The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation

Background The 6-min walk test (6MWT) is a convenient method for assessing functional capacity in patients with cardiopulmonary conditions. It is usually performed in the context of a hospital clinic and thus requires the involvement of hospital staff and facilities, with their associated costs. Objective This study aimed to develop a mobile phone–based system that allows patients to perform the 6MWT in the community. Methods We developed 2 algorithms to compute the distance walked during a 6MWT using sensors embedded in a mobile phone. One algorithm makes use of the global positioning system to track the location of the phone when outdoors and hence computes the distance travelled. The other algorithm is meant to be used indoors and exploits the inertial sensors built into the phone to detect U-turns when patients walk back and forth along a corridor of fixed length. We included these algorithms in a mobile phone app, integrated with wireless pulse oximeters and a back-end server. We performed Bland-Altman analysis of the difference between the distances estimated by the phone and by a reference trundle wheel on 49 indoor tests and 30 outdoor tests, with 11 different mobile phones (both Apple iOS and Google Android operating systems). We also assessed usability aspects related to the app in a discussion group with patients and clinicians using a technology acceptance model to guide discussion. Results The mean difference between the mobile phone-estimated distances and the reference values was −2.013 m (SD 7.84 m) for the indoor algorithm and −0.80 m (SD 18.56 m) for the outdoor algorithm. The absolute maximum difference was, in both cases, below the clinically significant threshold. A total of 2 pulmonary hypertension patients, 1 cardiologist, 2 physiologists, and 1 nurse took part in the discussion group, where issues arising from the use of the 6MWT in hospital were identified. The app was demonstrated to be usable, and the 2 patients were keen to use it in the long term. Conclusions The system described in this paper allows patients to perform the 6MWT at a place of their convenience. In addition, the use of pulse oximetry allows more information to be generated about the patient’s health status and, possibly, be more relevant to the real-life impact of their condition. Preliminary assessment has shown that the developed 6MWT app is highly accurate and well accepted by its users. Further tests are needed to assess its clinical value.

[1]  Ciro Casanova,et al.  Distance and oxygen desaturation during the 6-min walk test as predictors of long-term mortality in patients with COPD. , 2008, Chest.

[2]  Tao Liu,et al.  Gait Analysis Using Wearable Sensors , 2012, Sensors.

[3]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[4]  ATS statement: guidelines for the six-minute walk test. , 2002, American journal of respiratory and critical care medicine.

[5]  S. Staniszewska,et al.  Patient and Public Involvement in Patient-Reported Outcome Measures , 2012, The Patient - Patient-Centered Outcomes Research.

[6]  Bruce R. Schatz,et al.  GaitTrack: Health Monitoring of Body Motion from Spatio-Temporal Parameters of Simple Smart Phones , 2013, BCB.

[7]  Clare Hartigan,et al.  Mobility Outcomes Following Five Training Sessions with a Powered Exoskeleton. , 2015, Topics in spinal cord injury rehabilitation.

[8]  Karl Swedberg,et al.  Six minute walk test. , 2005, European heart journal.

[9]  Xitong Guo,et al.  UNDERSTANDING THE ACCEPTANCE OF MOBILE HEALTH SERVICES: A COMPARISON AND INTEGRATION OF ALTERNATIVE MODELS , 2013 .

[10]  A. Gray,et al.  Validity and reliability of GPS for measuring distance travelled in field-based team sports , 2010, Journal of sports sciences.

[11]  Scott L Delp,et al.  Quantified self and human movement: a review on the clinical impact of wearable sensing and feedback for gait analysis and intervention. , 2014, Gait & posture.

[12]  L. Cahalin,et al.  The six-minute walk test predicts peak oxygen uptake and survival in patients with advanced heart failure. , 1996, Chest.

[13]  D. Brooks,et al.  A qualitative systematic overview of the measurement properties of functional walk tests used in the cardiorespiratory domain. , 2001, Chest.

[14]  M. Schimpl,et al.  Development and Validation of a New Method to Measure Walking Speed in Free-Living Environments Using the Actibelt® Platform , 2011, PloS one.

[15]  J. Schulte,et al.  A remote sensor-based 6-minute functional walking ability test , 2012, 2012 IEEE Sensors.

[16]  M. Fujita,et al.  Clinical correlates and prognostic significance of six-minute walk test in patients with primary pulmonary hypertension. Comparison with cardiopulmonary exercise testing. , 2000, American journal of respiratory and critical care medicine.

[17]  Edward D Lemaire,et al.  Novel algorithm for a smartphone-based 6-minute walk test application: algorithm, application development, and evaluation , 2015, Journal of NeuroEngineering and Rehabilitation.

[18]  Stuart J. Cormack,et al.  The validity and reliability of GPS units for measuring distance in team sport specific running patterns. , 2010, International journal of sports physiology and performance.

[19]  O. Aalami,et al.  Clinical validation of smartphone-based activity tracking in peripheral artery disease patients , 2018, npj Digital Medicine.

[20]  S. Rosenkranz,et al.  Cologne consensus conference on pulmonary hypertension - Update 2018. , 2018, International journal of cardiology.

[21]  A. Levy,et al.  Sharpening the focus: differentiating between focus groups for patient engagement vs. qualitative research , 2018, Research Involvement and Engagement.

[22]  C. Worringham,et al.  Assessment of speed and position during human locomotion using nondifferential GPS. , 2008, Medicine and science in sports and exercise.

[23]  A. Holland,et al.  The six‐minute walk test: a useful metric for the cardiopulmonary patient , 2009, Internal medicine journal.

[24]  Edward D. Lemaire,et al.  A smartphone approach for the 2 and 6-minute walk test , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Kazuya Okamoto,et al.  Reliability and validity of gait analysis by android-based smartphone. , 2012, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[26]  Z. Jing,et al.  Macitentan and morbidity and mortality in pulmonary arterial hypertension. , 2013, The New England journal of medicine.

[27]  Rachel L. Goldfeder,et al.  Feasibility of Obtaining Measures of Lifestyle From a Smartphone App: The MyHeart Counts Cardiovascular Health Study , 2017, JAMA cardiology.

[28]  G. Kwakkel,et al.  Is outdoor use of the six-minute walk test with a global positioning system in stroke patients' own neighbourhoods reproducible and valid? , 2011, Journal of rehabilitation medicine.

[29]  Robert Grover Brown,et al.  Introduction to random signal analysis and Kalman filtering , 1983 .