Relation between heart rate and pulse transit time during paced respiration

Pulse transit time (PTT) is a simple, non-invasive measurement, defined as the time taken from a reference time for the pulse pressure wave to travel to the periphery. PTT is influenced by heart rate, blood pressure changes and the compliance of the arteries, but few quantitative data are available describing the factors which influence PTT. The aim of this study was to investigate the relationship between the cardiac beat-to-beat interval (RR) and PTT, using paced respiration to generate changes in both variables. We analysed PTT and RR interval from 15 normal healthy subjects during paced breathing, and the cross-correlation function between PTT and RR was used to quantify their relationship. Over the 15 subjects, the maximum change in PTT ranged from 7 to 23 ms with a mean ± standard deviation of 14±5 ms, and that in RR interval from 86 to 443 ms (241±102 ms). Examining changes over time, the best correlation (r = + 0.69, p<0.01) was obtained when PTT was advanced relative to RR, with a change in RR followed by a corresponding change in PTT 3.17±0.76 beats later. We conclude that there is a strong relationship between PTT changes and RR interval changes, but these changes are not in phase.

[1]  B. Pannier,et al.  Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies. , 1995, Hypertension.

[2]  J Strackee,et al.  Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model. , 1987, The American journal of physiology.

[3]  Emmanuel Ifeachor,et al.  Digital Signal Processing: A Practical Approach , 1993 .

[4]  J. Fleg,et al.  Effects of Age and Aerobic Capacit on Arterial Stiffness in Healthy Adults , 1993, Circulation.

[5]  A. Murray,et al.  Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[6]  A. Steptoe,et al.  Pulse wave velocity as a measure of blood pressure change. , 1976, Psychophysiology.

[7]  K. Takazawa,et al.  Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. , 2000, American journal of hypertension.

[8]  J. Stradling,et al.  Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. , 1995, The European respiratory journal.

[9]  Alan Murray,et al.  Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes , 2000 .

[10]  A Murray,et al.  Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes , 2000, Physiological measurement.

[11]  A Murray,et al.  Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveforms. , 1993, Physiological measurement.

[12]  V. Somers,et al.  Heart Rate Variability: , 2003, Journal of cardiovascular electrophysiology.