Islanding detection method with negative-sequence current injection under unbalanced grid voltage

This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with a three-phase inverter which is connected to the unbalanced AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase-Locked Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides secure and rapid detection under the sag and swell of AC grid voltage. The feasibility of the proposed method was verified by computer simulations with PSCAD/EMTDC and experiments with a 5kW hardware set-up, considering the test circuit of islanding detection suggested by IEEE 1547 and UL1741.

[1]  K. Takigawa,et al.  A development of compact and reliable protective control unit for grid connected small residential PV systems , 1994, Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC).

[2]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[3]  Russell H. Bonn,et al.  Development and Testing of an Approach to Anti-Islanding in Utility-Interconnected Photovoltaic Systems , 2000 .

[4]  Seung-Ki Sul,et al.  Anti-islanding detection method using Negative Sequence Voltage , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[5]  Kwang-Ho Kim,et al.  Development of a logical rule-based islanding detection method for distributed resources , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[6]  Chern-Lin Chen,et al.  Automatic phase-shift method for islanding detection of grid-connected photovoltaic inverters , 2002 .

[7]  L.A.C. Lopes,et al.  Performance assessment of active frequency drifting islanding detection methods , 2006, IEEE Transactions on Energy Conversion.

[8]  Ajeet Rohatgi,et al.  Analysis and performance assessment of the active frequency drift method of islanding prevention , 1999 .

[9]  Thierry Van Craenenbroeck Copper Development Association Voltage Disturbances Introduction to Unbalance , 2002 .

[10]  T. R. Sims,et al.  Investigation of potential islanding problems of a line-commutated static power converter in photovoltaic systems , 1990 .

[11]  Goro Fujita,et al.  Negative-sequence Current Injection of Dispersed Generation for Islanding Detection and Unbalanced Fault Ride-through , 2012 .

[12]  R. Iravani,et al.  Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit , 2008, IEEE Transactions on Power Electronics.

[13]  Xuan Liu,et al.  Active islanding detection method based on grid-connected photovoltaic inverter and negative sequence current injection , 2014, 2014 International Conference on Power System Technology.