How should airways resistance be measured in young children: mask or mouthpiece?

The reproducibility and acceptability of airways resistance measurements using the interrupter technique (MicroRint) obtained using a mouthpiece were compared with those using a face mask. Fifty children aged 4-7 yrs performed four sets of six Rint measurements; two using a mouthpiece and two using a face mask with integral mouthpiece. Complete data were obtained from 45 (90%) children using the mouthpiece and 43 (86%) children using the mask. The two methods were equally repeatable with comparable intraclass correlation coefficients (ICC) and coefficients of variation. Mean Rint values obtained using the mouthpiece were significantly lower than those using the face mask ((mean+/-SD) mouthpiece=0.81+/-0.18 kPa x L(-1) x s, mask=0.88+/-0.24 kPa x L(-1) x s p=0.0002). Although the mean paired differences between the two methods were small (0.07 kPa x L(-1) x s), the ICC and limits of agreement confirmed that the two methods could not be used interchangeably. Sixty-seven per cent of children preferred the face mask but this was more time-consuming (p = 0.03). Children did not produce more repeatable results using their preferred method, nor did they improve with practice. Repeatable airway resistance measurements using the interrupter technique can be obtained from young children using either a mouthpiece or a face mask, but there are significant clinical and statistical differences between the results obtained.

[1]  M. Silverman,et al.  The measurement of methacholine responsiveness in 5 year old children: three methods compared. , 1995, The European respiratory journal.

[2]  S. Ranganathan,et al.  Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting. , 1999, The European respiratory journal.

[3]  M. Silverman,et al.  Evaluation of the interrupter technique for measuring change in airway resistance in 5‐year‐old asthmatic children , 1995, Pediatric pulmonology.

[4]  H. Bisgaard,et al.  Observer variability of lung function measurements in 2-6-yr-old children. , 2000, The European respiratory journal.

[5]  J M Kinney,et al.  Effects of respiratory apparatus on breathing pattern. , 1980, Journal of applied physiology: respiratory, environmental and exercise physiology.

[6]  D J Hitchings,et al.  The accuracy of portable peak flow meters. , 1992, Thorax.

[7]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[8]  P. Shrout Measurement reliability and agreement in psychiatry , 1998, Statistical methods in medical research.

[9]  H. Bisgaard,et al.  Lung function measurement in awake young children. , 1995, The European respiratory journal.

[10]  Hans Bisgaard,et al.  Specific airway resistance, interrupter resistance, and respiratory impedance in healthy children aged 2–7 years , 1998, Pediatric pulmonology.

[11]  M. Silverman,et al.  Accuracy and sensitivity of the interrupter technique for measuring the response to bronchial challenge in normal subjects. , 1993, The European respiratory journal.

[12]  H. Bisgaard,et al.  Measurement of the specific airway resistance by plethysmography in young children accompanied by an adult. , 1997, The European respiratory journal.

[13]  E. Carter,et al.  Evaluation of the interrupter technique for the use of assessing airway obstruction in children , 1994, Pediatric pulmonology.

[14]  M. Silverman,et al.  A portable device based on the interrupter technique to measure bronchodilator response in schoolchildren. , 1996, The European respiratory journal.

[15]  M. Silverman,et al.  A flow interruption device for measurement of airway resistance. , 1991, The European respiratory journal.

[16]  J. Stocks,et al.  Nasal resistance during infancy. , 1978, Respiration physiology.

[17]  M. Silverman Childhood asthma and other wheezing disorders , 1995 .

[18]  M. Silverman,et al.  Comparison of four methods of assessing airflow resistance before and after induced airway narrowing in normal subjects. , 1995, Journal of applied physiology.

[19]  A Charloux,et al.  Interrupter technique versus plethysmography for measurement of respiratory resistance in children with asthma or cystic fibrosis , 2000, Pediatric pulmonology.

[20]  A. Milner,et al.  Peak Expiratory Flow Rates in Children Under 5 Years of Age , 1970, Archives of disease in childhood.

[21]  R Kraemer,et al.  Oscillatory pressure transients after flow interruption during bronchial challenge test in children. , 1997, The European respiratory journal.

[22]  P. Sly,et al.  Accuracy of mini peak flow meters in indicating changes in lung function in children with asthma , 1994, BMJ.

[23]  E. Vanninen,et al.  Interrupter technique for evaluation of exercise‐induced bronchospasm in children , 1999, Pediatric pulmonology.

[24]  G M Raab,et al.  Design and Analysis of Reliability Studies—the Statistical Evaluation of Measurement Errors , 1991 .

[25]  R. Buchdahl Childhood Asthma and Other Wheezing Disorders , 1996 .

[26]  H. Bisgaard,et al.  Measurement of lung function in awake 2–4‐year‐old asthmatic children during methacholine challenge and acute asthma: A comparison of the impulse oscillation technique, the interrupter technique, and transcutaneous measurement of oxygen versus whole‐body plethysmography , 1996, Pediatric pulmonology.

[27]  M. Silverman,et al.  Evaluation of a new interrupter device for measuring bronchial responsiveness and the response to bronchodilator in 3 year old children. , 1996, The European respiratory journal.

[28]  Graham Dunn,et al.  Review papers : Design and analysis of reliability studies , 1992 .

[29]  R. Dripps Lung function. , 1949, The American journal of roentgenology and radium therapy.