Suppression of Air Refractive Index Variations in High-Resolution Interferometry

The influence of the refractive index of air has proven to be a major problem on the road to improvement of the uncertainty in interferometric displacement measurements. We propose an approach with two counter-measuring interferometers acting as a combination of tracking refractometer and a displacement interferometer referencing the wavelength of the laser source to a mechanical standard made of a material with ultra-low thermal expansion. This technique combines length measurement within a specified range with measurement of the refractive index fluctuations in one axis. Errors caused by different position of the interferometer laser beam and air sensors are thus eliminated. The method has been experimentally tested in comparison with the indirect measurement of the refractive index of air in a thermal controlled environment. Over a 1 K temperature range an agreement on the level of 5 × 10−8 has been achieved.

[1]  Saeed Olyaee,et al.  Jones matrix analysis of frequency mixing error in three-longitudinal-mode laser heterodyne interferometer , 2009 .

[2]  K. P. Birch,et al.  LETTER TO THE EDITOR: Correction to the Updated Edln Equation for the Refractive Index of Air , 1994 .

[3]  Ondřej Číp,et al.  Problems regarding linearity of data of a laser interferometer with a single-frequency laser , 1999 .

[4]  Gaetano Scamarcio,et al.  Laser-Self-Mixing Interferometry for Mechatronics Applications , 2009, Sensors.

[5]  P. Ciddor,et al.  Refractive index of air: 3. The roles of CO2, H2O, and refractivity virials. , 2002, Applied optics.

[6]  Ondrej Cip,et al.  A scale-linearization method for precise laser interferometry , 2000 .

[7]  Josef Lazar,et al.  Absolute Distance Measurements with Tunable Semiconductor Laser , 2005 .

[8]  J. L. Hall,et al.  Real-time precision refractometry: new approaches. , 1997, Applied optics.

[9]  G. B. nsch,et al.  Measurement of the refractive index of air and comparison with modified Edl?n's formulae , 1998 .

[10]  Andrew Yacoot,et al.  The use of x-ray interferometry to investigate the linearity of the NPL Differential Plane Mirror Optical Interferometer , 2000 .

[11]  L J Wang,et al.  Precision measurement of the refractive index of air with frequency combs. , 2005, Optics letters.

[12]  S. Topcu,et al.  Heterodyne refractometer and air wavelength reference at 633 nm , 2003 .

[13]  Antti Lassila,et al.  Acoustic method for the determination of the effective temperature and refractive index of air , 2003, SPIE Optics + Photonics.

[14]  T J Quinn,et al.  Practical realization of the definition of the metre, including recommended radiations of other optical frequency standards (2001) , 2003 .

[15]  Bryan Kok Ann Ngoi,et al.  Self-Compensated Heterodyne Laser Interferometer , 2000 .

[16]  Alexander Walkov,et al.  High-accuracy determination of water vapor refractivity by length interferometry. , 2006, Optics letters.

[17]  O. Číp,et al.  Precise length etalon controlled by stabilized frequency comb , 2008 .

[18]  J. Nunn,et al.  Verification of the sub-nanometric capability of an NPL differential plane mirror interferometer with a capacitance probe , 1998 .

[19]  P. Ciddor Refractive index of air: new equations for the visible and near infrared. , 1996, Applied optics.

[20]  F. Petru,et al.  Single-frequency HeNe laser with a central maximum of output power , 1993 .

[21]  J Lazar,et al.  The design of a compact and tunable extended-cavity semiconductor laser , 2004 .

[22]  K. P. Birch,et al.  An Updated Edln Equation for the Refractive Index of Air , 1993 .

[23]  A. Picard,et al.  Three methods of determining the density of moist air during mass comparisons , 2002 .

[24]  Masato Aketagawa,et al.  Measurement of air-refractive-index fluctuation from frequency change using a phase modulation homodyne interferometer and an external cavity laser diode , 2008, International Symposium on Laser Metrology.

[25]  Ouali Acef,et al.  Absolute frequency measurement of an I2 stabilized Nd:YAG optical frequency standard , 2002 .

[26]  P. Juncar,et al.  A heterodyne refractometer for air index of refraction and air density measurements , 2002 .

[27]  Zehuang Lu,et al.  Application of frequency combs in the measurement of the refractive index of air , 2006 .

[28]  B. Edĺen The Refractive Index of Air , 1966 .

[29]  Y P Kathuria Accurate measurement of refractive index of gases using a laser interferometer , 1991 .

[30]  K. Meiners-Hagen,et al.  Refractive index determination in length measurement by two-colour interferometry , 2008 .

[31]  Zdenek Buchta,et al.  Optical pumping of Rb by Ti:Sa laser and high-power laser diode , 2006 .

[32]  Masato Aketagawa,et al.  Measurement of air-refractive-index fluctuation from laser frequency shift with uncertainty of order 10−9 , 2009 .

[33]  Gwo-Sheng Peng,et al.  Correction of nonlinearity in one-frequency optical interferometry , 1996 .

[34]  Fernando Seco Granja,et al.  A Real-Time Tool Positioning Sensor for Machine-Tools , 2009, Sensors.

[35]  Mikko Merimaa,et al.  Spectroscopic Measurement of Air Temperature , 2010 .

[36]  Masato Aketagawa,et al.  Active suppression of air refractive index fluctuation using a Fabry-Perot cavity and a piezoelectric volume actuator. , 2011, Applied optics.

[37]  Patrick Juncar,et al.  A new simple compact refractometer applied to measurements of air density fluctuations , 1999 .

[38]  A. Moene,et al.  Effects of water vapour on the structure parameter of the refractive index for near-infrared radiation , 2003 .