Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation System: Magnetic Remote Catheter Ablation

Background—Catheters are typically stiff and incorporate a pull-wire mechanism to allow tip deflection. While standing at the patient’s side, the operator manually navigates the catheter in the heart using fluoroscopic guidance. Methods and Results—A total of 42 patients (32 female; mean age, 55±15 years) underwent ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventricular nodal reentrant tachycardia (AVNRT) with the use of the magnetic navigation system Niobe (Stereotaxis, Inc). It consists of 2 computer-controlled permanent magnets located on opposite sides of the patient, which create a steerable external magnetic field (0.08 T). A small magnet embedded in the catheter tip causes the catheter to align and to be steered by the external magnetic field. A motor drive advances or retracts the catheter, enabling complete remote navigation. Radiofrequency current was applied with the use of a remote-controlled 4-mm, solid-tip, magnetic navigation–enabled catheter (55°C, maximum 40 W, 60 seconds) in all patients. The investigators, who were situated in the control room, performed the ablation using a mean of 7.2±4.7 radiofrequency current applications (mean fluoroscopy time, 8.9±6.2 minutes; procedure duration, 145±43 minutes). Slow pathway ablation was achieved in 15 patients, whereas slow pathway modulation was the end point in the remaining patients. There were no complications. Conclusions—The Niobe magnetic navigation system is a new platform technology allowing remote-controlled navigation of an ablation catheter. In conjunction with a motor drive unit, this system was used successfully to perform completely remote-controlled mapping and ablation in patients with AVNRT.

[1]  Heart catheterization in a neonate by interacting magnetic fields: a new and simple method of catheter guidance. , 1991, Catheterization and cardiovascular diagnosis.

[2]  R. Lazzara,et al.  Treatment of supraventricular tachycardia due to atrioventricular nodal reentry by radiofrequency catheter ablation of slow-pathway conduction. , 1992, The New England journal of medicine.

[3]  D. Krum,et al.  Selective Transcatheter Ablation of the Fast and Slow Pathways Using Radiofrequency Energy in Patients With Atrioventricular Nodal Reentrant Tachycardia , 1992, Circulation.

[4]  D. Commenges,et al.  Elimination of Atrioventricular Nodal Reentrant Tachycardia Using Discrete Slow Potentials to Guide Application of Radiofrequency Energy , 1992, Circulation.

[5]  G. Kay,et al.  Selective Radiofrequency Ablation of the Slow Pathway for the Treatment of Atrioventricular Nodal Reentrant Tachycardia: Evidence for Involvement of Perinodal Myocardium Within the Reentrant Circuit , 1992, Circulation.

[6]  M A Howard,et al.  Experimental study of the magnetic stereotaxis system for catheter manipulation within the brain. , 2000, Journal of neurosurgery.

[7]  A. Berkowitsch,et al.  [Clinical characteristics of patients with AV-nodal reentrant tachycardia (AVNRT): modification by high frequency catheter ablation. Study of 748 patients after high frequency catheter ablation]. , 2001, Medizinische Klinik.

[8]  B. Lindsay,et al.  Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation , 2002, Circulation.

[9]  Sabine Ernst,et al.  Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system Niobe. , 2004, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.