Protein adsorption on materials for recording sites on implantable microelectrodes

Implantable microelectrodes have the potential to become part of neural prostheses to restore lost nerve function after nerve damage. The initial adsorption of proteins to materials for implantable microelectrodes is an important factor in determining the longevity and stability of the implant. Once an implant is in the body, protein adsorption takes place almost instantly before the cells reach the surface of an implant. The aim of this study was to identify an optimum material for electrode recording sites on implantable microelectrodes. Common materials for electrode sites are gold, platinum, iridium, and indium tin oxide. These, along with a reference material (titanium), were investigated. The thickness and the structure of adsorbed proteins on these materials were measured using a combination of atomic force microscopy and ellipsometry. The adsorbed protein layers on gold (after 7 and 28 days of exposure to serum) were the smoothest and the thinnest compared to all the other substrate materials, indicating that gold is the material of choice for electrode recording sites on implantable microelectrodes. However, the results also show that indium tin oxide might also be a good choice for these applications.

[1]  J. Andrade,et al.  Plasma Protein Adsorption: The Big Twelve a , 1987, Annals of the New York Academy of Sciences.

[2]  Wamadeva Balachandran,et al.  Silicon-based microelectrodes for neurophysiology fabricated using a gold metallization/nitride passivation system , 1996 .

[3]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[4]  K. Wise,et al.  Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity , 1988, IEEE Transactions on Biomedical Engineering.

[5]  G. Gross,et al.  Stimulation of monolayer networks in culture through thin-film indium-tin oxide recording electrodes , 1993, Journal of Neuroscience Methods.

[6]  H. K. Charles,et al.  Multisite microprobes for neural recordings , 1991, IEEE Transactions on Biomedical Engineering.

[7]  D.J. Anderson,et al.  Batch fabricated thin-film electrodes for stimulation of the central auditory system , 1989, IEEE Transactions on Biomedical Engineering.

[8]  W. Balachandran,et al.  Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers , 2000, Medical and Biological Engineering and Computing.

[9]  K. Wise,et al.  A three-dimensional microelectrode array for chronic neural recording , 1994, IEEE Transactions on Biomedical Engineering.

[10]  James M. Bower,et al.  Plasma-etched neural probes , 1996 .

[11]  J. Keddie Structural analysis of organic interfacial layers by ellipsometry , 2001 .

[12]  T. Horbett,et al.  Proteins at interfaces : physicochemical and biochemical studies , 1987 .

[13]  K. Najafi,et al.  Scaling limitations of silicon multichannel recording probes , 1990, IEEE Transactions on Biomedical Engineering.

[14]  A. Litke,et al.  The retinal readout array , 1991 .

[15]  K. Najafi,et al.  Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays , 1992, Brain Research.

[16]  Joseph D. Andrade,et al.  Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses , 1986 .

[17]  Surface examination of electrodes of removed implants. , 1988, Scandinavian journal of rehabilitation medicine. Supplement.

[18]  J. Keddie,et al.  Use of ellipsometry and gravimetry to develop calibration standards for measuring silicone coat weight and thickness with x‐ray fluorescence spectroscopy , 2000 .

[19]  D. Axelrod,et al.  Total internal reflection/fluorescence photobleaching recovery study of serum albumin adsorption dynamics. , 1981, Biophysical journal.

[20]  R. Azzam,et al.  Ellipsometry and polarized light , 1977 .

[21]  T. Horbett,et al.  Proteins at Interfaces II-Fundamentals and Applications- , 1995 .

[22]  V. Hlady,et al.  Protein adsorption on solid surfaces. , 1996, Current opinion in biotechnology.

[23]  J. Ong,et al.  Protein adsorption on titanium surfaces and their effect on osteoblast attachment. , 2003, Journal of biomedical materials research. Part A.

[24]  A. Gast,et al.  Lateral diffusion of bovine serum albumin adsorbed at the solid-liquid interface , 1990 .

[25]  Marcus Textor,et al.  A comparative study of protein adsorption on titanium oxide surfaces using in situ ellipsometry, optical waveguide lightmode spectroscopy, and quartz crystal microbalance/dissipation , 2002 .

[26]  P. Öberg,et al.  Long-term implantation of platinum electrodes: Effects on electrode material and nerve tissue , 1988, Medical and Biological Engineering and Computing.

[27]  David J. Edell,et al.  A Peripheral Nerve Information Transducer for Amputees: Long-Term Multichannel Recordings from Rabbit Peripheral Nerves , 1986, IEEE Transactions on Biomedical Engineering.

[28]  S. Thanos,et al.  Implantable bioelectronic interfaces for lost nerve functions , 1998, Progress in Neurobiology.

[29]  P. H. Lissberger,et al.  Ellipsometry and polarised light , 1977, Nature.

[30]  John L. Brash,et al.  Proteins at Interfaces: Current Issues and Future Prospects , 1987 .

[31]  K V Gopal,et al.  Auditory cortical neurons in vitro: cell culture and multichannel extracellular recording. , 1996, Acta oto-laryngologica.

[32]  Y. Jimbo,et al.  Electrical stimulation and recording from cultured neurons using a planar electrode array , 1992 .

[33]  P. H. Peckham,et al.  Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculature , 2006, Annals of Biomedical Engineering.

[34]  F. Rahemtulla,et al.  Proteoglycans at the bone-implant interface. , 1998, Critical reviews in oral biology and medicine : an official publication of the American Association of Oral Biologists.

[35]  R. Normann,et al.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.

[36]  C. Velde,et al.  A-Accelerators Spectrometers Detectors and Associated Equipment , 2002 .

[37]  David J. Anderson,et al.  Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording , 1986, IEEE Transactions on Biomedical Engineering.

[38]  K. Wise,et al.  A 64-site multishank CMOS low-profile neural stimulating probe , 1996, IEEE J. Solid State Circuits.

[39]  D. Williams,et al.  Protein absorption and desorption phenomena on clean metal surfaces. , 1985, Journal of biomedical materials research.