Use of spirometry to predict risk of pneumothorax in CT-guided needle biopsy of the lung.

OBJECTIVE Our goal was to assess the usefulness of spirometry to estimate the risk of pneumothorax in patients undergoing percutaneous needle biopsy with CT guidance for solitary pulmonary nodule (SPN). MATERIALS AND METHODS We studied the results of 51 consecutive percutaneous needle biopsies with CT guidance for SPN obtained between 1988 and 1990. Forty-five men and six women, aged 65 +/- 11 (36-86) years, were included in the study. All biopsies were performed under CT guidance, with 90 mm 25G needles (0.5 mm thickness) fitted into luer-type syringes. The number of needle pass attempts never exceeded three. A spirometry before biopsy was performed in all patients. RESULTS Pneumothorax occurred in only 10 cases (19%). The patients with pneumothorax showed lower lesion size, forced vital capacity (FVC), forced expiratory volume (FEV1), and FEV1/FVC ratio. The contribution of these factors to pneumothorax was analyzed by a logistic regression model. The FEV1 was most strongly associated with the incidence of pneumothorax. We developed an equation for predicting the risk of this complication. CONCLUSION We conclude that decreasing FEV1 is associated with a higher pneumothorax rate.

[1]  J. M. Viguer,et al.  Value OF CT-Guided Fine Needle Aspiration in Solitary Pulmonary Nodules with Negative Fiberoptic Bronchoscopy , 1994, Acta radiologica.

[2]  T. Lie,et al.  Risk of pneumothorax not increased by obstructive lung disease in percutaneous needle biopsy. , 1994, Chest.

[3]  S. Swensen,et al.  An integrated approach to evaluation of the solitary pulmonary nodule. , 1990, Mayo Clinic proceedings.

[4]  C. Virapongse,et al.  Low-risk large-needle biopsy of chest lesions. , 1989, Chest.

[5]  P. Selecky,et al.  Guidelines For Percutaneous Transthoracic Needle Biopsy , 1989 .

[6]  M. Levine,et al.  Transthoracic needle aspiration biopsy following negative fiberoptic bronchoscopy in solitary pulmonary nodules. , 1988, Chest.

[7]  K. Miller,et al.  Prediction of pneumothorax rate in percutaneous needle aspiration of the lung. , 1988, Chest.

[8]  K. Miller,et al.  Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests. , 1988, AJR. American journal of roentgenology.

[9]  F. Harrell,et al.  Regression modelling strategies for improved prognostic prediction. , 1984, Statistics in medicine.

[10]  R. Poe,et al.  Predicting risk of pneumothorax in needle biopsy of the lung. , 1984, Chest.

[11]  A. Deutsch,et al.  Flexible fiberoptic bronchoscopy and percutaneous needle lung aspiration for evaluating the solitary pulmonary nodule. , 1982, Chest.

[12]  J. Hanley,et al.  The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.

[13]  W. Sinner Complications of Percutaneous Transthoracic Needle Aspiration Biopsy , 1976, Acta radiologica: diagnosis.