Real-Time Blood Velocity Vector Measurement Over a 2-D Region

Quantitative blood velocity measurements, as currently implemented in commercial ultrasound scanners, are based on pulsed-wave (PW) spectral Doppler and are limited to detect the axial component of the velocity in a single sample volume. On the other hand, vector Doppler methods produce angle-independent estimates by, e.g., combining the frequency shifts measured from different directions. Moreover, thanks to the transmission of plane waves, the investigation of a 2-D region is possible with high temporal resolution, but, unfortunately, the clinical use of these methods is hampered by the massive calculation power required for their real-time execution. In this paper, we present a novel approach based on the transmission of plane waves and the simultaneous reception of echoes from 16 distinct subapertures of a linear array probe, which produces eight lines distributed over a 2-D region. The method was implemented on the ULAO-OP 256 research scanner and tested both in phantom and in vivo. A continuous real-time refresh rate of 36 Hz was achieved in duplex combination with a standard B-mode at pulse repetition frequency of 8 kHz. Accuracies of −11% on velocity and of 2°on angle measurements have been obtained in phantom experiments. Accompanying movies show how the method improves the quantitative measurements of blood velocities and details the flow configurations in the carotid artery of a volunteer.

[1]  Billy Y S Yiu,et al.  Vector projectile imaging: time-resolved dynamic visualization of complex flow patterns. , 2014, Ultrasound in medicine & biology.

[2]  Piero Tortoli,et al.  Simultaneous ultrasound assessment of brachial artery shear stimulus and flow-mediated dilation during reactive hyperemia. , 2011, Ultrasound in medicine & biology.

[3]  Lasse Lovstakken,et al.  Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking. , 2014, Ultrasound in medicine & biology.

[4]  Billy Y S Yiu,et al.  Least-Squares Multi-Angle Doppler Estimators for Plane-Wave Vector Flow Imaging. , 2016, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[5]  M. Nielsen,et al.  Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas. , 2016, Ultrasonics.

[6]  J. Jensen,et al.  A new method for estimation of velocity vectors , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Mickael Tanter,et al.  Ultrafast imaging in biomedical ultrasound , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[8]  A. Dallai,et al.  A reconfigurable and programmable FPGA-based system for nonstandard ultrasound methods , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  R Eugene Zierler,et al.  Carotid artery stenosis: gray-scale and Doppler US diagnosis--Society of Radiologists in Ultrasound Consensus Conference. , 2003, Radiology.

[10]  Piero Tortoli,et al.  Accurate blood peak velocity estimation using spectral models and vector doppler , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[11]  Piero Tortoli,et al.  Accuracy and reproducibility of a novel dynamic volume flow measurement method. , 2013, Ultrasound in medicine & biology.

[12]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[13]  H. Torp,et al.  Ultrasound simulation of complex flow velocity fields based on computational fluid dynamics , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Hiroshi Kanai,et al.  Echo speckle imaging of blood particles with high-frame-rate echocardiography , 2014 .

[15]  Piero Tortoli,et al.  Wall Shear Rate Measurement: Validation of a New Method Through Multiphysics Simulations , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[16]  S. Diciotti,et al.  Accuracy and reproducibility of a novel dual-beam vector Doppler method. , 2009, Ultrasound in medicine & biology.

[17]  Damien Garcia,et al.  Ultrasound Vector Flow Imaging: II: Parallel Systems. , 2016, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[18]  Richard S C Cobbold,et al.  Human factors as a source of error in peak Doppler velocity measurement. , 2005, Journal of vascular surgery.

[19]  Lucia Francesca Lucca,et al.  Wall shear stress is lower in the carotid artery responsible for a unilateral ischemic stroke. , 2006, Atherosclerosis.

[20]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[21]  Damien Garcia,et al.  Ultrasound Vector Flow Imaging—Part I: Sequential Systems , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[22]  Piero Tortoli,et al.  Plane-wave transverse oscillation for high-frame-rate 2-D vector flow imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[23]  M. Lewandowski,et al.  Optimization of real-time ultrasound PCIe data streaming and OpenCL processing for SAFT imaging , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[24]  Ingvild Kinn Ekroll,et al.  Robust angle-independent blood velocity estimation based on dual-angle plane wave imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[25]  P. Tortoli,et al.  An automatic angle tracking procedure for feasible vector Doppler blood velocity measurements. , 2010, Ultrasound in medicine & biology.

[26]  J. Kortbek,et al.  Estimation of velocity vector angles using the directional cross-correlation method , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  S. Ricci,et al.  Adaptive spectral estimators for fast flow-profile detection , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  P. Fish,et al.  Velocity bias and fluctuation in the standard dual beam Doppler reconstruction algorithm , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  B. Y. S. Yiu,et al.  GPU-based beamformer: Fast realization of plane wave compounding and synthetic aperture imaging , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  Piero Tortoli,et al.  Real-time vector velocity assessment through multigate doppler and plane waves , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[32]  P. Tortoli,et al.  Multi-line measurements of blood velocity vectors in real-time , 2016, 2016 IEEE International Ultrasonics Symposium (IUS).

[33]  P. Tortoli,et al.  Accurate Doppler angle estimation for vector flow measurements , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  Piero Tortoli,et al.  Clinical validation of common carotid artery wall distension assessment based on multigate Doppler processing. , 2005, Ultrasound in medicine & biology.

[35]  Herve Liebgott,et al.  2-D arterial wall motion imaging using ultrafast ultrasound and transverse oscillations , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[36]  L.N. Bohs,et al.  A novel method for angle independent ultrasonic imaging of blood flow and tissue motion , 1991, IEEE Transactions on Biomedical Engineering.

[37]  Marcel C M Rutten,et al.  Toward noninvasive blood pressure assessment in arteries by using ultrasound. , 2011, Ultrasound in medicine & biology.

[38]  Piero Tortoli,et al.  Architecture of an Ultrasound System for Continuous Real-Time High Frame Rate Imaging , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[39]  Piero Tortoli,et al.  Comparison of carotid artery blood velocity measurements by vector and standard Doppler approaches. , 2015, Ultrasound in medicine & biology.

[40]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  Piero Tortoli,et al.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[42]  M. Fox Multiple crossed-beam ultrasound Doppler velocimetry , 1978 .