A 9.2-Gram Fully-Flexible Wireless Dry-Electrode Headband for Non-Contact Artifact-Resilient EEG Monitoring and Programmable Diagnostics

An 8-channel wearable wireless device for surface EEG monitoring is presented. The entire multi-channel recording, quantization, and motion artifact removal is implemented on a 4-layer polyimide flexible substrate. The recording electrodes and active shielding are also integrated on the same substrate, yielding the smallest form factor compared to the state of the art. Thanks to the dry non-contact electrodes, the system is quickly mountable with minimal assistance required, making it an ideal frontal and temporal-lobe EEG monitoring device in emergency departments. The flexible main board is connected to a rechargeable battery on one end and to a 13×17mm2 rigid board on the other end. The mini rigid board hosts a low-power programmable FPGA and a BLE 5.0 transceiver, which add diagnostic capability and wireless operation features to the device, respectively. The device performance in terms of voltage gain (260 V/V), bandwidth (DC-700 Hz), input-referred noise, motion artifact removal, and wireless communication throughput (up to 1Mbps) is experimentally validated and the overall power consumption is measured to be 27mW. The entire wearable solution with the battery weight 9.2 grams.

[1]  Karim Abdelhalim,et al.  Battery-less Tri-band-Radio Neuro-monitor and Responsive Neurostimulator for Diagnostics and Treatment of Neurological Disorders , 2016, IEEE Journal of Solid-State Circuits.

[2]  Roman Genov,et al.  Electronic Sleep Stage Classifiers: A Survey and VLSI Design Methodology , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[3]  W. Brady,et al.  Altered mental status: evaluation and etiology in the ED. , 2002, The American journal of emergency medicine.

[4]  Karim Abdelhalim,et al.  Closed-Loop Neurostimulators: A Survey and A Seizure-Predicting Design Example for Intractable Epilepsy Treatment , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Roman Genov,et al.  27.3 All-wireless 64-channel 0.013mm2/ch closed-loop neurostimulator with rail-to-rail DC offset removal , 2017, 2017 IEEE International Solid-State Circuits Conference (ISSCC).

[6]  Refet Firat Yazicioglu,et al.  A Wearable 8-Channel Active-Electrode EEG/ETI Acquisition System for Body Area Networks , 2014, IEEE Journal of Solid-State Circuits.

[7]  M. T. Salam,et al.  Rapid brief feedback intracerebral stimulation based on real‐time desynchronization detection preceding seizures stops the generation of convulsive paroxysms , 2015, Epilepsia.

[8]  T. Erkinjuntti,et al.  Dementia among medical inpatients. Evaluation of 2000 consecutive admissions. , 1986, Archives of internal medicine.

[9]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[10]  Roman Genov,et al.  Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator , 2017, IEEE Journal of Solid-State Circuits.

[11]  P. Vespa Continuous EEG Monitoring for the Detection of Seizures in Traumatic Brain Injury, Infarction, and Intracerebral Hemorrhage: “To Detect and Protect” , 2005, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[12]  G. Gottlieb,et al.  Differential Diagnosis of Dementia, Delirium and Depression , 1994, Drugs & aging.