Testing a Method for Quantifying the Output of Implantable Middle Ear Hearing Devices

This report describes tests of a standard practice for quantifying the performance of implantable middle ear hearing devices (also known as implantable hearing aids). The standard and these tests were initiated by the Food and Drug Administration of the United States Government. The tests involved measurements on two hearing devices, one commercially available and the other home built, that were implanted into ears removed from human cadavers. The tests were conducted to investigate the utility of the practice and its outcome measures: the equivalent ear canal sound pressure transfer function that relates electrically driven middle ear velocities to the equivalent sound pressure needed to produce those velocities, and the maximum effective ear canal sound pressure. The practice calls for measurements in cadaveric ears in order to account for the varied anatomy and function of different human middle ears.

[1]  M. Kringlebotn,et al.  Frequency characteristics of the middle ear. , 1985, The Journal of the Acoustical Society of America.

[2]  R. Goode,et al.  Effect of Changes in Mass on Middle Ear Function , 1993, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[3]  Sunil Puria,et al.  Human middle-ear sound transfer function and cochlear input impedance , 2001, Hearing Research.

[4]  L W Lee,et al.  Evaluating performance with high-frequency emphasis amplification. , 1993, Journal of the American Academy of Audiology.

[5]  A. Huber,et al.  Analysis of the best site on the stapes footplate for ossicular chain reconstruction. , 1999, Acta Oto-Laryngologica.

[6]  John J. Rosowski,et al.  Acoustic responses of the human middle ear , 2000, Hearing Research.

[7]  R. Goode,et al.  Sound Pressure Gain Produced by the Human Middle Ear , 1995, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[8]  Rong Z. Gan,et al.  Mass Loading on the Ossicles and Middle Ear Function , 2001, The Annals of otology, rhinology, and laryngology.

[9]  Saumil N Merchant,et al.  A normative study of tympanic membrane motion in humans using a laser Doppler vibrometer (LDV) , 2004, Hearing Research.

[10]  K Gyo,et al.  Effect of middle ear pressure change on middle ear mechanics. , 1997, Acta oto-laryngologica.

[11]  Thomas J. Lynch Signal processing by the cat middle ear: admittance and transmission, measurements and models , 1981 .

[12]  K Gyo,et al.  Measurement of the ossicular vibration ratio in human temporal bones by use of a video measuring system. , 1987, Acta oto-laryngologica.

[13]  J. Suzuki Middle ear implant : implantable hearing aids , 1988 .

[14]  J. Ito,et al.  Suppression of tinnitus by cochlear implantation. , 1994, American journal of otolaryngology.

[15]  Stefan Stenfelt,et al.  Three-Dimensional Stapes Footplate Motion in Human Temporal Bones , 2003, Audiology and Neurotology.

[16]  K Nakamura,et al.  New knowledge about the function of the human middle ear: development of an improved analog model. , 1994, The American journal of otology.

[17]  D E Hayes,et al.  Double blind comparison of three hearing aid circuits with new hearing aid users , 2000, Scandinavian audiology.

[18]  Stefan Stenfelt,et al.  Acoustic Role of the Buttress and Posterior Incudal Ligament in Human Temporal Bones , 2001, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[19]  Harold F. Schuknecht,et al.  Pathology of the Ear , 1974 .

[20]  John J. Rosowski,et al.  The Effect of Methodological Differences in the Measurement of Stapes Motion in Live and Cadaver Ears , 2006, Audiology and Neurotology.