Cooling and Energy-Saving Performance of Different Green Wall Design: A Simulation Study of a Block

To mitigate the urban heat island (UHI) and release the low carbon potential of green walls, we analyzed the cooling and energy-saving performance of different green wall designs. Envi-met was applied as the main simulation tool, and a pedestrian street named Yuhou Street was selected as the study object. Four designs of walls were summarized and simulated, demonstrating the living wall system (LWS). Super soil had superiority in cooling and energy saving. Outdoor air temperature, indoor air temperature, outside wall surface temperature, and inside wall surface temperature were analyzed. Apart from the outdoor air temperature, the other three temperatures were all significantly affected by the design of green walls. Finally, energy savings in building cavities were determined. The indoor energy saving ratio of the LWS based on super soil reached 19.92%, followed by the LWS based on boxes at 15.37%, and green facades wall at 6.29%. The indoor cooling powers on this typical day showed that the cooling power of the LWS based on super soil was 8267.32 W, followed by the LWS based on boxes at 6381.57 W, and green facades wall at 2610.08 W. The results revealed the difference in cooling and energy-saving performance of different green walls in this typical hot summer area.

[1]  Diana Enescu,et al.  A review of thermal comfort models and indicators for indoor environments , 2017 .

[2]  A. V. D. Dobbelsteen,et al.  The impact of greening systems on building energy performance: A literature review , 2015 .

[3]  Juan A. Acero,et al.  Evaluating the performance of ENVI-met model in diurnal cycles for different meteorological conditions , 2016, Theoretical and Applied Climatology.

[4]  Rogelio Ortigosa,et al.  A new framework for large strain electromechanics based on convex multi-variable strain energies: Conservation laws, hyperbolicity and extension to electro-magneto-mechanics , 2016 .

[5]  Henrique Andrade,et al.  Comparison of measured and simulated Mean Radiant Temperature: case study in Lisbon (Portugal) , 2014 .

[6]  Helmut Mayer,et al.  Contribution of trees and grasslands to the mitigation of human heat stress in a residential district of Freiburg, Southwest Germany , 2016 .

[7]  R. Emmanuel,et al.  The impact of urban compactness, comfort strategies and energy consumption on tropical urban heat island intensity: A review , 2018, Sustainable Cities and Society.

[8]  Marc Ottelé,et al.  Greening the building envelope, facade greening and living wall systems , 2011 .

[9]  Ferdinando Salata,et al.  How high albedo and traditional buildings’ materials and vegetation affect the quality of urban microclimate. A case study , 2015 .

[10]  U. Berardi A cross-country comparison of the building energy consumptions and their trends , 2017 .

[11]  Sheikh Ahmad Zaki,et al.  A review on phase change material (PCM) for sustainable passive cooling in building envelopes , 2016 .

[12]  E. Ng,et al.  Thermal benefits of vertical greening in a high-density city: Case study of Hong Kong , 2017, Urban Forestry & Urban Greening.

[13]  Luis Fontan,et al.  A method for optimal sizing energy storage systems for microgrids , 2015 .

[14]  Kai Zhang,et al.  Air-conditioning system with underfloor air distribution integrated solar chimney in data center , 2017 .

[15]  Dominique Hes,et al.  Quantifying the thermal performance of green façades: A critical review , 2014 .

[16]  D. Kammen,et al.  City-integrated renewable energy for urban sustainability , 2016, Science.

[17]  Sasima Charoenkit,et al.  Living walls and their contribution to improved thermal comfort and carbon emission reduction: A review , 2016 .

[18]  Costas A. Varotsos,et al.  Atmospheric greenhouse effect in the context of global climate change , 1995 .

[19]  Dionysia Kolokotsa,et al.  Smart cooling systems for the urban environment. Using renewable technologies to face the urban climate change , 2017 .

[20]  Costas A. Varotsos,et al.  New spectral functions of the near-ground albedo derived from aircraft diffraction spectrometer observations , 2013 .

[21]  Diana S.N.M. Nasir,et al.  A CFD analysis of several design parameters of a road pavement solar collector (RPSC) for urban application , 2017 .

[22]  William J. Fisk,et al.  Energy and indoor air quality implications of alternative minimum ventilation rates in California offices , 2014 .

[23]  E. Hajidavalloo,et al.  Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. , 2010 .

[24]  A. K. Bregt,et al.  Urban heat indicator map for climate adaptation planning , 2015, Mitigation and Adaptation Strategies for Global Change.

[25]  Yacine Rezgui,et al.  Building energy metering and environmental monitoring – A state-of-the-art review and directions for future research , 2016 .

[26]  Marc Ottelé,et al.  Quantification of fine dust deposition on different plant species in a vertical greening system , 2017 .

[27]  Abbas Mohajerani,et al.  The urban heat island effect, its causes, and mitigation, with reference to the thermal properties of asphalt concrete. , 2017, Journal of environmental management.

[28]  Guangcheng Long,et al.  Progress in manufacture and properties of construction materials incorporating water treatment sludge: A review , 2019, Resources, Conservation and Recycling.

[29]  Jedediah B. Alvey,et al.  Simulating the effects of cool roof and PCM (phase change materials) based roof to mitigate UHI (urban heat island) in prominent US cities , 2016 .

[30]  C A Varotsos,et al.  The local and regional atmospheric oxidants at Athens (Greece) , 2013, Environmental Science and Pollution Research.

[31]  Feng Qian,et al.  Summertime thermal and energy performance of a double-skin green facade: A case study in Shanghai , 2018 .

[32]  Lihua Zhao,et al.  Evaluation of a microclimate model for predicting the thermal behavior of different ground surfaces , 2013 .

[33]  João Castro-Gomes,et al.  Green wall systems: A review of their characteristics , 2015, Renewable and Sustainable Energy Reviews.

[34]  Ali GhaffarianHoseini,et al.  A review on energy conscious designs of building façades in hot and humid climates: Lessons for (and from) Kuala Lumpur and Darwin , 2018 .

[35]  M. Bruse,et al.  Simulating surface–plant–air interactions inside urban environments with a three dimensional numerical model , 1998 .

[36]  Aakriti Grover,et al.  Analysis of Urban Heat Island (UHI) in Relation to Normalized Difference Vegetation Index (NDVI): A Comparative Study of Delhi and Mumbai , 2015 .

[37]  H. Takebayashi,et al.  Study to examine the potential for solar energy utilization based on the relationship between urban morphology and solar radiation gain on building rooftops and wall surfaces , 2015 .

[38]  Sabah A. Abdul-Wahab,et al.  Evaluation of the impact of ground-level concentrations of SO2, NOx, CO, and PM10 emitted from a steel melting plant on Muscat, Oman , 2018 .