Why Are Total Knee Arthroplasties Failing Today?

The incidence of failure after knee replacement is low, yet it has been reported that more than 22,000 knee replacements are revised yearly. The purpose of the current study was to determine current mechanisms of failure of total knee arthroplasties. A retrospective review was done on all patients who had revision total knee arthroplasty during a 3-year period (September 1997–October 2000) at one institution. The preoperative evaluation in conjunction with radiographs, laboratory data, and intraoperative findings were used to determine causes of failure. Two hundred twelve surgeries were done on 203 patients (nine patients had bilateral surgeries). The reasons for failure listed in order of prevalence among the patients in this study include polyethylene wear, aseptic loosening, instability, infection, arthrofibrosis, malalignment or malposition, deficient extensor mechanism, avascular necrosis in the patella, periprosthetic fracture, and isolated patellar resurfacing. The cases reviewed included patients who had revision surgery within 9 days to 28 years (average, 3.7 years) after the previous surgery. More than half of the revisions in this group of patients were done less than 2 years after the index operation. Fifty percent of early revision total knee arthroplasties in this series were related to instability, malalignment or malposition, and failure of fixation.

[1]  Revision after total knee arthroplasty. , 1982, The Orthopedic clinics of North America.

[2]  G. Hunter,et al.  Failure in total knee arthroplasty: mechanisms, revisions, and results. , 1982, Clinical orthopaedics and related research.

[3]  Rand Ja,et al.  Revision after total knee arthroplasty. , 1982 .

[4]  G. McBride,et al.  Infected total knee arthroplasties. , 1985, Clinical orthopaedics and related research.

[5]  T. Fehring,et al.  Periprosthetic knee sepsis. The role of irrigation and debridement. , 1991, Clinical orthopaedics and related research.

[6]  T. Fehring,et al.  Knee instability after total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[7]  R E Booth,et al.  The patellar "clunk" syndrome after posterior stabilized total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[8]  R. Wixson,et al.  Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. , 1994, Clinical orthopaedics and related research.

[9]  R. Bourne,et al.  Catastrophic osteolysis in total knee replacement. A report of 17 cases. , 1995, Clinical orthopaedics and related research.

[10]  I. Pinder,et al.  Kinematic condylar total knee arthroplasty. 14-year survivorship analysis of 208 consecutive cases. , 1996, The Journal of bone and joint surgery. British volume.

[11]  Prophylactic use of antibiotics for procedures after total joint replacement. , 1996, The Journal of bone and joint surgery. American volume.

[12]  C. Robinson,et al.  Fracture of the metal tibial tray after Kinematic total knee replacement. A common cause of early aseptic failure. , 1996, The Journal of bone and joint surgery. British volume.

[13]  I. Pinder,et al.  Survivorship analysis of the Kinematic Stabilizer total knee replacement: a 10- to 14-year follow-up. , 1996, The Journal of bone and joint surgery. British volume.

[14]  T. Bauer,et al.  Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty. , 1996, Journal of biomedical materials research.

[15]  G. Engh,et al.  Tibial insert undersurface as a contributing source of polyethylene wear debris. , 1997, Clinical orthopaedics and related research.

[16]  G. Scuderi**,et al.  Survivorship of cemented total knee arthroplasty. , 1997, Clinical orthopaedics and related research.

[17]  José A. Rodriguez,et al.  The Press-Fit Condylar Modular Total Knee System. Four-to-Six-Year Results with a Posterior-Cruciate-Substituting Design* , 1997, The Journal of bone and joint surgery. American volume.

[18]  T. Fehring,et al.  Revision of Failed Cementless Total Knee Implants With Cement , 1998, Clinical orthopaedics and related research.

[19]  R. Dittus,et al.  Revision rates after knee replacement in the United States. , 1998, Medical care.

[20]  W. Chan,et al.  Isolated metal-backed patellar component revision following total knee arthroplasty. , 1998, Singapore medical journal.

[21]  R F Kyle,et al.  Infection after total knee arthroplasty. A retrospective study of the treatment of eighty-one infections. , 1999, The Journal of bone and joint surgery. American volume.

[22]  L. Nallamshetty,et al.  Early failure associated with the use of Hylamer-M spacers in three primary AMK total knee arthroplasties. , 2001, The Journal of arthroplasty.

[23]  D. Ip,et al.  Comparison of two total knee prostheses on the incidence of patella clunk syndrome , 2002, International Orthopaedics.

[24]  R. Barrack,et al.  Patellar Resurfacing in Total Knee Arthroplasty: A Prospective, Randomized, Double-Blind Study with Five to Seven Years of Follow-up , 2001, The Journal of bone and joint surgery. American volume.

[25]  D. Padgett,et al.  Instability after total knee arthroplasty with the Miller-Gallante II total knee: 5- to 7-year follow-up. , 2001, The Journal of arthroplasty.

[26]  S. Odum,et al.  Early Failures in Total Knee Arthroplasty , 2001, Clinical orthopaedics and related research.

[27]  P. Sharkey,et al.  Insall Award paper. Why are total knee arthroplasties failing today? , 2002, Clinical orthopaedics and related research.