and elbow with a hinge-distractor apparatus. , 1975, The Journal of bone and joint surgery. American volume.

[15]  K. Mader,et al.  Die Operationstechnik der Distraktionsarthrolyse (Arthrodiatasis) bei Ellenbogensteife , 2004, Der Unfallchirurg.

[16]  B. Morrey Distraction arthroplasty. Clinical applications. , 1993, Clinical orthopaedics and related research.

[17]  M. Cohen,et al.  Post-traumatic contracture of the elbow. Operative release using a lateral collateral ligament sparing approach. , 1998, The Journal of bone and joint surgery. British volume.

[18]  T. Brown,et al.  Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.