Excimer-laser-assisted thrombolysis: the effect of laser fluence, repetition rate, and catheter size

The objective of this study was to evaluate the effect of laser fluence, repetition rate and catheter size on the ablation of thrombus by an excimer laser, in-vitro. Ablation of reconstituted thrombus was conducted with a XeCl (308 nm) excimer laser. Fluences of 30 and 45 mJ/mm2, repetition rates of 25 and 40 Hz, and catheters of sizes 0.9, 1.4, and 2.0 mm were used. Ablation efficiency (?g/J*pulse), and mass removal rate (?g/sec) were calculated by measuring the pre- and post-ablation weight of clot blocks (~2x1x1 cm3) placed on a precision scale. Depending on lasing parameters and catheter size, the ablation efficiency ranged from 0.51+/-0.09 to 1.13+/-0.20 ?g/J*pulse (N=12), while the mass removal rate ranged from 105+/-23 to 936+/-146 ?g/sec (N=12). Overall, there was a strong dependence of both quantities on the catheter size. Ablation efficiency was not significantly affected by either the fluence or the repetition rate, while mass removal rate increased with increased fluence and repetition rate. Excimer laser can effectively ablate thrombus in vitro. Catheter size affects both ablation efficiency and mass removal rate, while fluence and repetition rate mainly affect the mass removal rate.

[1]  J E Morris,et al.  Preclinical evaluation of a rheolytic catheter for percutaneous coronary artery/saphenous vein graft thrombectomy. , 1999, The Journal of invasive cardiology.

[2]  S. Prahl,et al.  Laser thrombolysis using long pulse frequency‐doubled Nd:YAG lasers , 1999, Lasers in surgery and medicine.

[3]  Frank Litvack,et al.  Recanalization of acute thrombus: Comparison of acute success and short-term patency after excimer laser coronary angioplasty, balloon angioplasty and intra-coronary thombolysis in pigs , 1991 .

[4]  A. Lansky,et al.  Effectiveness of excimer laser coronary angioplasty in acute myocardial infarction or in unstable angina pectoris. , 2001, The American journal of cardiology.

[5]  R. Sauerbrey,et al.  Thrombolysis by excimer laser photoablation , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[6]  Lisa A. Buckley,et al.  Characterization of an in-vitro laser thrombolysis model , 2001, SPIE BiOS.

[7]  O. Topaz,et al.  Application of excimer laser angioplasty in acute myocardial infarction , 2001, Lasers in surgery and medicine.

[8]  M. Fishbein,et al.  Use of laser energy to treat central pulmonary emboli: A preliminary report , 1993, Lasers in surgery and medicine.

[9]  O. Topaz,et al.  Excimer Laser Thrombolysis: An Emerging Option for Acute Ischaemic Coronary Syndrome , 2001, Lasers in Medical Science.

[10]  Lisa A. Buckley,et al.  Laser thrombolysis in an in-vitro model , 2000, Photonics West - Biomedical Optics.

[11]  G. Stone,et al.  Acute results, complications, and effect of lesion characteristics on outcome with the solid‐state, pulsed‐wave, mid‐infrared laser angioplasty system: Final multicenter registry report , 1998, Lasers in surgery and medicine.