Functional phase-correlated micro-CT imaging of small rodents with low dose

Functional imaging of an animals thoracic region requires cardiac and respiratory gating. The information on respiratory motion and ECG required for double-gating are extracted from the rawdata and used to select the projections appropriate for a given motion phase. A conventional phase-correlated reconstruction (PC) therefore uses only a small amount of the total projections acquired. Thus the resulting images comprise a high noise level unless acquired with very high dose, and streak artifacts may occur due to the sparse angular sampling. Here, we are aiming at getting high fidelity images even for relatively low dose values. To overcome these issues we implemented an iterative reconstruction method encompassing a five-dimensional (spatial, cardiac-temporal, respiratory-temporal) edge-preserving filter. This new phase-correlated low-dose (LDPC) reconstruction method is evaluated using retrospectively-gated, contrast-enhanced micro CT data of mice. The scans performed comprise 7200 projections within 10 rotations over 5 minutes. A tube voltage of 65 kV was used resulting in an administered dose of about 500 mGy. 20 respiratory phases and 10 cardiac phases are reconstructed. Using LDPC reconstruction the image noise is typically reduced by a factor of about six and artifacts are almost removed. Reducing the number of projections available for reconstruction shows that we can get comparable image quality with only 200 mGy. LDPC enables high fidelity low-dose double-gated imaging of free breathing rodents without compromises in image quality. Compared to PC image noise is significantly reduced with LDPC and the administered dose can be reduced accordingly.

[1]  Wolfhard Semmler,et al.  Intrinsic respiratory gating in small-animal CT , 2008, European Radiology.

[2]  Graeme C. Mc Kinnon,et al.  Towards Imaging the Beating Heart Usefully with a Conventional CT Scanner , 1981, IEEE Transactions on Biomedical Engineering.

[3]  Wolfhard Semmler,et al.  Retrospective Motion Gating in Small Animal CT of Mice and Rats , 2007, Investigative radiology.

[4]  G Allan Johnson,et al.  4-D Micro-CT of the Mouse Heart , 2005, Molecular imaging.

[5]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[6]  Richard A. Robb,et al.  3-D Reconstruction of the Heart from Few Projections: A Practical Implementation of the McKinnon-Bates Algorithm , 1986, IEEE Transactions on Medical Imaging.

[7]  Roberto Manduchi,et al.  Bilateral filtering for gray and color images , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[8]  L. Hedlund,et al.  Micro-CT with respiratory and cardiac gating. , 2004, Medical physics.

[9]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[10]  Wolfhard Semmler,et al.  Intrinsic Gating for Small-Animal Computed Tomography: A Robust ECG-Less Paradigm for Deriving Cardiac Phase Information and Functional Imaging , 2008, Circulation. Cardiovascular imaging.

[11]  Maria Drangova,et al.  Fast Retrospectively Gated Quantitative Four-Dimensional (4D) Cardiac Micro Computed Tomography Imaging of Free-Breathing Mice , 2007, Investigative radiology.

[12]  Maria Drangova,et al.  Prospective respiratory-gated micro-CT of free breathing rodents. , 2005, Medical physics.