A Resonant Vibrating Tactile Probe for Biomedical Applications Based on IPMC

In this paper, a vibrating tactile probe is presented. The probe exploits the dependence of its resonant frequency on the varying load and hence on the contacted material. This methodology allows the recognition of different materials by observing the electrical quantities involved in the probe dynamics. More specifically, two ionic polymer-metal composite (IPMC) strips are used, one as actuator and one as sensor, that work together for the recognition of materials. The actuator forces the system into resonant conditions that, as stated before, change with the mechanical properties of the contacted material. The output signal produced by the IPMC sensor contains the information required for the estimation of the contacting material. The sensing capabilities could be exploited in various biomedical applications, such as catheterism and surgical resection of tumors. The model and the experimental validation of the proposed probe are reported. For each material, different surveys were collected to estimate the uncertainty of the resonant frequency and hence to obtain the characteristic diagram of the device along with its uncertainty. The reported results show that the developed probe can be used to distinguish among different materials.

[1]  Kwang J. Kim,et al.  An Equivalent Circuit Model for Ionic Polymer-Metal Composites and their Performance Improvement by a Clay-Based Polymer Nano-Composite Technique , 2003 .

[2]  Jörg Wallaschek,et al.  Resonant vibrating sensors for tactile tissue differentiation , 2007 .

[3]  Rong-Fong Fung,et al.  Quantitative determination of material viscoelasticity using a piezoelectric cantilever bimorph beam , 2006 .

[4]  K. Khosraviani,et al.  The nanogap pirani - a pressure sensor with superior linearity in atmospheric pressure range , 2008, 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems.

[5]  Robert J. Wood,et al.  Nonlinear Performance Limits for High Energy Density Piezoelectric Bending Actuators , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[6]  Luigi Fortuna,et al.  A nonlinear model for ionic polymer metal composites as actuators , 2007 .

[7]  T. Krouskop,et al.  Elastic Moduli of Breast and Prostate Tissues under Compression , 1998, Ultrasonic imaging.

[8]  Donald J. Leo,et al.  Electromechanical Modeling and Characterization of Ionic Polymer Benders , 2002 .

[9]  K. Kim,et al.  Ionic polymer–metal composites: IV. Industrial and medical applications , 2005 .

[10]  Stewart Sherrit,et al.  An ultrasonic sampler and sensor platform for in situ astrobiological exploration , 2003, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[11]  Luigi Fortuna,et al.  A model for ionic polymer metal composites as sensors , 2006 .

[12]  K. Kim,et al.  Ionic polymer-metal composites: I. Fundamentals , 2001 .

[13]  S. Graziani,et al.  A Tactile Sensor for Biomedical Applications Based on IPMCs , 2008, IEEE Sensors Journal.

[14]  T. Takamori,et al.  Linear approximate dynamic model of ICPF (ionic conducting polymer gel film) actuator , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[15]  Sia Nemat-Nasser,et al.  Electromechanical response of ionic polymer-metal composites , 2000 .

[16]  M. Brokelmann,et al.  Bond process monitoring via self-sensing piezoelectric transducers , 2004, Proceedings of the 2004 IEEE International Frequency Control Symposium and Exposition, 2004..

[17]  Luigi Fortuna,et al.  A resonant force sensor based on ionic polymer metal composites , 2008 .

[18]  Per G. Reinhall,et al.  Analysis of electro-active polymer bending: A component in a low cost ultrathin scanning endoscope , 2007 .

[19]  J. Franklin,et al.  Electromechanical Modeling of Encapsulated Ionic Polymer Transducers , 2003 .

[20]  Toshi Takamori,et al.  A dynamic model of ICPF actuator considering ion-induced lateral strain for molluskan robotics , 2002, IEEE/RSJ International Conference on Intelligent Robots and Systems.

[21]  Toshi Takamori,et al.  An actuator model of ICPF for robotic applications on the basis of physicochemical hypotheses , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[22]  Luigi Fortuna,et al.  A bio-inspired device to detect equilibrium variations using IPMCs and ferrofluids , 2008 .