Imaging of current flow in the human head during transcranial electrical therapy

BACKGROUND It has been assumed that effects caused by tDCS or tACS neuromodulation are due to electric current flow within brain structures. However, to date, direct current density distributions in the brains of human subjects have not been measured. Instead computational models of tDCS or tACS have been used to predict electric current and field distributions for dosimetry and mechanism analysis purposes. OBJECTIVE/HYPOTHESIS We present the first in vivo images of electric current density distributions within the brain in four subjects undergoing transcranial electrical stimulation. METHODS Magnetic resonance electrical impedance tomography (MREIT) techniques encode current flow in phase images. In four human subjects, we used MREIT to measure magnetic flux density distributions caused by tACS currents, and then calculated current density distributions from these data. Computational models of magnetic flux and current distribution, constructed using contemporaneously collected T1-weighted structural MRI images, were co-registered to compare predicted and experimental results. RESULTS We found consistency between experimental and simulated magnetic flux and current density distributions using transtemporal (T7-T8) and anterior-posterior (Fpz-Oz) electrode montages, and also differences that may indicate a need to improve models to better interpret experimental results. While human subject data agreed with computational model predictions in overall scale, differences may result from factors such as effective electrode surface area and conductivities assumed in models. CONCLUSIONS We believe this method may be useful in improving reproducibility, assessing safety, and ultimately aiding understanding of mechanisms of action in electrical and magnetic neuromodulation modalities.

[1]  Eung Je Woo,et al.  Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging , 2008, Physiological measurement.

[2]  Abhishek Datta,et al.  Imaging artifacts induced by electrical stimulation during conventional fMRI of the brain , 2014, NeuroImage.

[3]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[4]  Eung Je Woo,et al.  Regional absolute conductivity reconstruction using projected current density in MREIT , 2012, Physics in medicine and biology.

[5]  N. Wenderoth,et al.  A technical guide to tDCS, and related non-invasive brain stimulation tools , 2016, Clinical Neurophysiology.

[6]  Walter Paulus,et al.  On the difficulties of separating retinal from cortical origins of phosphenes when using transcranial alternating current stimulation (tACS) , 2010, Clinical Neurophysiology.

[7]  Byung Il Lee,et al.  Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths. , 2005, Physiological measurement.

[8]  W. Sutherling,et al.  Conductivities of Three-Layer Live Human Skull , 2004, Brain Topography.

[9]  R. C. Oldfield The assessment and analysis of handedness: the Edinburgh inventory. , 1971, Neuropsychologia.

[10]  S. Folstein,et al.  "Mini-mental state". A practical method for grading the cognitive state of patients for the clinician. , 1975, Journal of psychiatric research.

[11]  Kay Jann,et al.  In-vivo Imaging of Magnetic Fields Induced by Transcranial Direct Current Stimulation (tDCS) in Human Brain using MRI , 2016, Scientific Reports.

[12]  David R. Wozny,et al.  The electrical conductivity of human cerebrospinal fluid at body temperature , 1997, IEEE Transactions on Biomedical Engineering.

[13]  Ohin Kwon,et al.  Current Density Imaging Using Directly Measured Harmonic B z Data in MREIT , 2013, Comput. Math. Methods Medicine.

[14]  S. Schoenberg,et al.  Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters , 2007, Journal of magnetic resonance imaging : JMRI.

[15]  M. Nitsche,et al.  Physiological Basis of Transcranial Direct Current Stimulation , 2011, The Neuroscientist : a review journal bringing neurobiology, neurology and psychiatry.

[16]  W. C. Jeong,et al.  Noise analysis in fast magnetic resonance electrical impedance tomography (MREIT) based on spoiled multi gradient echo (SPMGE) pulse sequence. , 2014, Physics in medicine and biology.

[17]  Walter Paulus,et al.  Combining functional magnetic resonance imaging with transcranial electrical stimulation , 2013, Front. Hum. Neurosci..

[18]  Dennis J. L. G. Schutter,et al.  Retinal origin of phosphenes to transcranial alternating current stimulation , 2010, Clinical Neurophysiology.

[19]  H. Möller,et al.  Prefrontal Transcranial Direct Current Stimulation Changes Connectivity of Resting-State Networks during fMRI , 2011, The Journal of Neuroscience.

[20]  Eung Je Woo,et al.  Ramp-Preserving Denoising for Conductivity Image Reconstruction in Magnetic Resonance Electrical Impedance Tomography , 2011, IEEE Transactions on Biomedical Engineering.

[21]  Eung Je Woo,et al.  Electrical Tissue Property Imaging at Low Frequency Using MREIT , 2014, IEEE Transactions on Biomedical Engineering.

[22]  L. Cohen,et al.  Transcranial direct current stimulation: State of the art 2008 , 2008, Brain Stimulation.

[23]  P. Å. Öberg,et al.  Magneto- and electrophosphenes: A comparative study , 1980, Medical and Biological Engineering and Computing.

[24]  Min Ho Chun,et al.  Modulation of cortical activity after anodal transcranial direct current stimulation of the lower limb motor cortex: A functional MRI study , 2012, Brain Stimulation.

[25]  R. Sadleir,et al.  Multishot echo‐planar MREIT for fast imaging of conductivity, current density, and electric field distributions , 2017, Magnetic resonance in medicine.

[26]  Roberto Viviani,et al.  A Digital Atlas of Middle to Large Brain Vessels and Their Relation to Cortical and Subcortical Structures , 2016, Front. Neuroanat..

[27]  Gang Chen,et al.  MREIT with SENSE acceleration using a dedicated RF coil design , 2009, Physiological measurement.

[28]  R. Sadleir,et al.  Predicted current densities in the brain during transcranial electrical stimulation , 2006, Clinical Neurophysiology.

[29]  Ohin Kwon,et al.  Current Density Imaging During Transcranial Direct Current Stimulation Using DT-MRI and MREIT: Algorithm Development and Numerical Simulations , 2016, IEEE Transactions on Biomedical Engineering.

[30]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[31]  L. Parra,et al.  Effects of weak transcranial alternating current stimulation on brain activity—a review of known mechanisms from animal studies , 2013, Front. Hum. Neurosci..

[32]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[33]  Chunjae Park,et al.  Non-iterative conductivity reconstruction algorithm using projected current density in MREIT. , 2008, Physics in medicine and biology.

[34]  D. Sodickson,et al.  A generalized approach to parallel magnetic resonance imaging. , 2001, Medical physics.

[35]  M. Nitsche,et al.  Partially non‐linear stimulation intensity‐dependent effects of direct current stimulation on motor cortex excitability in humans , 2013, The Journal of physiology.

[36]  Stephen M. Smith,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[37]  Byung Il Lee,et al.  Analysis of recoverable current from one component of magnetic flux density in MREIT and MRCDI , 2007, Physics in medicine and biology.

[38]  Rosalind J. Sadleir,et al.  Transcranial direct current stimulation (tDCS) in a realistic head model , 2010, NeuroImage.

[39]  M. Nitsche,et al.  Safety of Transcranial Direct Current Stimulation: Evidence Based Update 2016 , 2016, Brain Stimulation.

[40]  Alexander Opitz,et al.  Spatiotemporal structure of intracranial electric fields induced by transcranial electric stimulation in humans and nonhuman primates , 2016, Scientific Reports.