Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations

Although polygonal-surface computational human phantoms can address several critical limitations of conventional voxel phantoms, their Monte Carlo simulation speeds are much slower than those of voxel phantoms. In this study, we sought to overcome this problem by developing a new type of computational human phantom, a tetrahedral mesh phantom, by converting a polygonal surface phantom to a tetrahedral mesh geometry. The constructed phantom was implemented in the Geant4 Monte Carlo code to calculate organ doses as well as to measure computation speed, the values were then compared with those for the original polygonal surface phantom. It was found that using the tetrahedral mesh phantom significantly improved the computation speed by factors of between 150 and 832 considering all of the particles and simulated energies other than the low-energy neutrons (0.01 and 1 MeV), for which the improvement was less significant (17.2 and 8.8 times, respectively).

[1]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[2]  W E Bolch,et al.  Voxel size effects in three-dimensional nuclear magnetic resonance microscopy performed for trabecular bone dosimetry. , 2000, Medical physics.

[3]  Hang Si,et al.  TetGen: A quality tetrahedral mesh generator and a 3D Delaunay triangulator (Version 1.5 --- User's Manual) , 2013 .

[4]  Harald Paganetti,et al.  Relative biological effectiveness (RBE) values for proton beam therapy. , 2002, International journal of radiation oncology, biology, physics.

[5]  Daniel Lodwick,et al.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry. , 2008, Medical physics.

[6]  V F Cassola,et al.  FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy , 2010, Physics in medicine and biology.

[7]  Daniel Lodwick,et al.  HYBRID COMPUTATIONAL PHANTOMS REPRESENTING THE REFERENCE ADULT MALE AND ADULT FEMALE: CONSTRUCTION AND APPLICATIONS FOR RETROSPECTIVE DOSIMETRY , 2012, Health physics.

[8]  X. Xu,et al.  Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms , 2010, Physics in medicine and biology.

[9]  Daniel Lodwick,et al.  The UF family of reference hybrid phantoms for computational radiation dosimetry , 2010, Physics in medicine and biology.

[10]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[11]  Min Cheol Han,et al.  DagSolid: a new Geant4 solid class for fast simulation in polygon-mesh geometry. , 2013, Physics in medicine and biology.

[12]  Deanna Hasenauer,et al.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models , 2007, Physics in medicine and biology.

[13]  S. Gibbs,et al.  A Monte Carlo method for patient dosimetry from dental X-ray. , 1982, Dento maxillo facial radiology.

[14]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[16]  Michael Fenech,et al.  Mitigating the risk of radiation-induced cancers: limitations and paradigms in drug development , 2014, Journal of radiological protection : official journal of the Society for Radiological Protection.

[17]  V. Cassola,et al.  Standing adult human phantoms based on 10th, 50th and 90th mass and height percentiles of male and female Caucasian populations , 2011, Physics in medicine and biology.

[18]  Wesley E Bolch,et al.  The influence of patient size on dose conversion coefficients: a hybrid phantom study for adult cardiac catheterization. , 2009, Physics in medicine and biology.

[20]  Haiou Shen,et al.  A tetrahedron-based inhomogeneous Monte Carlo optical simulator , 2010, Physics in medicine and biology.

[21]  X. Xu,et al.  Modelling and Monte Carlo organ dose calculations for workers walking on ground contaminated with Cs-137 and Co-60 gamma sources. , 2010, Radiation protection dosimetry.

[22]  Chan Hyeong Kim,et al.  HDRK-Man: a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver , 2008, Physics in medicine and biology.

[23]  D. Manocha,et al.  Development and application of the new dynamic Nurbs-based Cardiac-Torso (NCAT) phantom. , 2001 .

[24]  Christopher M Poole,et al.  Fast Tessellated Solid Navigation in GEANT4 , 2012, IEEE Transactions on Nuclear Science.

[25]  Min Cheol Han,et al.  HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver , 2008, Physics in medicine and biology.

[26]  Thomas Barker,et al.  CAD import for MONK and MCBEND by converting to Tetrahedral Mesh format , 2008 .

[27]  X. Xu,et al.  RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beams , 2009, Physics in medicine and biology.

[28]  Chan Hyeong Kim,et al.  A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation , 2011, Physics in medicine and biology.

[29]  Lin Su,et al.  Calculated organ equivalent doses for individuals in a sitting posture above a contaminated ground and a PET imaging room. , 2012, Radiation protection dosimetry.

[30]  J. W. Vieira,et al.  FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations , 2010, Physics in medicine and biology.

[31]  Qianqian Fang,et al.  Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates , 2010, Biomedical optics express.

[32]  Aiping Ding,et al.  Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose , 2012, Physics in medicine and biology.

[33]  Matthew R Maynard,et al.  The UF family of hybrid phantoms of the developing human fetus for computational radiation dosimetry , 2011, Physics in medicine and biology.