Design of Two-Dimensional Ultrasonic Phased Array Transducers

Two-dimensional (2D) phased arrays have the potential to significantly change the way in which engineering components in safety critical industries are inspected. In addition to enabling a three-dimensional (3D) volume of a component to be inspected from a single location, they could also be used in a C-scan configuration. The latter would enable any point in a component to be interrogated over a range of solid angles, allowing more accurate defect characterization and sizing. This paper describes the simulation and evaluation of grid, cross and circular 2D phased array element configurations. The aim of the cross and circle configurations is to increase the effective aperture for a given number of elements. Due to the multitude of possible array element configurations a model, based on Huygens' principle, has been developed to allow analysis and comparison of candidate array designs. In addition to the element configuration, key issues such as element size, spacing, and frequency are discussed and quantitatively compared using the volume of the 3D point spread function (PSF) as a measurand. The results of this modeling indicate that, for a given number of elements, a circular array performs best and that the element spacing should be less than half a wavelength to avoid grating lobes. A prototype circular array has been built and initial results are presented. These show that a flat bottomed hole, half a wavelength in diameter, can be imaged. Furthermore, it is shown that the volume of the 3D reflection obtained experimentally from the end of the hole compares well with the volume of the 3D PSF predicted for the array at that point.

[1]  F. Foster,et al.  Fabrication and characterization of transducer elements in two-dimensional arrays for medical ultrasound imaging , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Michael D. Zoltowski,et al.  Eigenstructure techniques for 2-D angle estimation with uniform circular arrays , 1994, IEEE Trans. Signal Process..

[3]  S.W. Smith,et al.  Real-time rectilinear volumetric imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Shi-Chang Wooh,et al.  Optimum beam steering of linear phased arrays , 1999 .

[5]  Alistair McNab,et al.  The role of 3D graphics in NDT data processing , 2001 .

[6]  E. Wiener-avnear,et al.  Simulations of circular 2D phase-array ultrasonic imaging transducers. , 2002, Ultrasonics.

[7]  Steve Mahaut,et al.  Application of phased array techniques to coarse grain components inspection. , 2004, Ultrasonics.

[8]  Paul D. Wilcox,et al.  Post-processing of ultrasonic phased array data for optimal performance , 2005 .

[9]  Paul D. Wilcox,et al.  The post-processing of ultrasonic array data using the total focusing method , 2004 .

[10]  S. Norton Synthetic aperture imaging with arrays of arbitrary shape. II. The annular array , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.