The feasibility of measuring three-dimensional facial morphology in children.

OBJECTIVE An investigation to determine the feasibility of measuring soft tissue morphology in children using a three-dimensional laser-scanning device. DESIGN Prospective clinical trial. SETTING AND SAMPLE POPULATION University of Wales, College of Medicine and one secondary school in the South Wales region. Sixty live subjects (30 adults, 30 children) were recruited in the study. EXPERIMENTAL VARIABLES Laser scanned images of the subjects were obtained under a reproducible and controlled environment with two Minolta Vivid 900 (Osaka, Japan) optical laser-scanning devices assembled as a stereo-pair. A set of left and right scanned images was taken for each subject and each scan took an average of 2.5 s. These scanned images were processed and merged to form a composite three-dimensional soft tissue reproduction of the subjects using commercially available reverse modelling software. OUTCOME MEASURE The shell deviations between left and right scan of each patient were recorded and analysed for differences. These differences determined whether the subjects could remain still during the time of the scans. RESULTS The results showed that the mean differences between shell deviations for the adult scans and children scans were 0.25 +/- 0.09 and 0.30 +/- 0.09 mm, respectively. Paired t-tests showed that the mean error between subject groups was 0.05 +/- 0.15 mm indicating that there was no difference between the two subject groups (p = 0.18). CONCLUSION The technique as described is clinically reproducible for children and adults and can be used for studies assessing facial changes due to growth or clinical intervention.

[1]  B. Kusnoto,et al.  Reliability of a 3D surface laser scanner for orthodontic applications. , 2002, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[2]  R Enciso,et al.  Three-dimensional visualization of the craniofacial patient: volume segmentation, data integration and animation. , 2003, Orthodontics & craniofacial research.

[3]  S. C. Aung,et al.  Evaluation of the laser scanner as a surface measuring tool and its accuracy compared with direct facial anthropometric measurements. , 1995, British journal of plastic surgery.

[4]  R. Clark,et al.  Reproducibility of natural head position. , 1991, Journal of dentistry.

[5]  A D Linney,et al.  A three-dimensional soft tissue analysis of 16 skeletal class III patients following bimaxillary surgery. , 1992, The British journal of oral & maxillofacial surgery.

[6]  Joachim Mühling,et al.  Laser-scan-based navigation in cranio-maxillofacial surgery. , 2003, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[7]  T. Coward,et al.  Laser scanning for the identification of repeatable landmarks of the ears and face. , 1997, British journal of plastic surgery.

[8]  Orhan C. Tuncay,et al.  Three-dimensional imaging of the craniofacial complex. , 2000, Clinical orthodontics and research.

[9]  Ulrich Neumann,et al.  The virtual craniofacial patient: 3D jaw modeling and animation. , 2003, Studies in health technology and informatics.

[10]  C. A. Hood,et al.  Validation of a Vision-Based, Three-Dimensional Facial Imaging System , 2003, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.

[11]  S R Arridge,et al.  Three-dimensional visualization of the face and skull using computerized tomography and laser scanning techniques. , 1987, European Journal of Orthodontics.