Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out

Platform - Structural analyses were performed for design seismic, live and dead load combinations for the freestanding platform over the partial DST mock-up section. The platform is to be used for Robotic ultrasonic inspection of the tank wall. It is a free standing structure anchored to floor slab with Hilti Kwik bolts.