Mass Flowmeter Using Heat Transfer for Dense Phase Solid Gas Two Phase Flow
暂无分享,去创建一个
gasifier, direct coal liquifer etc. as a new process. The authors developed a noninstrusive differential temperature sensing method for the mass flow rate 0-1, 000kg/h, mass flow ratio 0-47.2kg/kg using heat transfer cylinder 0.5m length of transport pipe 0.0175mƒÓ by elertric heater 202.5W. The relation between the mass flow, the heat transfer coefficient and the time constant of the meter are analyzed and measured. For 100ƒÊm aluminium oxide powder, over all heat transfer coefficient is maximum 286 W/m 2 K, the thermal efficiency from heater to the differential temperature is maximually 121% and the time constant of the meter is 1.5min for 1,000kg/h.
[1] R. Boothroyd,et al. Fully Developed Heat Transfer to a Gaseous Suspension of Particles Flowing Turbulently in Ducts of Different Size , 1970 .
[2] S. Matsumoto,et al. HEAT TRANSFER TO VERTICAL GAS-SOLID SUSPENSION FLOWS , 1978 .
[3] S. Matsumoto,et al. GAS TEMPERATURE DISTRIBUTION AND EDDY DIFFUSIVITY OF HEAT IN GASEOUS SUSPENSION FLOW , 1979 .