Accuracy of the Heidelberg Spectralis in the alignment between near-infrared image and tomographic scan in a model eye: a multicenter study.

PURPOSE To evaluate temporal changes and predictors of accuracy in the alignment between simultaneous near-infrared image and optical coherence tomography (OCT) scan on the Heidelberg Spectralis using a model eye. DESIGN Laboratory investigation. METHODS After calibrating the device, 6 sites performed weekly testing of the alignment for 12 weeks using a model eye. The maximum error was compared with multiple variables to evaluate predictors of inaccurate alignment. Variables included the number of weekly scanned patients, total number of OCT scans and B-scans performed, room temperature and its variation, and working time of the scanning laser. A 4-week extension study was subsequently performed to analyze short-term changes in the alignment. RESULTS The average maximum error in the alignment was 15 ± 6 μm; the greatest error was 35 μm. The error increased significantly at week 1 (P = .01), specifically after the second imaging study (P < .05); reached a maximum after the eighth patient (P < .001); and then varied randomly over time. Predictors for inaccurate alignment were temperature variation and scans per patient (P < .001). For each 1 unit of increase in temperature variation, the estimated increase in maximum error was 1.26 μm. For the average number of scans per patient, each increase of 1 unit increased the error by 0.34 μm. CONCLUSION Overall, the accuracy of the Heidelberg Spectralis was excellent. The greatest error happened in the first week after calibration, and specifically after the second imaging study. To improve the accuracy, room temperature should be kept stable and unnecessary scans should be avoided. The alignment of the device does not need to be checked on a regular basis in the clinical setting, but it should be checked after every other patient for more precise research purposes.

[1]  Jay Chhablani,et al.  Characterization of diabetic microaneurysms by simultaneous fluorescein angiography and spectral-domain optical coherence tomography. , 2012, American journal of ophthalmology.

[2]  S. Schwartz,et al.  Embryonic stem cell trials for macular degeneration: a preliminary report , 2012, The Lancet.

[3]  D. Palanker,et al.  LONG-TERM SAFETY, HIGH-RESOLUTION IMAGING, AND TISSUE TEMPERATURE MODELING OF SUBVISIBLE DIODE MICROPULSE PHOTOCOAGULATION FOR RETINOVASCULAR MACULAR EDEMA , 2012, Retina.

[4]  Austin Roorda,et al.  Outer retinal structure in patients with acute zonal occult outer retinopathy. , 2012, American journal of ophthalmology.

[5]  Daniel F Kiernan,et al.  Spectral-domain optical coherence tomography: a comparison of modern high-resolution retinal imaging systems. , 2010, American journal of ophthalmology.

[6]  Jay Chhablani,et al.  Characterization of microaneurysm closure after focal laser photocoagulation in diabetic macular edema. , 2013, American journal of ophthalmology.

[7]  W. Freeman,et al.  Combined depth imaging using optical coherence tomography as a novel imaging technique to visualize vitreoretinal choroidal structures. , 2013, Retina.

[8]  Jennifer I. Lim,et al.  A randomized, placebo-controlled, clinical trial of high-dose supplementation with vitamins C and E, beta carotene, and zinc for age-related macular degeneration and vision loss: AREDS report no. 8. , 2001, Archives of ophthalmology.

[9]  A. Fawzi,et al.  Spectral Domain Optical Coherence Tomography and Autofluorescence in a Case of Acute Posterior Multifocal Placoid Pigment Epitheliopathy Mimicking Vogt-Koyanagi-Harada Disease: Case Report and Review of Literature , 2011, Ocular immunology and inflammation.

[10]  G. Staurenghi,et al.  Aligning scan locations from consecutive spectral-domain optical coherence tomography examinations: a comparison among different strategies. , 2012, Investigative ophthalmology & visual science.

[11]  W. Freeman,et al.  Combined depth imaging technique on spectral-domain optical coherence tomography. , 2013, American journal of ophthalmology.

[12]  W. Inhoffen,et al.  Visualization and follow-up of acute macular neuroretinopathy with the Spectralis® HRA+OCT device , 2010, Graefe's Archive for Clinical and Experimental Ophthalmology.