Accurate and efficient image-intensifier distortion-correction algorithm and its application in volume tomographic angiography

An algorithm has been developed to correct the image distortion introduced by the image intensifier - CCD camera chain in our volume tomographic angiography imaging system. First the distorted image is partitioned into small quadrilateral regions, then each partition is mapped individually to the corrected image by its corresponding bilinear functions. The parameters of these bilinear functions can be acquired by a special calibration procedure and stored as a lookup table. The maximum errors before and after the distortion correction were measured to be 5.96 mm and 0.03 mm. The method is further applied to the 3D image reconstruction of a simulated vascular phantom and live animal studies.

[1]  Robert A. Kruger,et al.  Image-intensifier-based volume CT imager: angiographic application , 1990, Medical Imaging: Image Processing.

[2]  V. Jares The Effect of Electron Optics on the Properties of the X-Ray Image Intensifier , 1985 .

[3]  Robert A. Kruger,et al.  Image Intensifier-Based CT Volume Imager For Angiography , 1988, Medical Imaging.

[4]  Robert A. Kruger,et al.  Image Intensifier-Based CT Volume Imager For Angiography: System Evaluation , 1989, Medical Imaging.

[5]  R A Kruger,et al.  Image intensifier-based computed tomography volume scanner for angiography. , 1996, Academic radiology.

[6]  J. J. Gerbrands,et al.  Coronary Artery Dimensions from Cineangiograms-Methodology and Validation of a Computer-Assisted Analysis Procedure , 1984, IEEE Transactions on Medical Imaging.

[7]  Ruola Ning,et al.  Image-intensifier-based volume tomographic angiography imaging system: work in progress , 1993, Medical Imaging.

[8]  Ruola Ning,et al.  Image-intensifier-based volume tomographic angiography imaging system , 1997, Medical Imaging.

[9]  Beth A. Schueler,et al.  Correction of image intensifier distortion for three-dimensional x-ray angiography , 1995, Medical Imaging.

[10]  Ruola Ning,et al.  Image intensifier-based volume tomographic angiography imaging system: system evaluation , 1996, Medical Imaging.

[11]  Ruola Ning,et al.  Image-intensifier-based volume tomographic angiography imaging system: geometric distortion correction , 1994, Medical Imaging.

[12]  S. Rudin,et al.  Accurate characterization of image intensifier distortion. , 1991, Medical physics.

[13]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .