Long-term performance of air-side heat transfer and pressure drop for finned tube evaporators of air conditioners under intermittent operation conditions

Abstract In this study, the effects of long-term intermittent operations on the air-side heat transfer and pressure drop performance of finned tube evaporators of air conditioners were investigated by experiments on an aluminum-fin evaporator and a copper-fin evaporator. In order to simulate intermittent operations of on–off controlled air conditioners, the temperatures of the two evaporators changed to 5 ± 0.5 °C at first and then to 27 ± 0.5 °C repeatedly. The repetition number was up to 4800, and the air-side heat transfer and pressure drop of the two evaporators were tested after every 300 repetitions. The test results indicate that after long-term intermittent operations, the air-side heat transfer coefficient decreases and the pressure drop increases. The variations of the heat transfer coefficient and the pressure drop are more obvious at lower inlet air velocity, and the influence of long-term intermittent operations on the aluminum-fin evaporator is greater than that on the copper-fin evaporator.

[1]  R. Webb,et al.  Long-term wetting and corrosion characteristics of hot water treated aluminum and copper fin stocks , 2002 .

[2]  Guoliang Ding,et al.  Effects of biofouling on air-side heat transfer and pressure drop for finned tube heat exchangers , 2009 .

[3]  A. London,et al.  Compact heat exchangers , 1960 .

[4]  V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flow , 1976 .

[5]  Robert J. Moffat,et al.  Describing the Uncertainties in Experimental Results , 1988 .

[6]  James E. Braun,et al.  The impact of fouling on the performance of filter–evaporator combinations , 2007 .

[7]  R. Webb,et al.  Long-Term Hydraulic Performance of Dehumidifying Heat-Exchangers With and Without Hydrophilic Coatings , 2000 .

[8]  Chi-Chuan Wang,et al.  Performance of plate finned tube heat exchangers under dehumidifying conditions , 1997 .

[9]  G. Ding,et al.  Effects of hydrophilic coating on air side heat transfer and friction characteristics of wavy fin and tube heat exchangers under dehumidifying conditions , 2007 .

[10]  R. Webb,et al.  Plasma hydrophilic surface treatment for dehumidifying heat exchangers , 2002 .

[11]  Chang Nyung Kim,et al.  A study on the thermal contact conductance in fin–tube heat exchangers with 7 mm tube , 2006 .

[12]  Chang Nyung Kim,et al.  A study on the correlation between the thermal contact conductance and effective factors in fin–tube heat exchangers with 9.52 mm tube , 2004 .

[13]  Guoliang Ding,et al.  Airside heat transfer and friction characteristics for enhanced fin-and-tube heat exchanger with hydrophilic coating under wet conditions , 2007 .