In vivo MRI of submillisecond T2 species with two‐dimensional and three‐dimensional radial sequences and applications to the measurement of cortical bone water

Water in dense collagenous tissues such as tendons and ligaments, as well as water in cortical bone that occupies the spaces of the lacuno‐canicular system or is tightly bound to collagen, is not ordinarily detectable by MRI. Water proton T2 in these structures is generally less than 1 ms. Recent advances in instrumentation in conjunction with non‐Cartesian imaging strategies now allow center of k‐space to be scanned 100 µs or less after excitation. We examined the performance of two radial pulse sequences, a 2D sequence with half‐pulse excitation and a new 3D hybrid sequence with variable‐echo Cartesian encoding in the third dimension, on a whole‐body 3 T scanner. Both pulse sequences used long‐T2 soft‐tissue suppression pulses. The half‐pulse slice profiles observed experimentally agreed well with those computed on the basis of a numerical solution of Bloch equations. The techniques yielded a signal‐to‐noise ratio of the order of 25 in 9 min scan time at a nominal voxel size of 0.58 × 0.58 × 8 mm3 and 50–90 µs ‘echo time’ in the cortex of the tibial mid‐shaft. With the use of an external reference, the water volume fraction of cortical bone in four subjects (mean ± SD age 32.25 ± 5.3 years) was found to be 22.5 ± 2.7%, in good agreement with literature values. Copyright © 2007 John Wiley & Sons, Ltd.

[1]  D. Firmin,et al.  FID‐based lung MRI at 0.5 T: Theoretical considerations and practical implications , 1998, Magnetic resonance in medicine.

[2]  F W Wehrli,et al.  Variable TE gradient and spin echo sequences for in Vivo MR microscopy of short T2 species , 1998, Magnetic resonance in medicine.

[3]  P. Callaghan Principles of Nuclear Magnetic Resonance Microscopy , 1991 .

[4]  Bob S. Hu,et al.  Pulsed saturation transfer contrast , 1992, Magnetic resonance in medicine.

[5]  R. Robinson,et al.  The water content of bone. I. The mass of water, inorganic crystals, organic matrix, and CO2 space components in a unit volume of the dog bone. , 1957, The Journal of bone and joint surgery. American volume.

[6]  M A Fernández-Seara,et al.  Multipoint mapping for imaging of semi-solid materials. , 2003, Journal of magnetic resonance.

[7]  L DelaBarre,et al.  BISTRO: An outer‐volume suppression method that tolerates RF field inhomogeneity , 2001, Magnetic resonance in medicine.

[8]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[9]  J. B. Kneeland,et al.  Sodium MRI of human articular cartilage in vivo , 1998, Magnetic resonance in medicine.

[10]  J. Pauly,et al.  Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses , 2001, Magnetic resonance in medicine.

[11]  Dwight G Nishimura,et al.  Designing long‐T2 suppression pulses for ultrashort echo time imaging , 2006, Magnetic resonance in medicine.

[12]  J. Pauly,et al.  Boron‐11 imaging with a three‐dimensional reconstruction method , 1992, Journal of magnetic resonance imaging : JMRI.

[13]  J. D. O'Sullivan,et al.  A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography , 1985, IEEE Transactions on Medical Imaging.

[14]  Y M Ro,et al.  Multipoint K‐space point mapping (KPM) technique for NMR microscopy , 1994, Magnetic resonance in medicine.

[15]  Mark Bydder,et al.  Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging , 2003, Journal of computer assisted tomography.

[16]  J M Pauly,et al.  Design of practical T2‐selective RF excitation (TELEX) pulses , 1998, Magnetic resonance in medicine.

[17]  J L Ackerman,et al.  Multinuclear solid-state three-dimensional MRI of bone and synthetic calcium phosphates. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[18]  V. Bousson,et al.  CT of the middiaphyseal femur: cortical bone mineral density and relation to porosity. , 2000, Radiology.

[19]  Matthew D Robson,et al.  Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences. , 2005, Magnetic resonance imaging.

[20]  C F Beaulieu,et al.  MR imaging of articular cartilage of the knee: new methods using ultrashort TEs. , 1998, AJR. American journal of roentgenology.

[21]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[22]  Peter Börnert,et al.  Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling , 2006, Magnetic resonance in medicine.

[23]  A. Macovski,et al.  Variable-rate selective excitation , 1988 .

[24]  Yi Zhang,et al.  In vivo 17O NMR approaches for brain study at high field , 2005, NMR in biomedicine.

[25]  William H. Press,et al.  Numerical recipes in C. The art of scientific computing , 1987 .

[26]  Dana C Peters,et al.  Centering the projection reconstruction trajectory: Reducing gradient delay errors , 2003, Magnetic resonance in medicine.

[27]  D G Nishimura,et al.  Ultra‐short echo‐time 2D time‐of‐flight MR angiography using a half‐pulse excitation , 1999, Magnetic resonance in medicine.

[28]  S. Emid,et al.  High resolution NMR imaging in solids , 1985 .

[29]  Yan Wang,et al.  Density of organic matrix of native mineralized bone measured by water‐ and fat‐suppressed proton projection MRI , 2003, Magnetic resonance in medicine.

[30]  R. D. Ray,et al.  Bone Density and Composition , 1966 .

[31]  J. Reeve,et al.  A novel mechanism for induction of increased cortical porosity in cases of intracapsular hip fracture. , 2000, Bone.

[32]  Albert Macovski,et al.  MR Spectroscopic imaging of collagen: Tendons and knee menisci , 1995, Magnetic resonance in medicine.

[33]  F. Wehrli,et al.  Water Content Measured by Proton‐Deuteron Exchange NMR Predicts Bone Mineral Density and Mechanical Properties , 2003, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.