A PDMS-Based Conical-Well Microelectrode Array for Surface Stimulation and Recording of Neural Tissues

A method for fabricating polydimethylsiloxane (PDMS) based microelectrode arrays (MEAs) featuring novel conical-well microelectrodes is described. The fabrication technique is reliable and efficient, and facilitates controllability over both the depth and the slope of the conical wells. Because of the high-PDMS elasticity (as compared to other MEA substrate materials), this type of compliant MEA is promising for acute and chronic implantation in applications that benefit from conformable device contact with biological tissue surfaces and from minimal tissue damage. The primary advantage of the conical-well microelectrodes-when compared to planar electrodes-is that they provide an improved contact on tissue surface, which potentially provides isolation of the electrode microenvironment for better electrical interfacing. The raised wells increase the uniformity of current density distributions at both the electrode and tissue surfaces, and they also protect the electrode material from mechanical damage (e.g., from rubbing against the tissue). Using this technique, electrodes have been fabricated with diameters as small as 10 m and arrays have been fabricated with center-to-center electrode spacings of 60 m . Experimental results are presented, describing electrode-profile characterization, electrode-impedance measurement, and MEA-performance evaluation on fiber bundle recruitment in spinal cord white matter.

[1]  David J. Anderson,et al.  Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes , 2001 .

[2]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[3]  G J Suaning,et al.  Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil , 2005, Journal of neural engineering.

[4]  J. Pine Recording action potentials from cultured neurons with extracellular microcircuit electrodes , 1980, Journal of Neuroscience Methods.

[5]  D.B. McCreery,et al.  Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation , 1990, IEEE Transactions on Biomedical Engineering.

[6]  Chong H. Ahn,et al.  A tapered hollow metallic microneedle array using backside exposure of SU-8 , 2004 .

[7]  K. E. Jones,et al.  A glass/silicon composite intracortical electrode array , 2006, Annals of Biomedical Engineering.

[8]  Thomas Stieglitz,et al.  Flexible Multikanal-Mikroelektroden mit integrierten Zuleitungen zum Einsatz in der Neuroprothetik , 1997 .

[9]  J. Rubinstein,et al.  In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes , 1991, IEEE Transactions on Biomedical Engineering.

[10]  D. Beebe,et al.  Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer , 2000, Journal of Microelectromechanical Systems.

[11]  B. Schmidt,et al.  Whole cell recordings of lumbar motoneurons during locomotor-like activity in the in vitro neonatal rat spinal cord. , 1998, Journal of neurophysiology.

[12]  George M. Whitesides,et al.  Electroluminescent Materials with Feature Sizes as Small as 5 μm Using Elastomeric Membranes as Masks for Dry Lift‐Off , 1999 .

[13]  B. Wheeler,et al.  A flexible perforated microelectrode array for extended neural recordings , 1992, IEEE Transactions on Biomedical Engineering.

[14]  Carlos González,et al.  A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues , 1997, Journal of Neuroscience Methods.

[15]  S. Kelly,et al.  Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays. , 2003, Investigative ophthalmology & visual science.

[16]  James D. Weiland,et al.  The Dependence of Spectral Impedance on Disc Microelectrode Radius , 2008, IEEE Transactions on Biomedical Engineering.

[17]  Andreas Hierlemann,et al.  Impedance characterization and modeling of electrodes for biomedical applications , 2005, IEEE Transactions on Biomedical Engineering.

[18]  D. Polla,et al.  Stretchable micro-electrode array [for retinal prosthesis] , 2002, 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578).

[19]  David A. Borkholder,et al.  Cell based biosensors using microelectrodes , 1998 .

[20]  H. Oka,et al.  A new planar multielectrode array for extracellular recording: application to hippocampal acute slice , 1999, Journal of Neuroscience Methods.

[21]  O. Kiehn,et al.  Spatiotemporal characteristics of 5-HT and dopamine-induced rhythmic hindlimb activity in the in vitro neonatal rat. , 1996, Journal of neurophysiology.

[22]  D. Bertrand,et al.  A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices , 2002, Journal of Neuroscience Methods.

[23]  Steve M. Potter,et al.  Effective parameters for stimulation of dissociated cultures using multi-electrode arrays , 2004, Journal of Neuroscience Methods.

[24]  S. Kelly,et al.  Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials. , 2003, Investigative ophthalmology & visual science.

[25]  Kensall D. Wise,et al.  A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology , 1975, IEEE Transactions on Biomedical Engineering.

[26]  K. Cheung Implantable microscale neural interfaces , 2007, Biomedical microdevices.

[27]  John A. Rogers,et al.  Low-cost, low-loss microlens arrays fabricated by soft-lithography replication process , 2003 .

[28]  Hyun Soo Kim,et al.  Micropatterning of poly(dimethylsiloxane) using a photoresist lift-off technique for selective electrical insulation of microelectrode arrays , 2009, Journal of micromechanics and microengineering : structures, devices, and systems.

[29]  T Stieglitz,et al.  [Flexible multichannel microelectrodes with integrated leads for use in neuroprosthetics]. , 1997, Biomedizinische Technik. Biomedical engineering.

[30]  E. Garcia-Rill,et al.  Spinal cord stimulation-induced locomotion in the adult cat , 1992, Brain Research Bulletin.

[31]  Christopher S. Chen,et al.  High‐Conductivity Elastomeric Electronics , 2004 .

[32]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[33]  Isao Shimoyama,et al.  A radio-telemetry system with a shape memory alloy microelectrode for neural recording of freely moving insects , 2004, IEEE Transactions on Biomedical Engineering.

[34]  J. Newman Current Distribution on a Rotating Disk below the Limiting Current , 1966 .

[35]  Jay T. Rubinstein,et al.  Current Density Profiles of Surface Mounted and Recessed Electrodes for Neural Prostheses , 1987, IEEE Transactions on Biomedical Engineering.

[36]  Stephen P. DeWeerth,et al.  PDMS-based conformable microelectrode arrays with selectable novel 3-D microelectrode geometries for surface stimulation and recording , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[37]  K. Horch,et al.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[38]  V. Edgerton,et al.  Hindlimb stepping movements in complete spinal rats induced by epidural spinal cord stimulation , 2005, Neuroscience Letters.

[39]  D F Stegeman,et al.  A thin, flexible multielectrode grid for high-density surface EMG. , 2004, Journal of applied physiology.

[40]  Liang Guo,et al.  A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord , 2008, Biomedical microdevices.

[41]  Spun-cast micromolding for etchless micropatterning of electrically functional PDMS structures , 2009 .

[42]  M. Dimitrijevic,et al.  Evidence for a Spinal Central Pattern Generator in Humans a , 1998, Annals of the New York Academy of Sciences.

[43]  Barbara L. Shay,et al.  Serotonin 5-HT2 receptors induce a long-lasting facilitation of spinal reflexes independent of ionotropic receptor activity. , 2005, Journal of neurophysiology.

[44]  K. Wise,et al.  An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.

[45]  S. Rossignol,et al.  Nonlocomotor and locomotor hindlimb responses evoked by electrical microstimulation of the lumbar cord in spinalized cats. , 2006, Journal of neurophysiology.

[46]  S.F. Cogan,et al.  Electrodeposited iridium oxide for neural stimulation and recording electrodes , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[47]  Formation of locomotor patterns in decerebrate cats in conditions of epidural stimulation of the spinal cord , 2005, Neuroscience and Behavioral Physiology.

[48]  G. Gross Simultaneous Single Unit Recording in vitro with a Photoetched Laser Deinsulated Gold Multimicroelectrode Surface , 1979, IEEE Transactions on Biomedical Engineering.

[49]  Zhe Yu,et al.  Stretchable micro-electrode arrays for dynamic neuronal recording of in vitro mechanically injured brain , 2005, IEEE Sensors, 2005..

[50]  Christopher R. Stambaugh,et al.  Simultaneous encoding of tactile information by three primate cortical areas , 1998, Nature Neuroscience.

[51]  Qing Bai,et al.  Single-unit neural recording with active microelectrode arrays , 2001, IEEE Transactions on Biomedical Engineering.

[52]  Locomotor rhythm evoked by ventrolateral funiculus stimulation in the neonatal rat spinal cord in vitro. , 1997, Journal of neurophysiology.

[53]  David C. Martin,et al.  Fuzzy gold electrodes for lowering impedance and improving adhesion with electrodeposited conducting polymer films , 2003 .