Computational Assessment of the Hazardous Release Dispersion from a Diesel Pool Fire in a Complex Building's Area

A hazardous release accident taking place within the complex morphology of an urban setting could cause grave damage both to the population’s safety and to the environment. An unpredicted accident constitutes a complicated physical phenomenon with unanticipated outcomes. This is because, in the event of an unforeseen accident, the dispersion of the hazardous materials exhausted in the environment is determined by unstable parameters such as the wind flow and the complex turbulent diffusion around urban blocks of buildings. Our case study focused on a diesel pool fire accident that occured between an array of nine cubical buildings. The accident was studied with a Large eddy Simulation model based on the Fire Dynamics Simulation method. This model was successfully compared against the nine cubes of the Silsoe experiment. The model’s results were used for the determination of the immediately dangerous to life or health smoke zones of the accident. It was found that the urban geometry defined the hazardous gasses dispersion, thus increasing the toxic mass concentration around the buildings.

[1]  Richard J. Perkins,et al.  Plume dispersion through large groups of obstacles – a field investigation , 1995 .

[2]  W. Rider,et al.  High-Resolution Methods for Incompressible and Low-Speed Flows , 2004 .

[3]  N. C. Markatos,et al.  Mathematical modeling of toxic pollutants dispersion from large tank fires and assessment of acute effects for fire fighters , 2009 .

[4]  Manabu Kanda,et al.  Turbulent flow similarity over an array of cubes in near-neutrally stratified atmospheric flow , 2008, Journal of Fluid Mechanics.

[5]  G. Cui,et al.  Flow pattern and pollutant dispersion over three dimensional building arrays , 2015 .

[6]  Dimitrios Pavlidis,et al.  How tall buildings affect turbulent air flows and dispersion of pollution within a neighbourhood. , 2018, Environmental pollution.

[7]  Eulàlia Planas,et al.  Experimental study of burning rate in hydrocarbon pool fires , 2001 .

[8]  Erich J. Plate,et al.  Wind-tunnel study of concentration fields in street canyons , 1999 .

[9]  P. Brimblecombe,et al.  Dispersion of traffic derived air pollutants into urban parks. , 2017, The Science of the total environment.

[10]  Vytenis Babrauskas,et al.  Estimating large pool fire burning rates , 1983 .

[11]  Bert Blocken,et al.  CFD simulation of outdoor ventilation of generic urban configurations with different urban densities and equal and unequal street widths , 2015 .

[12]  Simon Branford,et al.  Flow structure and near-field dispersion in arrays of building-like obstacles , 2014 .

[13]  Shouxiang Lu,et al.  Pool Fire Mass Burning Rate and Flame Tilt Angle under Crosswind in Open Space , 2016 .

[14]  N. C. Markatos,et al.  Mathematical modelling of buoyancy-induced smoke flow in enclosures , 1982 .

[15]  S. M. Tauseef,et al.  Multiple pool fires: Occurrence, simulation, modeling and management , 2014 .

[16]  D. Drikakis Advances in turbulent flow computations using high-resolution methods , 2003 .

[17]  Marc J. Assael,et al.  Fires, Explosions, and Toxic Gas Dispersions: Effects Calculation and Risk Analysis , 2010 .

[18]  Tom Heath,et al.  Tall Buildings and the Urban Skyline , 2000 .

[19]  Julia E. Flaherty,et al.  Urban Dispersion Program MSG05 Field Study: Summary of Tracer and Meteorological Measurements , 2006 .

[20]  F. Tang,et al.  Large eddy simulation of pollutant gas dispersion with buoyancy ejected from building into an urban street canyon. , 2011, Journal of hazardous materials.

[21]  Andrea Freda,et al.  Wind tunnel measurements of the urban boundary layer development over a historical district in Italy , 2017 .

[22]  Jong-Jin Baik,et al.  Effects of inflow turbulence intensity on flow and pollutant dispersion in an urban street canyon , 2003 .

[23]  P. Richards,et al.  Appropriate boundary conditions for computational wind engineering models using the k-ε turbulence model , 1993 .

[24]  Pietro Salizzoni,et al.  Flow and dispersion in street intersections , 2009 .

[25]  R. Huo,et al.  Large eddy simulation of fire-induced buoyancy driven plume dispersion in an urban street canyon under perpendicular wind flow. , 2009, Journal of hazardous materials.

[26]  W. Dabberdt,et al.  Concentration fields at urban intersections : fluid modeling studies , 1994 .

[27]  William D. Walton,et al.  Smoke Measurements Using an Advanced Helicopter Transported Sampling Package With Radio Telemetry (NIST SP 995) | NIST , 2003 .

[28]  N. Živković,et al.  Simulation of wind-driven dispersion of fire pollutants in a street canyon using FDS , 2013, Environmental Science and Pollution Research.

[29]  Alison S. Tomlin,et al.  Flow field measurements in the proximity of an urban intersection in London, UK , 2005 .

[30]  Peter Richards,et al.  Spectral models for the neutral atmospheric surface layer , 2000 .

[31]  N. C. Markatos,et al.  Simulation of airflow in one-and two-room enclosures containing a fire source , 2009 .

[32]  D. Grigoriadis,et al.  MHD flow past a circular cylinder using the immersed boundary method , 2010 .

[33]  Jong-Jin Baik,et al.  Modeling reactive pollutant dispersion in an urban street canyon , 2007 .

[34]  G. T. Johnson,et al.  An investigation of three-dimensional characteristics of flow regimes within the urban canyon , 1992 .

[35]  Darko N. Zigar,et al.  Large Eddy Simulation of wind flow impact on fire-induced indoor and outdoor air pollution in an idealized street canyon , 2016 .

[36]  Qiang Wang,et al.  Large eddy simulation of fire smoke re-circulation in urban street canyons of different aspect ratios , 2013 .

[37]  C. Halios,et al.  Effects of variability of local winds on cross ventilation for a simplified building within a full-scale asymmetric array: overview of the Silsoe field campaign , 2018 .

[38]  Rex Britter,et al.  Dispersion experiments in central London: the 2007 DAPPLE project. , 2009 .

[39]  Jong-Jin Baik,et al.  A Numerical Study of Flow and Pollutant Dispersion Characteristics in Urban Street Canyons , 1999 .

[40]  G. Van Tendeloo,et al.  Quantifying inflow uncertainties in RANS simulations of urban pollutant dispersion , 2017 .

[41]  Zoe Nivolianitou,et al.  A hazards assessment methodology for large liquid hydrocarbon fuel tanks , 2012 .

[42]  M. J. Davidson,et al.  Wind tunnel simulations of plume dispersion through groups of obstacles , 1996 .

[43]  R. P. Hoxey,et al.  Investigating the influence of neighbouring structures on natural ventilation potential of a full-scale cubical building using time-dependent CFD , 2017 .

[44]  Walter F. Dabberdt,et al.  Dispersion modeling at urban intersections , 1995 .

[45]  Z. Ning,et al.  A global relation of fire smoke re-circulation behaviour in urban street canyons , 2015 .

[47]  W. B. Johnson,et al.  An urban diffusion simulation model for carbon monoxide. , 1973, Journal of the Air Pollution Control Association.

[48]  F. T. Depaul,et al.  Measurements of wind velocities in a street canyon , 1986 .

[49]  Glenn P. Forney,et al.  Fire dynamics simulator- technical reference guide , 2000 .

[50]  Zoe Nivolianitou,et al.  Modelling pollutants dispersion and plume rise from large hydrocarbon tank fires in neutrally stratified atmosphere , 2010 .

[51]  Chun-Ho Liu,et al.  On the pollutant removal, dispersion, and entrainment over two-dimensional idealized street canyons , 2014 .

[52]  F. L. Ludwig,et al.  Validation and applications of an urban diffusion model for vehicular pollutants , 1973 .