Performance and Evaluation of Smartphone Based Wireless Blood Pressure Monitoring System Using Bluetooth

In medical practice, blood pressure is intensively studied parameter and often measured for diagnosis at primary healthcare level. In this paper, the state-of-the-art Bluetooth technology has been used for designing an innovative wireless blood pressure monitoring system to display the systolic and diastolic blood pressure values on Android-based smartphone. A pilot study was undertaken on 12 healthy subjects to validate the performance of developed prototype by comparing with OMRON HEM-7111 and mercury sphygmomanometer. Comparison shows an accuracy of 98.63% and 97.13% with OMRON HEM-7111 and 98.99% and 98% with mercury sphygmomanometer for systolic blood pressure and diastolic blood pressure, respectively. Bias value in Bland-Altman plots gives good level of agreement within 95% confidence limits. The developed prototype device mean and standard deviation of differences is less than 5 and 8 mmHg, respectively, and it fulfills the recommendation criteria as per the requirement of the Association for Advancement of Medical Instruments protocol.

[1]  Qun Wang,et al.  An improved algorithm for noninvasive blood pressure measurement , 2011, International Symposium on Bioelectronics and Bioinformations 2011.

[2]  Neelu Jain,et al.  Design and Validation of Android Based Wireless Integrated Device for Ubiquitous Health Monitoring , 2015, Wirel. Pers. Commun..

[3]  アーチボールド,ジー.ケント,et al.  Continuous non-invasive blood pressure monitoring system , 1994 .

[4]  Claire Rickard,et al.  Automated versus manual blood pressure measurement: a randomized crossover trial. , 2008, International journal of nursing practice.

[5]  M. Y. Mashor,et al.  A portable continuous blood pressure monitoring kit , 2011, 2011 IEEE Symposium on Business, Engineering and Industrial Applications (ISBEIA).

[6]  Feifei Yang,et al.  Implementation of cuff-less continuous blood pressure measurement system based on Android , 2012, 2012 IEEE International Conference on Information and Automation.

[7]  Zhang Jin-ling,et al.  Design of electronic blood pressure monitoring system based on mobile telemedicine system , 2013, 2013 ICME International Conference on Complex Medical Engineering.

[8]  Wang Yi,et al.  Noninvasive and Continuous Blood Pressure Monitoring Using Wearable Body Sensor Networks , 2015, IEEE Intelligent Systems.

[9]  Yuan-Hsiang Lin,et al.  A wireless blood pressure monitoring system for personal health management , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[10]  Qi Zhang,et al.  Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. , 2011, American journal of hypertension.

[11]  Revati Shriram,et al.  Continuous cuffless blood pressure monitoring based on PTT , 2010, 2010 International Conference on Bioinformatics and Biomedical Technology.