Detection of secondary arc extinction for adaptive single phase auto-reclosing based on local voltage behaviour

This study presents a non-communication based algorithm for detection of secondary arc extinction for adaptive single phase auto-reclosing of transmission lines. The algorithm is based on the behaviour pattern of the faulted phase voltage magnitude (VM) measured at the near end of the line. A prediction function is used to calculate the present VM few milliseconds in advance of its actual measurement. The difference between the actual and calculated values of the faulted phase VM is used as a criterion for detection of secondary arc extinction. A new method is proposed to analyse the arc extinction criterion which does not need a predefined threshold level. The algorithm uses low sampling frequency and is simple and fast. The algorithm can be applied on all transmission line configurations (transposed or untransposed) with different levels of reactive power compensation. The algorithm has been validated using the electromagnetic transient program software tool for simulation studies under many operational and fault cases. The presented test results for 465 cases verify the algorithm performance, which is not affected by the pre-fault line loading, the circuit breaker opening angle, arc type and fault location.

[1]  Tarlochan S. Sidhu,et al.  A High-Speed Adaptive Single-Phase Reclosing Technique Based on Local Voltage Phasors , 2017, IEEE Transactions on Power Delivery.

[2]  Sadegh Jamali,et al.  New approach to adaptive single pole auto-reclosing of power transmission lines , 2010 .

[3]  Navid Ghaffarzadeh,et al.  Adaptive single pole auto‐reclosing using discrete wavelet transform , 2011 .

[4]  Zhiqian Bo,et al.  A novel adaptive single-phase reclosure scheme using dual-window transient energy ratio and mathematical morphology , 2006, IEEE Transactions on Power Delivery.

[5]  M. Kizilcay,et al.  Digital simulation of fault arcs in power systems , 2007 .

[6]  M. R. Zadeh,et al.  Communication-Aided High-Speed Adaptive Single-Phase Reclosing , 2013, IEEE Transactions on Power Delivery.

[7]  V. Koschik,et al.  Staged Fault Tests with Single Phase Reclosing on the Winnipeg-Twin Cities 500kV Interconnection , 1982, IEEE Transactions on Power Apparatus and Systems.

[8]  R. K. HAUN 13 Years' Experience with Single-Phase Reclosing at 345 KV , 1978, IEEE Transactions on Power Apparatus and Systems.

[9]  Z.M. Radojevic,et al.  New Digital Algorithm for Adaptive Reclosing Based on the Calculation of the Faulted Phase Voltage Total Harmonic Distortion Factor , 2007, IEEE Transactions on Power Delivery.

[10]  Harold A. Peterson,et al.  A Method for Reducing Dead Time for Single-Phase Reclosing in EHV Transmission , 1969 .

[11]  Bin Wang,et al.  A Dual-Window Transient Energy Ratio-Based Adaptive Single-Phase Reclosure Criterion for EHV Transmission Line , 2007, IEEE Transactions on Power Delivery.

[12]  R.A. Rivas,et al.  A probabilistic approach for secondary arc risk assessment , 2004, IEEE Transactions on Power Delivery.

[13]  M. E. Hamedani Golshan,et al.  Detecting secondary arc extinction time by analyzing low frequency components of faulted phase voltage or sound phase current waveforms , 2006 .

[14]  Dong Xinzhou,et al.  Adaptive reclosure using high frequency fault transients , 2001 .

[15]  R. K. Aggarwal,et al.  New concept in transmission line reclosure using high-frequency fault transients , 1997 .

[16]  Masoud Khodadadi,et al.  A Noncommunication Adaptive Single-Pole Autoreclosure Scheme Based on the ACUSUM Algorithm , 2013, IEEE Transactions on Power Delivery.

[17]  Zuyi Li,et al.  Design of a novel phasor measurement unit-based transmission line auto reclosing scheme , 2011 .

[18]  K. H. Milne Single-Pole Reclosing Tests on Long 275-Kv Transmission Lines , 1963 .

[19]  Christian Romeis,et al.  Real-Time Adaption of Dead Time for Single-Phase Autoreclosing , 2016, IEEE Transactions on Power Delivery.

[20]  Zhe Chen,et al.  Adaptive optimal reclosure based on analysis of fault current transients , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).