An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range.

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

[1]  Garth J. Williams,et al.  Lensless imaging using broadband X-ray sources , 2011 .

[2]  Garth J. Williams,et al.  Mapping Granular Structure in the Biological Adhesive of Phragmatopoma Californica Using Phase Diverse Coherent Diffractive Imaging Ultramicroscopy , 2022 .

[3]  Ian McNulty,et al.  Dynamic sample imaging in coherent diffractive imaging. , 2011, Optics letters.

[4]  David J Vine,et al.  Phase-diverse coherent diffractive imaging: high sensitivity with low dose. , 2011, Physical review letters.

[5]  H. Quiney Coherent diffractive imaging using short wavelength light sources , 2010 .

[6]  K. Nugent,et al.  Fresnel coherent diffraction tomography. , 2010, Optics express.

[7]  Keith A. Nugent,et al.  Fresnel coherent diffractive imaging: treatment and analysis of data , 2010 .

[8]  K A Nugent,et al.  Use of a complex constraint in coherent diffractive imaging. , 2010, Optics express.

[9]  K. Nugent Coherent methods in the X-ray sciences , 2009, 0908.3064.

[10]  K. Nugent,et al.  Diffractive imaging using partially coherent x rays. , 2009, Physical review letters.

[11]  Keith A. Nugent,et al.  Ptychographic Fresnel Coherent Diffractive Imaging , 2009 .

[12]  O. Bunk,et al.  High-Resolution Scanning X-ray Diffraction Microscopy , 2008, Science.

[13]  S. Vogt,et al.  Design and test of a differential scanning stage system for an x-ray nanoprobe instrument , 2005, SPIE Optics + Photonics.

[14]  H M L Faulkner,et al.  Error tolerance of an iterative phase retrieval algorithm for moveable illumination microscopy. , 2005, Ultramicroscopy.

[15]  R. Stewart,et al.  The tube cement of Phragmatopoma californica: a solid foam , 2004, Journal of Experimental Biology.

[16]  I. Robinson,et al.  Reconstruction of the shapes of gold nanocrystals using coherent x-ray diffraction. , 2001, Physical review letters.

[17]  Charles Wang Laser vector measurement technique for the determination and compensation of volumetric positioning errors. Part I: Basic theory , 2000 .

[18]  Deming Shu,et al.  Modular overconstrained weak-link mechanism for ultraprecision motion control , 2000 .

[19]  J. Miao,et al.  Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens , 1999, Nature.

[20]  J. Miao,et al.  Phase retrieval from the magnitude of the Fourier transforms of nonperiodic objects , 1998 .

[21]  Ali M. Khounsary,et al.  A beamline for 1–4 keV microscopy and coherence experiments at the Advanced Photon Source , 1996 .