different systems Transit time flow measurement: experimental validation and comparison of three

[1]  T. Carrel,et al.  Failed coronary artery bypass anastomosis detected by intraoperative coronary flow measurement. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  L. Gray,et al.  Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG. , 1998, The Annals of thoracic surgery.

[3]  O. Hess,et al.  Transit-time flow measurement for detection of early graft failure during myocardial revascularization. , 1998, The Annals of thoracic surgery.

[4]  E. M. Pedersen,et al.  Validation of a new transit time ultrasound flowmeter in man. , 1996, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[5]  B. Walpoth,et al.  Intraoperative internal mammary artery transit-time flow measurements: comparative evaluation of two surgical pedicle preparation techniques. , 1996, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[6]  J. Jamart,et al.  Intraoperative assessment of coronary artery bypass grafts using a pulsed Doppler flowmeter. , 1994, The Annals of thoracic surgery.

[7]  K Matre,et al.  Comparison of transit-time and Doppler ultrasound methods for measurement of flow in aortocoronary bypass grafts during cardiac surgery. , 1994, The Thoracic and cardiovascular surgeon.

[8]  Y. Louagie,et al.  Intraoperative electromagnetic flowmeter measurements in coronary artery bypass grafts. , 1994, The Annals of thoracic surgery.

[9]  D Bergqvist,et al.  Prediction of early graft occlusion in femoropopliteal and femorodistal reconstruction by measurement of volume flow with a transit time flowmeter and calculation of peripheral resistance. , 1993, European journal of vascular surgery.

[10]  E. Mattsson,et al.  Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study. , 1993, Clinical physiology.

[11]  D. Wong,et al.  Comparison of Changes in Transit Time Ultrasound, Esophageal Doppler, and Thermodilution Cardiac Output After Changes in Preload, Afterload, and Contractility in Pigs , 1991, Anesthesia and analgesia.

[12]  F. Veith,et al.  Outflow resistance measurement during infrainguinal arterial reconstructions: a reliable predictor of limb salvage. , 1987, American journal of surgery.

[13]  F. Veith,et al.  Intraoperative outflow resistance as a predictor of late patency of femoropopliteal and infrapopliteal arterial bypasses. , 1987, Journal of vascular surgery.

[14]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[15]  F. Veith,et al.  Components of outflow resistance and their correlation with graft patency in lower extremity arterial reconstructions. , 1984, Journal of vascular surgery.

[16]  K G Plass,et al.  A new ultrasonic flowmeter for intravascular application. , 1964, IEEE transactions on bio-medical engineering.