Condition Assessment of Paper Insulation in Oil-Immersed Power Transformers Based on the Iterative Inversion of Resistivity

The resistivity of oil impregnated paper will decrease during its aging process. This paper takes paper resistivity as an assessment index to evaluate the insulation condition of oil impregnated paper in power transformer. The feasibility of this method are discussed in two aspects: reliability and sensitivity. Iterative inversion of paper resistivity was combined with finite element simulation. Both the bisection method and Newton’s method were used as iterative methods. After the analysis and comparison, Newton’s method was selected as the first option of paper resistivity iteration for its faster convergence. In order to consider the spatial distribution characteristic of paper aging and enhance the calculation accuracy, the resistivity calculation is expanded to a multivariate iteration based on Newton’s method, in order to consider the spatial distribution characteristic of paper aging and improve the calculation accuracy. This paper presents an exploratory research on condition assessment of oil impregnated paper insulation, and provides some reference to the security and economy operation of power transformers.

[1]  J. Ruan,et al.  Charge transport in oil impregnated paper insulation under temperature gradient using transient upstream FEM , 2015 .

[2]  G. C. Stevens,et al.  Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers , 1994 .

[3]  Ruijin Liao,et al.  Effect of oil replacement on furfural analysis and aging assessment of power transformers , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Tapan K. Saha,et al.  Examining the ageing of transformer insulation using FRA and FDS techniques , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  A. Setayeshmehr,et al.  Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditions , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  Chao-Ming Huang,et al.  A Review of Dissolved Gas Analysis in Power Transformers , 2012 .

[7]  T. V. Oommen,et al.  A survey of aging characteristics of cellulose insulation in natural ester and mineral oil , 2011, IEEE Electrical Insulation Magazine.

[8]  Ruan Jiangjun,et al.  Charge Transport Simulation in Single-Layer Oil-Paper Insulation , 2016, IEEE Transactions on Magnetics.

[9]  C. Krause,et al.  Power transformer insulation – history, technology and design , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Naveen Kumar Sharma,et al.  Review of Artificial Intelligence Techniques Application to Dissolved Gas Analysis on Power Transformer , 2011 .

[11]  W. S. Zaengl,et al.  Dielectric Response Methods for Diagnostics of Power Transformers , 2003 .

[12]  Youyuan Wang,et al.  Quantitative evaluation of ageing condition of oil-paper insulation using frequency domain characteristic extracted from modified cole-cole model , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Ieee Standards Board IEEE guide for the interpretation of gases generated in oil-immersed transformers , 1992 .

[14]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil , 2000 .

[15]  I. Fofana,et al.  Potential of determining moisture content in mineral insulating oil by fourier transform infrared spectroscopy , 2016, IEEE Electrical Insulation Magazine.

[16]  S. M. Islam,et al.  Significance of cellulose power transformer condition assessment , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[17]  W. J. McNutt,et al.  Insulation thermal life considerations for transformer loading guides , 1992 .

[18]  Stefan Wolny,et al.  Aging degree evaluation for paper-oil insulation using the recovery voltage method , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  M.K. Pradhan,et al.  On the estimation of elapsed life of oil-immersed power transformers , 2005, IEEE Transactions on Power Delivery.

[20]  Ming-Ta Yang,et al.  Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[21]  Z. Wang,et al.  Aging assessment of kraft paper insulation through methanol in oil measurement , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  T. Saha,et al.  Review of time-domain polarization measurements for assessing insulation condition in aged transformers , 2003 .

[23]  K. D. Srivastava,et al.  Review of condition assessment of power transformers in service , 2002 .

[24]  P. Purkait,et al.  Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements , 2004, IEEE Transactions on Power Delivery.

[25]  M. Ali,et al.  Measuring and understanding the ageing of kraft insulating paper in power transformers , 1996 .

[26]  A. Abu-Siada,et al.  A Novel Fuzzy-Logic Approach for Furan Estimation in Transformer Oil , 2012, IEEE Transactions on Power Delivery.

[27]  I. Hohlein,et al.  Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil , 2005, IEEE Electrical Insulation Magazine.

[28]  Hui Ma,et al.  An Updated Model to Determine the Life Remaining of Transformer Insulation , 2015, IEEE Transactions on Power Delivery.

[29]  Ming Dong,et al.  Investigation on dielectric response characteristics of thermally aged insulating pressboard in vacuum and oil-impregnated ambient , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[30]  T. Prevost,et al.  Cellulose insulation in oil-filled power transformers: Part I - history and development , 2006, IEEE Electrical Insulation Magazine.

[31]  Tapan Kumar Saha,et al.  Review of modern diagnostic techniques for assessing insulation condition in aged transformers , 2003 .

[32]  Ruijin Liao,et al.  Quantitative analysis of ageing condition of oil-paper insulation by frequency domain spectroscopy , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[33]  D. Linhjell,et al.  Dielectric response of mineral oil impregnated cellulose and the impact of aging , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[34]  B. Chatterjee,et al.  An expert system approach for transformer insulation diagnosis combining conventional diagnostic tests and PDC, RVM data , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[35]  Abderrahmane Beroual,et al.  Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers , 2016 .

[36]  A. W. Stannett,et al.  A review of paper aging in power transformers , 1985 .