Physical basis of ballistocardiography. III.

Two methods for calculating the amplitude characteristic of the high-frequency BCG, the difference in movement of subject and BCG taken into account, are compared and discussed. Some remarks are made upon the calculation of the amplitude characteristic of the middle-frequency BCG according to Nickerson.

[1]  J. L. Nickerson,et al.  A study of the physical properties of the ballistocardiograph. , 1954, American heart journal.

[2]  Yandell Henderson,et al.  THE MASS-MOVEMENTS OF THE CIRCULATION AS SHOWN BY A RECOIL CURVE , 1905 .

[3]  I. Starr,et al.  STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAM , 1939 .

[4]  M. Schwarzschild Ballistocardiography with Electronic Elimination of the Influence of Vibratory Properties of the Body , 1954, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[5]  H. C. Burger,et al.  Physical basis of the low-frequency ballistocardiograph. , 1953, American heart journal.

[6]  H. C. Burger,et al.  Physical basis of ballistocardiography. IV. The relative movement of subject and ballistocardiograph. , 1956, American heart journal.

[7]  S. A. Talbot,et al.  Dynamic Comparison of Current Ballistocardiographic Methods: Part I Artefacts in the Dynamically Simple Ballistocardiographic Methods , 1955, Circulation.

[8]  W. V. Wittern Ballistocardiography with elimination of the influence of the vibration properties of the body , 1953 .

[9]  M. B. Rappaport,et al.  Ballistocardiography: I. Physical Considerations , 1953, Circulation.

[10]  J W Gordon,et al.  Certain Molar Movements of the Human Body produced by the Circulation of the Blood. , 1877, Journal of anatomy and physiology.

[11]  S. A. Talbot,et al.  Dynamic Comparison of Current Ballistocardiographic Methods: Part II. Effect of a Platform in Ballistocardiographic Dynamics , 1955, Circulation.

[12]  J. E. Smith,et al.  Studies of the effect of a second degree of freedom in ballistocardiography. , 1953, American heart journal.

[13]  S. A. Talbot,et al.  Dynamic Comparison of Current Ballistocardiographic Methods: Part III. Derivation of Cardiovascular Force from Body Motions , 1955, Circulation.

[14]  Howard J. Curtis,et al.  THE DESIGN OF THE BALLISTOCARDIOGRAPH , 1944 .

[15]  L. Jonnart [Study of human ballistocardiograms. I. Technic]. , 1952, Acta cardiologica.

[16]  J. E. Smith,et al.  Simultaneous calibrated recording of displacement, velocity, and acceleration in ballistocardiography. , 1953, American heart journal.

[17]  W DOCK,et al.  Some technics for recording the ballistocardiogram directly from the body. , 1949, The American journal of medicine.

[18]  H. C. Burger,et al.  Physical basis of ballistocardiography. II. The quantities that can be measured with different types of ballistocardiographs and their mutual relations. , 1956, American heart journal.