Evaluation of CES and DFIG unit in AGC of realistic multisource deregulated power system

Summary This article discusses evaluation of dynamic contribution of wind turbine unit of doubly fed induction generators (DFIGs) type and capacitive energy storage (CES) in frequency regulation services in 2-area interconnected power system, having diverse thermal-hydro-gas (T-H-G) generating units in deregulated power environment. To obtain optimal dynamic responses of area's frequency oscillations following a small load perturbation, CES/DFIG units have been included in both control areas in coordination with thyristor controlled phase shifter (TCPS).The behavior of DFIGs to enhance dynamic performances of the proposed power system has been investigated by providing inertial support through modified inertial control scheme. The control scheme responds proportionally to frequency variations due to sudden load changes in the power system and uses wind turbine's kinetic energy to provide the inertial control support under several operational conditions. The gain parameters of the integral controller is obtained by using integral square error technique. The performance of the proposed system has been examined in different contract scenarios. Results show that the coordinated action of CES/DFIG units with TCPS unit provide optimal transient performance by arresting the initial dip in area frequencies as well as the power flow deviation in tie-line between the 2 areas. Further, analysis reveals that CES unit response is better and quicker than DFIG unit to damp the system oscillations.

[1]  Charles E. Fosha,et al.  Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems , 1970 .

[2]  P. Sangameswara Raju,et al.  Automatic generation control of TCPS based hydrothermal system under open market scenario: A fuzzy logic approach , 2009 .

[3]  A. Peer Fathima,et al.  Load frequency control in deregulated power system integrated with SMES–TCPS combination using ANFIS controller , 2016 .

[4]  Subhransu Sekhar Dash,et al.  Design of integral controller for Load Frequency Control of Static Synchronous Series Compensator and Capacitive Energy Source based multi area system consisting of diverse sources of generation employing Imperialistic Competition Algorithm , 2015 .

[5]  Rabindra Kumar Sahu,et al.  A novel hybrid gravitational search and pattern search algorithm for load frequency control of nonlinear power system , 2015, Appl. Soft Comput..

[6]  Nathan Cohn,et al.  Techniques for Improving the Control of Bulk Power Transfers on Interconnected Systems , 1971 .

[7]  Sakti Prasad Ghoshal,et al.  Optimized multi area AGC simulation in restructured power systems , 2010 .

[8]  Kalyan Chatterjee,et al.  Impact of energy storage system on load frequency control for diverse sources of interconnected power system in deregulated power environment , 2016 .

[9]  Ashwani Kumar,et al.  Participation of Doubly Fed Induction Generator Based Wind Turbine in Frequency Regulation with Frequency-linked Pricing , 2012 .

[10]  M. A. Pai,et al.  Simulation and Optimization in an AGC System after Deregulation , 2001, IEEE Power Engineering Review.

[11]  Sakti Prasad Ghoshal,et al.  Dynamic participation of doubly fed induction generator in automatic generation control , 2011 .

[12]  J. Nanda,et al.  Some new findings on automatic generation control of an interconnected hydrothermal system with conventional controllers , 2006, IEEE Transactions on Energy Conversion.

[13]  Ashwani Kumar,et al.  Load frequency control in deregulated power system with wind integrated system using fuzzy controller , 2013 .

[14]  Somanath Majhi,et al.  LFC of an interconnected power system with multi-source power generation in deregulated power environment , 2014 .

[15]  Prakash Kumar Hota,et al.  Differential evolution algorithm based automatic generation control for interconnected power systems with non-linearity , 2014 .

[16]  Y. K. Bhateshvar,et al.  Impact of wind power generating system integration on frequency stabilization in multi-area power system with fuzzy logic controller in deregulated environment , 2015 .

[17]  Somanath Majhi,et al.  Load frequency control of a realistic power system with multi-source power generation , 2012 .

[18]  Mehrdad Tarafdar Hagh,et al.  Effective oscillation damping of an interconnected multi-source power system with automatic generation control and TCSC , 2015 .

[19]  S. C. Tripathy,et al.  Dynamic performance of wind-diesel power system with capacitive energy storage , 1996 .

[20]  Prakash Kumar Hota,et al.  Automatic generation control of multi source power generation under deregulated environment , 2016 .

[21]  I. A. Chidambaram,et al.  Optimized load-frequency simulation in restructured power system with Redox Flow Batteries and Interline Power Flow Controller , 2013 .

[22]  Sakti Prasad Ghoshal,et al.  Coordinated control of TCPS and SMES for frequency regulation of interconnected restructured power systems with dynamic participation from DFIG based wind farm , 2012 .

[23]  Lalit Chandra Saikia,et al.  AGC of a multi-area thermal system under deregulated environment using a non-integer controller , 2013 .

[24]  J.A.P. Lopes,et al.  Participation of Doubly Fed Induction Wind Generators in System Frequency Regulation , 2007, IEEE Transactions on Power Systems.

[25]  Rabindra Kumar Sahu,et al.  DE optimized parallel 2-DOF PID controller for load frequency control of power system with governor dead-band nonlinearity , 2013 .

[26]  J. Nanda,et al.  Transactions on Power Apparatus and Systems , Vol . PAS-1 O 0 , No . 5 , May 1981 SAMPLED-DATA AUTOMATIC GENERATION CONTROL OF INTERCONNECTED REHEAT THERMAL SYSTEMS CONSIDERING GENERATION RATE CONSTRAINTS , 2006 .

[27]  S.C. Srivastava,et al.  A decentralized automatic generation control scheme for competitive electricity markets , 2006, IEEE Transactions on Power Systems.