Known-component metal artifact reduction (KC-MAR) for cone-beam CT.

PURPOSE Intraoperative cone-beam CT (CBCT) is increasingly used for surgical navigation and validation of device placement. In spinal deformity correction, CBCT provides visualization of pedicle screws and fixation rods in relation to adjacent anatomy. This work reports and evaluates a method that uses prior information regarding such surgical instrumentation for improved metal artifact reduction (MAR). Methods. The known-component MAR (KC-MAR) approach achieves precise localization of instrumentation in projection images using rigid or deformable 3D-2D registration of component models, thereby overcoming residual errors associated with segmentation-based methods. Projection data containing metal components are processed via 2D inpainting of the detector signal, followed by 3D filtered back-projection (FBP). Phantom studies were performed to identify nominal algorithm parameters and quantitatively investigate performance over a range of component material composition and size. A cadaver study emulating screw and rod placement in spinal deformity correction was conducted to evaluate performance under realistic clinical imaging conditions. Results. KC-MAR demonstrated reduction in artifacts (standard deviation in voxel values) across a range of component types and dose levels, reducing the artifact to 5-10 HU. Accurate component delineation was demonstrated for rigid (screw) and deformable (rod) models with sub-mm registration errors, and a single-pixel dilation of the projected components was found to compensate for partial-volume effects. Artifacts associated with spine screws and rods were reduced by 40-80% in cadaver studies, and the resulting images demonstrated markedly improved visualization of instrumentation (e.g., screw threads) within cortical margins. Conclusions. The KC-MAR algorithm combines knowledge of surgical instrumentation with 3D image reconstruction in a manner that overcomes potential pitfalls of segmentation. The approach is compatible with FBP - thereby maintaining simplicity in a manner that is consistent with surgical workflow - or more sophisticated model-based reconstruction methods that could further improve image quality and/or help reduce radiation dose. .

[1]  Jerry L. Prince,et al.  Model-Based Tomographic Reconstruction of Objects Containing Known Components , 2012, IEEE Transactions on Medical Imaging.

[2]  Guillermo Sapiro,et al.  Simultaneous structure and texture image inpainting , 2003, IEEE Trans. Image Process..

[3]  Mohammad Hosntalab,et al.  Segmentation of teeth in CT volumetric dataset by panoramic projection and variational level set , 2008, International Journal of Computer Assisted Radiology and Surgery.

[4]  Hengyong Yu,et al.  Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography , 2017, IEEE Transactions on Medical Imaging.

[5]  D E Raeside,et al.  A pattern recognition method for the removal of streaking artifact in computed tomography. , 1981, Radiology.

[6]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[7]  Hilde Bosmans,et al.  Automated implant segmentation in cone-beam CT using edge detection and particle counting , 2014, International Journal of Computer Assisted Radiology and Surgery.

[8]  Patrick J. La Rivière,et al.  Penalized-likelihood sinogram restoration for computed tomography , 2006, IEEE Transactions on Medical Imaging.

[9]  Jeffrey A. Fessler,et al.  Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation , 2003 .

[10]  J. Hsieh,et al.  An iterative approach to the beam hardening correction in cone beam CT. , 2000, Medical physics.

[11]  A Uneri,et al.  Known-component 3D–2D registration for quality assurance of spine surgery pedicle screw placement , 2015, Physics in medicine and biology.

[12]  Lothar Spies,et al.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. , 2006, Medical physics.

[13]  Charles A. Bouman,et al.  Joint metal artifact reduction and segmentation of CT images using dictionary-based image prior and continuous-relaxed potts model , 2015, 2015 IEEE International Conference on Image Processing (ICIP).

[14]  A Uneri,et al.  Intraoperative evaluation of device placement in spine surgery using known-component 3D–2D image registration , 2017, Physics in medicine and biology.

[15]  Makoto Sakamoto,et al.  Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction , 2017, Neuroradiology.

[16]  Gaspar Delso,et al.  MR Image Based Approach for Metal Artifact Reduction in X-Ray CT , 2013, TheScientificWorldJournal.

[17]  T. P. Breckon,et al.  An evaluation of image denoising techniques applied to CT baggage screening imagery , 2013, 2013 IEEE International Conference on Industrial Technology (ICIT).

[18]  A. Jay Khanna,et al.  Polyenergetic known-component CT reconstruction with unknown material compositions and unknown x-ray spectra , 2017, Physics in medicine and biology.

[19]  Bruno De Man,et al.  Deep learning methods for CT image-domain metal artifact reduction , 2017, Optical Engineering + Applications.

[20]  David A Jaffray,et al.  Accurate technique for complete geometric calibration of cone-beam computed tomography systems. , 2005, Medical physics.

[21]  Ken D. Sauer,et al.  A Model-Based Image Reconstruction Algorithm With Simultaneous Beam Hardening Correction for X-Ray CT , 2015, IEEE Transactions on Computational Imaging.

[22]  Pei-Jan Paul Lin,et al.  A review of factors that affect artifact from metallic hardware on multi-row detector computed tomography. , 2010, Current problems in diagnostic radiology.

[23]  Antony J. Hodgson,et al.  A deep learning framework for segmentation and pose estimation of pedicle screw implants based on C-arm fluoroscopy , 2018, International Journal of Computer Assisted Radiology and Surgery.

[24]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[25]  Josh Star-Lack,et al.  Efficient scatter correction using asymmetric kernels , 2009, Medical Imaging.

[26]  W. Boehm Inserting New Knots into B-spline Curves , 1980 .

[27]  Rainer Raupach,et al.  Frequency split metal artifact reduction (FSMAR) in computed tomography. , 2012, Medical physics.

[28]  Hengyong Yu,et al.  A segmentation-based method for metal artifact reduction. , 2007, Academic radiology.

[29]  Jeffrey H Siewerdsen,et al.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study. , 2019, Medical physics.

[30]  Jikun Wei,et al.  X-ray CT high-density artefact suppression in the presence of bones , 2004, Physics in medicine and biology.

[31]  Rainer Raupach,et al.  Empirical scatter correction (esc): A new CT scatter correction method and its application to metal artifact reduction , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[32]  Willi A. Kalender,et al.  Algorithms for the reduction of CT artifacts caused by metallic implants , 1990, Medical Imaging.

[33]  David P. Dobkin,et al.  The quickhull algorithm for convex hulls , 1996, TOMS.

[34]  A Uneri,et al.  Image quality and dose characteristics for an O‐arm intraoperative imaging system with model‐based image reconstruction , 2018, Medical physics.

[35]  Tobias Funk,et al.  Computed Tomographic Metal Artifact Reduction for the Detection and Quantitation of Small Features Near Large Metallic Implants: A Comparison of Published Methods , 2008, Journal of computer assisted tomography.

[36]  Nikolaus Hansen,et al.  Completely Derandomized Self-Adaptation in Evolution Strategies , 2001, Evolutionary Computation.

[37]  R. Brooks,et al.  Beam hardening in X-ray reconstructive tomography , 1976 .

[38]  Mehran Yazdi,et al.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. , 2005, International journal of radiation oncology, biology, physics.

[39]  Christian Steiding,et al.  Metal Artifact Reduction in X-ray Computed Tomography Using Computer-Aided Design Data of Implants as Prior Information , 2017, Investigative radiology.

[40]  Lei Dong,et al.  Reducing metal artifacts in cone-beam CT images by preprocessing projection data. , 2007, International journal of radiation oncology, biology, physics.

[41]  R. Alvarez,et al.  An inaccuracy in computed tomography: the energy dependence of CT values. , 1977, Radiology.

[42]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[43]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[44]  David Faul,et al.  Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completion , 2009, IEEE Transactions on Medical Imaging.

[45]  Gerhard Kleinszig,et al.  Deformable 3D-2D Registration of Known Components for Image Guidance in Spine Surgery , 2016, MICCAI.

[46]  Seemeen Karimi,et al.  Segmentation of artifacts and anatomy in CT metal artifact reduction. , 2012, Medical physics.

[47]  Jeffrey H. Siewerdsen,et al.  High-contrast object localization and removal in cone-beam CT , 2005, SPIE Medical Imaging.

[48]  Marc Kachelrieß,et al.  Empirical beam hardening correction (EBHC) for CT. , 2010, Medical physics.

[49]  Krishna Subramanyan,et al.  A radial adaptive filter for metal artifact reduction , 2005, SPIE Medical Imaging.

[50]  Ulla Ruotsalainen,et al.  Combining dual-tree complex wavelets and multiresolution in iterative CT reconstruction with application to metal artifact reduction , 2019, BioMedical Engineering OnLine.

[51]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .