SPRITE MRI with prepared magnetization and centric k-space sampling

A technique for imaging materials with short transverse relaxation times and prepared longitudinal magnetization is proposed. The technique is single-point ramped imaging with T1-enhancement (SPRITE) MRI with centric k-space sampling. The effects of transient state behavior on image resolution and signal/noise are estimated. Centric sampling in the basic SPRITE sequence gives increased signal-to-noise and permits a quantitative determination of the MR parameters associated with longitudinal spin preparation. Spin-lock and inversion recovery preparation experiments are presented. Copyright 1999 Academic Press.

[1]  R. Kimmich NMR: Tomography, Diffusometry, Relaxometry , 2001 .

[2]  R R Price,et al.  Diffusion imaging with the MP‐rage sequence , 1994, Journal of magnetic resonance imaging : JMRI.

[3]  S. Braun,et al.  100 and more basic NMR experiments , 1996 .

[4]  J. Mugler,et al.  Shaping the Signal Response during the Approach to Steady State in Three‐Dimensional Magnetization‐Prepared Rapid Gradient‐Echo Imaging Using Variable Flip Angles , 1992, Magnetic resonance in medicine.

[5]  M K Stehling Improved signal in "snapshot" FLASH by variable flip angles. , 1992, Magnetic resonance imaging.

[6]  J. Hennig Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes , 1991 .

[7]  D Chien,et al.  Signal strength in subsecond FLASH magnetic resonance imaging: the dynamic approach to steady state. , 1990, Medical physics.

[8]  A. Haase,et al.  Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging , 1990, Magnetic resonance in medicine.

[9]  S J Riederer,et al.  Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath‐hold three‐dimensional gradient echo imaging , 1997, Magnetic resonance in medicine.

[10]  D. Feinberg,et al.  Single‐shot GRASE imaging with short effective TEs , 1996, Journal of magnetic resonance imaging : JMRI.

[11]  D Chien,et al.  Strategies to improve contrast in turboFLASH imaging: Reordered phase encoding and K‐space segmentation , 1991, Journal of magnetic resonance imaging : JMRI.

[12]  T W Bremner,et al.  Relaxation time mapping of short T*2 nuclei with single-point imaging (SPI) methods. , 1998, Journal of magnetic resonance.

[13]  Jens Frahm,et al.  Transverse coherence in rapid FLASH NMR imaging , 1987 .

[14]  B. Blümich,et al.  Magnetization filters: applications to NMR imaging of elastomers. , 1992, Magnetic resonance imaging.

[15]  E M Haacke,et al.  The effects of finite sampling in spin‐echo or field‐echo magnetic resonance imaging , 1987, Magnetic resonance in medicine.

[16]  J. Mugler,et al.  Improved T1‐weighted two‐dimensional MP‐GRE imaging of the liver with variable flip angles for shaping the signal evolution , 1994, Journal of magnetic resonance imaging : JMRI.

[17]  S. Emid,et al.  High resolution NMR imaging in solids , 1985 .

[18]  Weili Lin,et al.  A fast, iterative, partial-fourier technique capable of local phase recovery , 1991 .

[19]  Elimination of susceptibility distortions and reduction of diffusion attenuation in NMR microscopy by line‐narrowed 2DFT , 1993, Magnetic resonance in medicine.

[20]  D. Feinberg,et al.  Halving MR imaging time by conjugation: demonstration at 3.5 kG. , 1986, Radiology.

[21]  S J Riederer,et al.  Improved centric phase encoding orders for three‐dimensional magnetization‐prepared mr angiography , 1996, Magnetic resonance in medicine.

[22]  S J Riederer,et al.  The importance of phase‐encoding order in ultra‐short TR snapshot MR imaging , 1990, Magnetic resonance in medicine.

[23]  S. T. Nichols,et al.  Quantitative evaluation of several partial fourier reconstruction algorithms used in mri , 1993, Magnetic resonance in medicine.