A Voltage and Frequency Controller for Self-Excited Induction Generators

This article describes a controller for voltage and frequency control of self-excited induction generator (SEIG) supplying static/dynamic, balanced/unbalanced loads. The controller is a combination of a three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC-VSI) and a high frequency DC chopper, which keeps the generated voltage and frequency constant in spite of change in consumer loads. A mathematical model of the SEIG with this controller supplying different types of loads is developed for predicting the behavior of the system under transient and dynamic conditions. The simulated results show that generated frequency and voltage remain constant with change in load. The proposed controller acts as reactive power compensator, harmonic eliminator, load balancer, and frequency and voltage regulator.

[1]  Bhim Singh,et al.  Analysis of a novel solid state voltage regulator for a self-excited induction generator , 1998 .

[2]  S. S. Murthy,et al.  Experience in the development of microhydel grid independent power generation scheme using induction generators for Indian conditions , 1998, Proceedings of IEEE TENCON '98. IEEE Region 10 International Conference on Global Connectivity in Energy, Computer, Communication and Control (Cat. No.98CH36229).

[3]  M. S. Miranda,et al.  An alternative isolated wind electric pumping system using induction machines , 1999 .

[4]  Bhim Singh,et al.  Transient Analysis of Self-Excited Induction Generator Supplying Dynamic Load , 1999 .

[5]  Saad Alghuwainem Steady-state analysis of an isolated self-excited induction generator driven by regulated and unregulated turbine , 1999 .

[6]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[7]  R. Bonert,et al.  A technique for the steady-state analysis of a self-excited induction generator with variable speed , 1993 .

[8]  Li Wang,et al.  Dynamic analyses of parallel operated self-excited induction generators feeding an induction motor load , 1999 .

[9]  T. F. Chan,et al.  Capacitance requirements of self-excited induction generators , 1993 .

[10]  B. P. Singh,et al.  Analysis of self excited induction generator feeding induction motor , 1994 .

[11]  Jose Antenor Pomilio,et al.  Self-excited induction generator controlled by a VS-PWM bi-directional converter for rural applications , 1998, APEC '98 Thirteenth Annual Applied Power Electronics Conference and Exposition.

[12]  Jose Antenor Pomilio,et al.  Self-excited induction generator controlled by a VS-PWM bidirectional converter for rural applications , 1999 .

[13]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[14]  Li Wang,et al.  Long-shunt and short-shunt connections on dynamic performance of a SEIG feeding an induction motor load , 2000 .

[15]  P. G. Holmes,et al.  Transient and steady-state load performance of a stand-alone self-excited induction generator , 1996 .

[16]  P. Vas,et al.  The analysis of a saturated self-excited asynchronous generator , 1991 .

[17]  Sanjay Kumar Jain,et al.  Transient performance of three-phase self-excited induction generator during balanced and unbalanced faults , 2002 .

[18]  R. Bonert,et al.  Self-excited induction generator with excellent voltage and frequency control , 1998 .

[19]  O. P. Malik,et al.  Analysis of self-excited induction generators , 1982 .

[20]  Danny Sutanto,et al.  Steady-state and transient analysis of self-excited induction generators , 1989 .

[21]  D. Henderson,et al.  AN ADVANCED ELECTRONIC LOAD GOVERNOR FOR CONTROL OF MICRO HYDROELECTRIC GENERATION , 1996, Proceedings of International Conference on Power Electronics, Drives and Energy Systems for Industrial Growth.

[22]  M. B. Brennen,et al.  Static Exciters for Induction Generators , 1977, IEEE Transactions on Industry Applications.