Design of Wearable Headset with Steady State Visually Evoked Potential-Based Brain Computer Interface

Brain–computer interface (BCI) is a system that allows people to communicate directly with external machines via recognizing brain activities without manual operation. However, for most current BCI systems, conventional electroencephalography (EEG) machines and computers are usually required to acquire EEG signal and translate them into control commands, respectively. The sizes of the above machines are usually large, and this increases the limitation for daily applications. Moreover, conventional EEG electrodes also require conductive gels to improve the EEG signal quality. This causes discomfort and inconvenience of use, while the conductive gels may also encounter the problem of drying out during prolonged measurements. In order to improve the above issues, a wearable headset with steady-state visually evoked potential (SSVEP)-based BCI is proposed in this study. Active dry electrodes were designed and implemented to acquire a good EEG signal quality without conductive gels from the hairy site. The SSVEP BCI algorithm was also implemented into the designed field-programmable gate array (FPGA)-based BCI module to translate SSVEP signals into control commands in real time. Moreover, a commercial tablet was used as the visual stimulus device to provide graphic control icons. The whole system was designed as a wearable device to improve convenience of use in daily life, and it could acquire and translate EEG signal directly in the front-end headset. Finally, the performance of the proposed system was validated, and the results showed that it had excellent performance (information transfer rate = 36.08 bits/min).

[1]  Xiaorong Gao,et al.  A BCI-based environmental controller for the motion-disabled. , 2003, IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[2]  Ronald M. Aarts,et al.  A Survey of Stimulation Methods Used in SSVEP-Based BCIs , 2010, Comput. Intell. Neurosci..

[3]  Dennis J. McFarland,et al.  Brain–computer interfaces for communication and control , 2002, Clinical Neurophysiology.

[4]  J. Odom VISUAL EVOKED POTENTIALS STANDARD , 2004 .

[5]  M. A. Lopez-Gordo,et al.  Customized stimulation enhances performance of independent binary SSVEP-BCIs , 2011, Clinical Neurophysiology.

[6]  Gernot R. Müller-Putz,et al.  Control of an Electrical Prosthesis With an SSVEP-Based BCI , 2008, IEEE Transactions on Biomedical Engineering.

[7]  A Kostov,et al.  Parallel man-machine training in development of EEG-based cursor control. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[8]  D.J. McFarland,et al.  The wadsworth BCI research and development program: at home with BCI , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  Alan R. Jones,et al.  Fast Fourier Transform , 1970, SIGP.

[10]  Peng Yuan,et al.  A study of the existing problems of estimating the information transfer rate in online brain–computer interfaces , 2013, Journal of neural engineering.

[11]  Vaegan,et al.  Visual evoked potentials standard (2004) , 2004, Documenta Ophthalmologica.

[12]  Bor-Shyh Lin,et al.  A Wearable Channel Selection-Based Brain-Computer Interface for Motor Imagery Detection , 2016, Sensors.

[13]  G Calhoun,et al.  Brain-computer interfaces based on the steady-state visual-evoked response. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[14]  D. Regan Human brain electrophysiology: Evoked potentials and evoked magnetic fields in science and medicine , 1989 .

[15]  G. Pfurtscheller,et al.  EEG-based discrimination between imagination of right and left hand movement. , 1997, Electroencephalography and clinical neurophysiology.

[16]  E Donchin,et al.  The mental prosthesis: assessing the speed of a P300-based brain-computer interface. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[17]  A. Cichocki,et al.  Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives , 2010, Progress in Neurobiology.

[18]  Xiaorong Gao,et al.  Design and implementation of a brain-computer interface with high transfer rates , 2002, IEEE Transactions on Biomedical Engineering.

[19]  J. Tukey,et al.  An algorithm for the machine calculation of complex Fourier series , 1965 .

[20]  Feng Duan,et al.  Design of a Multimodal EEG-based Hybrid BCI System with Visual Servo Module , 2015, IEEE Transactions on Autonomous Mental Development.

[21]  S. Hillyard,et al.  Combining steady‐state visual evoked potentials and f MRI to localize brain activity during selective attention , 1997, Human brain mapping.

[22]  H. Flor,et al.  The thought translation device (TTD) for completely paralyzed patients. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[23]  Fabio Babiloni,et al.  The Dry Revolution: Evaluation of Three Different EEG Dry Electrode Types in Terms of Signal Spectral Features, Mental States Classification and Usability , 2019, Sensors.

[24]  L.J. Trejo,et al.  Brain-computer interfaces for 1-D and 2-D cursor control: designs using volitional control of the EEG spectrum or steady-state visual evoked potentials , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[25]  Miguel A. L. Nicolelis,et al.  Brain–machine interfaces: past, present and future , 2006, Trends in Neurosciences.

[26]  Lin Jzau Sheng,et al.  AN FPGA-BASED BCI SYSTEM WITH SSVEP AND PHASED CODING TECHNIQUES , 2018 .

[27]  G Pfurtscheller,et al.  EEG-based communication: improved accuracy by response verification. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[28]  Francesco Rundo,et al.  An Innovative Deep Learning Algorithm for Drowsiness Detection from EEG Signal , 2019, Comput..

[29]  S. Leonhardt,et al.  Characterization of textile electrodes and conductors using standardized measurement setups , 2010, Physiological measurement.

[30]  Dezhong Yao,et al.  Stimulator selection in SSVEP-based BCI. , 2008, Medical engineering & physics.

[31]  Jianhong Yang,et al.  Dry electrode for the measurement of biopotential signals , 2011, Science China Information Sciences.

[32]  Meng Wang,et al.  A Wearable SSVEP-Based BCI System for Quadcopter Control Using Head-Mounted Device , 2018, IEEE Access.