Comparison between microprocessor-controlled ankle/foot and conventional prosthetic feet during stair negotiation in people with unilateral transtibial amputation.

Contrary to stance-phase dorsiflexion of conventional prosthetic feet, the microprocessor-controlled Proprio foot permits swing-phase dorsiflexion on stairs. The purpose of this study was to compare Symmetry in External Work (SEW) between a microprocessor-controlled foot and conventional prosthetic feet in two groups with unilateral transtibial amputation (Medicare Functional Classification Levels K-Level-2 and K-Level-3) during stair ascent and descent. Ten subjects were evaluated while wearing three conventional prosthetic feet- solid ankle cushion heel (SACH), stationary attachment flexible endoskeleton (SAFE), and Talux-and the Proprio foot using a study socket and were given a 10- to 14-day accommodation period with each foot. Ground reaction forces were collected using F-scan sensors during stair ascent and descent. The SEW between the intact and amputated limbs was calculated for each foot. During stair ascent, the Proprio foot resulted in a higher interlimb symmetry than conventional prosthetic feet, with significant differences between the Pro prio and SACH/SAFE feet. The swing-phase dorsiflexion appeared to promote greater interlimb symmetry because it facilitated forward motion of the body, resulting in a heel-to-toe center of pressure trajectory. During stair descent, all feet had low symmetry without significant differences between feet. The movement strategy used when descending stairs, which is to roll over the edge of a step, had a greater influence on symmetry than the dorsiflexion features of prosthetic feet.

[1]  David H. Nielsen,et al.  Kinetic Patterns During Stair Ascent in Patients with Transtibial Amputations Using Three Different Prostheses , 1999 .

[2]  J Perry,et al.  Below-knee amputee gait with dynamic elastic response prosthetic feet: a pilot study. , 1990, Journal of rehabilitation research and development.

[3]  Robert Gailey,et al.  Symmetry in External Work (SEW): A Novel Method of Quantifying Gait Differences Between Prosthetic Feet , 2009, Prosthetics and orthotics international.

[4]  M. Nash,et al.  The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee's abi , 2002 .

[5]  M. Koch,et al.  Plantardruckmessung im Konfektionsschuh mit der TEKSCAN Sensorfolie. In-shoe Plantar Measurement with TEKSCAN Sensor System , 1993 .

[6]  R. Gailey,et al.  Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use. , 2008, Journal of rehabilitation research and development.

[7]  Alex Stacoff,et al.  Ground reaction forces on stairs: effects of stair inclination and age. , 2005, Gait & posture.

[8]  D. Winter,et al.  An integrated biomechanical analysis of normal stair ascent and descent. , 1988, Journal of biomechanics.

[9]  M Koch [Measuring plantar pressure in conventional shoes with the TEKSCAN sensory system]. , 1993, Biomedizinische Technik. Biomedical engineering.

[10]  M J Mueller,et al.  Generalizability of in-shoe peak pressure measures using the F-scan system. , 1996, Clinical biomechanics.

[11]  T. Andriacchi,et al.  A study of lower-limb mechanics during stair-climbing. , 1980, The Journal of bone and joint surgery. American volume.

[12]  Pradeep Suri,et al.  Osteoarthritis in the Disabled Population: A Mechanical Perspective , 2012, PM & R : the journal of injury, function, and rehabilitation.

[13]  R. Riener,et al.  Stair ascent and descent at different inclinations. , 2002, Gait & posture.

[14]  M. Nash,et al.  The amputee mobility predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate. , 2002, Archives of physical medicine and rehabilitation.

[15]  S. Wolf,et al.  Kinematics and kinetics with an adaptive ankle foot system during stair ambulation of transtibial amputees. , 2009, Gait & posture.

[16]  Thomas Schmalz,et al.  Biomechanical analysis of stair ambulation in lower limb amputees. , 2007, Gait & posture.

[17]  J Perry,et al.  Below-knee amputee gait in stair ambulation. A comparison of stride characteristics using five different prosthetic feet. , 1994, Clinical orthopaedics and related research.