Partial operating current characteristics to discriminate internal and external faults of differential protection zones during CT saturation

To protect transformers, transmission lines and busbar systems, low impedance current differential protection schemes based on percentage restraint characteristics are widely used in power systems. The main application issue of these schemes is mis-operation due to current transformer (CT) saturation during close-in external faults. A comprehensive fault discrimination algorithm is highly required for current differential protection schemes to overcome the CT saturation issue. The purpose of this study is to introduce a methodology based on partial operating current (POC) characteristics which discriminate internal and external faults of differential protection zones. The study includes the mathematical model of POC characteristics, a fault discriminating algorithm using POC features, and bus differential protection zone results. The results documented encompasses various possible short-circuit (fault) scenarios and indicate the capability of the proposed algorithm in discriminating internal and external faults under CT saturation conditions.

[1]  Ragab Abd Allah,et al.  Adaptive busbar differential relaying scheme during saturation period of current transformers based on alienation concept , 2016 .

[2]  S. A. Gafoor,et al.  A transient current based bus zone protection scheme using wavelet transform , 2008 .

[3]  Michael J. Thompson,et al.  Percentage restrained differential, percentage of what? , 2011, 2011 64th Annual Conference for Protective Relay Engineers.

[4]  C. Fernandez An Impedance-Based CT Saturation Detection Algorithm for Bus-Bar Differential Protection , 2001, IEEE Power Engineering Review.

[5]  Feng Gao,et al.  Modeling of constant distributed parameter transmission line for simulation of natural and envelope waveforms in power electric networks , 2005, Proceedings of the 37th Annual North American Power Symposium, 2005..

[6]  Y. Murakami,et al.  Microprocessor-based busbar protection relay , 1993 .

[7]  Armando Guzman,et al.  Performance Analysis of Traditional and Improved Transformer Differential Protective Relays , 2000 .

[8]  David Costello,et al.  Considerations for using high-impedance or low-impedance relays for bus differential protection , 2010, 2010 63rd Annual Conference for Protective Relay Engineers.

[9]  P.A. Crossley,et al.  A busbar differential protection relay suitable for use with measurement type current transformers , 2005, IEEE Transactions on Power Delivery.

[10]  M. Kaufmann,et al.  Busbar protection: a critical review of methods and practice , 1943 .

[11]  Ali Abur,et al.  Experimental evaluation of EMTP-based current transformer models for protective relay transient study , 1994 .

[12]  R. Midence,et al.  Phase angle comparison and differential rate of change methods used for differential protection of busbars and transformers , 2011, 2011 IEEE Electrical Power and Energy Conference.

[13]  J. B. Royle,et al.  Low impedance biased differential busbar protection for application to busbars of widely differing configuration , 1989 .

[14]  L. F. Kennedy,et al.  Harmonic-current-restrained relays for differential protection , 1938, Electrical Engineering.

[15]  Bogdan Z. Kasztenny,et al.  Tutorial on operating characteristics of microprocessor-based multiterminal line current differential relays , 2013 .

[16]  M. S. Sachdev,et al.  Microprocessor-based busbar protection system , 2000 .

[17]  Bogdan Z. Kasztenny,et al.  Digital low-impedance bus differential protection with reduced requirements for CTs , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).