Powerline Communication in Home-Building Automation Systems

Domotics, Smart Home Systems, Ambient Intelligence are all terms that describe the intelligent cooperation of several different equipments to manage the home environment in an intelligent, safe and comfortable way. The same idea is also applicable to bigger constructions, and in that case it takes the name of Building Automation. Whatever term one wants to use, it refers to a multidisciplinary field that includes informatics, electronics, automation and telecommunication, and also touches fields like building constructions and architecture. In fact, during the process of designing a building, people have to consider appropriate spaces for the electric plant, and if the presence of a domotic system is planned, it is better to take it into account during the design phase, just to optimize spaces, the amount of used wires, the position of the modules and so on. There are really many home system producers in the world (Smart Home Systems, EIBKonnex, Lonworks, Bticino, Vimar, Duemmegi, EasyDom Corporation, Futurware, Digital Cybermasters, Hills Home Systems, Intellihome etc, just to mention a few), and their products differ from each others in many characteristics, such as functionality, dimension, weight, typology of installation, materials, net topology, power consumes, aesthetic appearance, communication protocol and communication mean. Regarding this last point, the majority of the domotic systems, especially in Europe, tend to use a dedicated bus cable to exchange data among modules, to make the communication link more robust and reliable. Lately, using radio communication is in fashion, but radio modules, respect to their equivalent standard ones, are more expensive, and in the bargain many people don’t want to use them due to the fear of radio signals (even if it were proved that they are completely harmless). Another communication mean, that is often not taken into account, is the powerline. In point of fact, using the installed poweline wires to send information is a very smart idea: there is no additional cost to install other dozens of meters of wires, there is not the necessity to break the walls and to do building works at home, there are no interferences with other devices (like in the radio communication case) or reflection problems (like in the infrared case), there is the possibility to put the modules in every place (it is sufficient to have an electrical socket in the nearness, or to use an extension cable), there is no need to have an extra power source (usually, in a bus cable domotic system, there is a direct voltage generated by a power supply and distribuited on the whole domotic net).

[1]  Chris Davison No new wires , 2008, CIE.

[2]  A.J.H. Vinck,et al.  Coded M-FSK for power line communications , 2000, 2000 IEEE International Symposium on Information Theory (Cat. No.00CH37060).

[3]  Srinivas Katar,et al.  A power line communication network infrastructure for the smart home , 2002, IEEE Wirel. Commun..

[4]  Matthias Götz,et al.  Power line channel characteristics and their effect on communication system design , 2004, IEEE Communications Magazine.

[5]  Srinivas Katar,et al.  A comparative performance study of wireless and power line networks , 2003, IEEE Commun. Mag..

[6]  I.H. Cavdar Performance analysis of FSK power line communications systems over time-varying channels: measurements and modeling , 2004, IEEE Power Engineering Society General Meeting, 2004..

[7]  I.H. Cavdar A solution to remote detection of illegal electricity usage via power line communications , 2004, IEEE Power Engineering Society General Meeting, 2004..

[8]  Elena Mainardi Design of a portable touchscreen interface for powerline domotic systems , 2008, 2008 IEEE International Conference on Automation Science and Engineering.

[9]  A.W.S. Brown,et al.  Interfacing modern technology to disabled patients , 1988 .

[10]  Daniel Pak-Kong Lun,et al.  Power-line communications using DWMT modulation , 2002, 2002 IEEE International Symposium on Circuits and Systems. Proceedings (Cat. No.02CH37353).

[11]  K. Dostert,et al.  Selection of an optimal modulation scheme for digital communications over low voltage power lines , 1996, Proceedings of ISSSTA'95 International Symposium on Spread Spectrum Techniques and Applications.

[12]  Roger Vines,et al.  Noise on Residential Power Distribution Circuits , 1984, IEEE Transactions on Electromagnetic Compatibility.

[13]  T. Waldeck,et al.  Comparison of modulation schemes with frequency agility for application in power line communication systems , 1996, Proceedings of ISSSTA'95 International Symposium on Spread Spectrum Techniques and Applications.

[14]  I.H. Cavdar Performance analysis of FSK power line communications systems over the time-varying channels: measurements and modeling , 2004, IEEE Transactions on Power Delivery.

[15]  Marie-Christine Bansse Comité européen de normalisation électrotechnique (CENELEC) , 1989 .

[16]  D.J. McFarland,et al.  The wadsworth BCI research and development program: at home with BCI , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  A. Bazant,et al.  Analysis of modulation methods for data communications over the low-voltage grid , 2003, Proceedings of the 7th International Conference on Telecommunications, 2003. ConTEL 2003..

[18]  TechnologiesAmit Dhir,et al.  Home Networking Using "No New Wires" Phoneline and Powerline Interconnection , 2001 .

[19]  Marcello Bonfe,et al.  A low-cost Home Automation System based on Power-Line Communication Links , 2005 .

[20]  Joong-Geun Rhee,et al.  Electromagnetic interferences caused by power line communications in the HF bands , 2008, 2008 IEEE International Symposium on Power Line Communications and Its Applications.

[21]  D. Hansen Update on power line telecommunication (PLT) activities in Europe , 2002, 2002 IEEE International Symposium on Electromagnetic Compatibility.