Sources of variability in the quantification of tissue optical properties by multidiameter single-fiber reflectance and fluorescence spectroscopy

Abstract. Recently, a multidiameter single-fiber reflectance and fluorescence spectroscopy device has been developed that enabled us to extract the autofluorescence of tissue that is corrected for the optical properties. Such a system has been incorporated in the population-based Rotterdam Study to investigate the autofluorescence of the skin. Since the device will be used by different operators over many years, it is essential that the results are comparable between users. It is, however, unclear how different methods of handling the probe might influence the outcome. Variability of blood oxygen saturation, blood volume fraction and vessel diameter, average gamma, reduced scattering coefficient at 800 nm, and integrated intrinsic fluorescence measured in three volunteers were assessed within and between eight untrained users. A variability of less than one standard deviation from the group mean was defined as an acceptable limit. Three mature volunteers were also included to assess the intrauser variability of mature skin. The variation in the measured parameters suggests that variation is dominated by tissue heterogeneity. Most users measured within one standard deviation of the group mean. Notably, corrected intrinsic fluorescence showed low intra- and interuser variability. These results strongly suggest that variability is mostly caused by tissue heterogeneity and is not user induced.

[1]  Vadim Backman,et al.  Nonscalar elastic light scattering from continuous random media in the Born approximation. , 2009, Optics letters.

[2]  F. Powell Flushing and Blushing , 2008 .

[3]  B. Vásárhelyi,et al.  Verification of skin autofluorescence values by mass spectrometry in adolescents with type 1 diabetes: brief report. , 2013, Diabetes technology & therapeutics.

[4]  U. A. Gamm,et al.  Quantification of the reduced scattering coefficient and phase-function-dependent parameter γ of turbid media using multidiameter single fiber reflectance spectroscopy: experimental validation. , 2012, Optics letters.

[5]  A. Amelink,et al.  Monte Carlo analysis of single fiber reflectance spectroscopy: photon path length and sampling depth , 2009, Physics in medicine and biology.

[6]  Arjen Amelink,et al.  In vivo measurement of the local optical properties of tissue by use of differential path-length spectroscopy. , 2004, Optics letters.

[7]  Arjen Amelink,et al.  Extraction of intrinsic fluorescence from single fiber fluorescence measurements on a turbid medium. , 2012, Optics letters.

[8]  Arjen Amelink,et al.  Method for rapid multidiameter single-fiber reflectance and fluorescence spectroscopy through a fiber bundle , 2013, Journal of biomedical optics.

[9]  A. Amelink,et al.  Measurement of the reduced scattering coefficient of turbid media using single fiber reflectance spectroscopy: fiber diameter and phase function dependence , 2011, Biomedical optics express.

[10]  Arjen Amelink,et al.  Method to quantitatively estimate wavelength-dependent scattering properties from multidiameter single fiber reflectance spectra measured in a turbid medium. , 2011, Optics letters.

[11]  G. I. Taylor,et al.  The vascular territories (angiosomes) of the body: experimental study and clinical applications. , 1987, British journal of plastic surgery.

[12]  A. Amelink,et al.  Measurement of tissue scattering properties using multi-diameter single fiber reflectance spectroscopy: in silico sensitivity analysis , 2011, Biomedical optics express.