Detecting alterations of glucose and lipid components in human serum by near-infrared Raman spectroscopy

Introduction Raman spectroscopy may become a tool for the analysis of glucose and triglycerides in human serum in real time. This study aimed to detect spectral differences in lipid and glucose components of human serum, thus evaluating the feasibility of Raman spectroscopy for diagnostic purposes. Methods A total of 44 samples of blood serum were collected from volunteers and submitted for clinical blood biochemical analysis. The concentrations of glucose, cholesterol, triglycerides, and low-density and high-density lipoproteins (LDL and HDL) were obtained using standard biochemical assays. Serum samples were placed in Eppendorf tubes (200 µL), kept cooled (5 °C) and analyzed with near-infrared Raman spectroscopy (830 nm, 250 mW, 50 s accumulation). The mean spectra of serum with normal or altered concentrations of each parameter were compared to determine which Raman bands were related to the differences between these two groups. Results Differences in peak intensities of altered sera compared to normal ones depended on the parameter under analysis: for glucose, peaks were related to glucose; for lipid compounds the main changes occurred in the peaks related to cholesterol, lipids (mainly triolein) and proteins. Principal Components Analysis discriminated altered glucose, cholesterol and triglycerides from the normal serum based on the differences in the concentration of these compounds. Conclusion Differences in the peak intensities of selected Raman bands could be seen in normal and altered blood serum samples, and may be employed as a means of diagnosis in clinical analysis.

[1]  Richard W Morris,et al.  Metabolic syndrome vs Framingham Risk Score for prediction of coronary heart disease, stroke, and type 2 diabetes mellitus. , 2005, Archives of internal medicine.

[2]  P. Anzenbacher,et al.  Raman and IR spectroscopy in biology and biochemistry , 1994 .

[3]  H. Nakazawa,et al.  Validation of the Friedewald Equation for Evaluation of Plasma LDL-Cholesterol , 2007, Journal of clinical biochemistry and nutrition.

[4]  Landulfo Silveira,et al.  Correlating the amount of urea, creatinine, and glucose in urine from patients with diabetes mellitus and hypertension with the risk of developing renal lesions by means of Raman spectroscopy and principal component analysis , 2016, Journal of biomedical optics.

[5]  M. Feld,et al.  Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy. , 1997, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[6]  Mínistério da Saúde Cadernos de Atenção Básica: Carências de Micronutrientes , 2007 .

[7]  G. Puppels,et al.  Raman spectroscopy for quantifying cholesterol in intact coronary artery wall. , 1998, Atherosclerosis.

[8]  M. Hussain,et al.  Lipids and Dyslipoproteinemia , 2011 .

[9]  M. Akay,et al.  Biosignal pattern recognition and interpretation systems , 1993, IEEE Engineering in Medicine and Biology Magazine.

[10]  Andrew J Berger,et al.  Raman Spectroscopy-Based Creatinine Measurement in Urine Samples from a Multipatient Population , 2003, Applied spectroscopy.

[11]  C. Cordova,et al.  Determinação das glicemias capilar e venosa com glicosímetro versus dosagem laboratorial da glicose plasmática , 2009 .

[12]  S. Grundy,et al.  National Cholesterol Education Program Third Report of the National Cholesterol Education Program ( NCEP ) Expert Panel on Detection , Evaluation , and Treatment of High Blood Cholesterol in Adults ( Adult Treatment Panel III ) Final Report , 2022 .

[13]  H. Gremlich,et al.  Infrared and Raman Spectroscopy of Biological Materials , 2000 .

[14]  Renato Amaro Zângaro,et al.  Discriminating model for diagnosis of basal cell carcinoma and melanoma in vitro based on the Raman spectra of selected biochemicals , 2012, Journal of biomedical optics.

[15]  T C Bakker Schut,et al.  Raman Spectroscopic Evaluation of the Effects of Diet and Lipid-Lowering Therapy on Atherosclerotic Plaque Development in Mice , 2001, Arteriosclerosis, thrombosis, and vascular biology.

[16]  Landulfo Silveira,et al.  Correlation between near‐infrared Raman spectroscopy and the histopathological analysis of atherosclerosis in human coronary arteries , 2002, Lasers in surgery and medicine.

[17]  R. Dasari,et al.  Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation , 2012, PloS one.

[18]  A. Talari,et al.  Raman Spectroscopy of Biological Tissues , 2007 .

[19]  B. McManus,et al.  The Human Serum Metabolome , 2011, PloS one.

[20]  Hideo Tashiro,et al.  Intravascular Raman spectroscopic catheter for molecular diagnosis of atherosclerotic coronary disease. , 2006, Applied optics.

[21]  Renato Amaro Zângaro,et al.  Near Infrared Raman Spectroscopy (NIRS): A technique for doping control , 2006 .

[22]  M Fitzmaurice,et al.  Raman microspectroscopy of human coronary atherosclerosis: biochemical assessment of cellular and extracellular morphologic structures in situ. , 2001, Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology.

[23]  M. Akay,et al.  Biosignal pattern recognition and interpretation systems. 3. Methods of classification , 1994, IEEE Engineering in Medicine and Biology Magazine.

[24]  R. Dasari,et al.  Prospects for in vivo Raman spectroscopy , 2000 .

[25]  D. Chou,et al.  Clinical Diagnosis and Management by Laboratory Methods , 2001 .

[26]  M. Feld,et al.  Multicomponent blood analysis by near-infrared Raman spectroscopy. , 1999, Applied optics.

[27]  Landulfo Silveira,et al.  Identification of hepatitis C in human blood serum by near-infrared Raman spectroscopy , 2008 .

[28]  Jennifer G. Robinson,et al.  2013 ACC/AHA guideline on the treatment of blood cholesterol to reduce atherosclerotic cardiovascular risk in adults: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, Circulation.

[29]  M. Pacheco,et al.  Discrimination of basal cell carcinoma and melanoma from normal skin biopsies in vitro through Raman spectroscopy and principal component analysis. , 2012, Photomedicine and laser surgery.

[30]  Yukihiro Ozaki,et al.  Quantitative analysis of metabolites in urine using a highly precise, compact near-infrared Raman spectrometer , 1996 .

[31]  J Möcks,et al.  Comparison of mid-infrared and Raman spectroscopy in the quantitative analysis of serum. , 2005, Journal of biomedical optics.

[32]  R. Klein,et al.  The incidence of hypertension in insulin-dependent diabetes. , 1996, Archives of internal medicine.

[33]  Paul R. Carey,et al.  Biochemical Applications of Raman and Resonance Raman Spectroscopies , 1982 .

[34]  M. Pacheco,et al.  Differential diagnosis between experimental endophthalmitis and uveitis in vitreous with Raman spectroscopy and principal components analysis. , 2012, Journal of photochemistry and photobiology. B, Biology.

[35]  Christoph Krafft,et al.  Near infrared Raman spectra of human brain lipids. , 2005, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[36]  B. Psaty,et al.  2013 ACC/AHA guideline on the treatment of blood cholesterol: a fresh interpretation of old evidence. , 2014, JAMA.

[37]  R. Nesto,et al.  Diabetes and hypertension , 2007, Nature Clinical Practice Endocrinology &Metabolism.

[38]  M. Pacheco,et al.  Discrimination of non‐melanoma skin lesions from non‐tumor human skin tissues in vivo using Raman spectroscopy and multivariate statistics , 2015, Lasers in surgery and medicine.

[39]  Jingwei Shao,et al.  In Vivo Blood Glucose Quantification Using Raman Spectroscopy , 2012, PloS one.

[40]  A. Martin,et al.  Glicemical analysis of human blood serum using FT-Raman: a new approach. , 2012, Photomedicine and laser surgery.

[41]  Fernando Costa,et al.  Diagnosis and management of the metabolic syndrome: an American Heart Association/National Heart, Lung, and Blood Institute scientific statement. , 2006, Current opinion in cardiology.

[42]  J. Mckenney,et al.  Executive Summary of The Third Report of The National Cholesterol Education Program (NCEP) Expert Panel on Detection, Evaluation, And Treatment of High Blood Cholesterol In Adults (Adult Treatment Panel III). , 2001, JAMA.

[43]  R. Dasari,et al.  Raman spectroscopy-based sensitive and specific detection of glycated hemoglobin. , 2012, Analytical chemistry.

[44]  Andrew J Berger,et al.  Chemical concentration measurement in blood serum and urine samples using liquid-core optical fiber Raman spectroscopy. , 2007, Applied optics.

[45]  R. Dasari,et al.  Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements , 2011, Analytical and bioanalytical chemistry.

[46]  M. Pacheco,et al.  Differentiating normal and basal cell carcinoma human skin tissues in vitro using dispersive Raman spectroscopy: a comparison between principal components analysis and simplified biochemical models. , 2010, Photomedicine and laser surgery.