Long-term results of heart valve replacement with the Edwards Duromedics bileaflet prosthesis: a prospective ten-year clinical follow-up.
暂无分享,去创建一个
A. Moritz | E. Wolner | B. Podesser | E. Eigenbauer | S. Roedler | G. Khuenl-Brady | A. Schmiedberger | Gudrun Khuenl-Brady
[1] L. Cohn,et al. Guidelines for reporting morbidity and mortality after cardiac valvular operations. , 1996, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.
[2] E. Baudet,et al. A 8-year follow-up of the Edwards-Duromedics bileaflet prosthesis. , 1995, The Journal of cardiovascular surgery.
[3] G F Tyers,et al. Clinical performance of biological and mechanical prostheses. , 1995, The Annals of thoracic surgery.
[4] S. Aoyagi,et al. Long-term results of valve replacement with the St. Jude Medical valve. , 1994, The Journal of thoracic and cardiovascular surgery.
[5] Erickson Rl,et al. An in vitro study of mechanical heart valve sound loudness. , 1994 .
[6] M. Howanec,et al. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves. , 1994, The Journal of heart valve disease.
[7] F. R. Rosendaal,et al. Thromboembolic and Bleeding Complications in Patients With Mechanical Heart Valve Prostheses , 1994, Circulation.
[8] A. Moritz,et al. Doppler sonographic evaluation of the Duromedics-Edwards bileaflet valve at five-year follow up. , 1993, The Journal of heart valve disease.
[9] U. Steinseifer,et al. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves. , 1993, The Journal of thoracic and cardiovascular surgery.
[10] U. Steinseifer,et al. Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses. , 1992, British heart journal.
[11] W. Daggett,et al. Late results with Carpentier-Edwards porcine bioprosthesis. , 1990, Circulation.
[12] A. Moritz,et al. Four year follow-up of the Duromedics Edwards bileaflet valve prostheses. , 1990, The Journal of cardiovascular surgery.
[13] V. Björk,et al. Mechanical failure of the Björk-Shiley valve. Updated follow-up and considerations on prophylactic rereplacement. , 1986, The Journal of thoracic and cardiovascular surgery.
[14] B. Carabello,et al. Valvular Heart Disease , 2020, Clinical Small Animal Internal Medicine.
[15] A. Moritz,et al. Six-year follow-up after heart valve replacement with the Edwards Duromedics bileaflet prosthesis. , 1993, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.
[16] E Wolner,et al. Leaflet fracture in Edwards-Duromedics bileaflet valves. , 1989, The Journal of thoracic and cardiovascular surgery.