Construction and Evaluation of Quantitative Small-Animal PET Probabilistic Atlases for [18F]FDG and [18F]FECT Functional Mapping of the Mouse Brain

Automated voxel-based or pre-defined volume-of-interest (VOI) analysis of small-animal PET data in mice is necessary for optimal information usage as the number of available resolution elements is limited. We have mapped metabolic ([18F]FDG) and dopamine transporter ([18F]FECT) small-animal PET data onto a 3D Magnetic Resonance Microscopy (MRM) mouse brain template and aligned them in space to the Paxinos co-ordinate system. In this way, ligand-specific templates for sensitive analysis and accurate anatomical localization were created. Next, using a pre-defined VOI approach, test-retest and intersubject variability of various quantification methods were evaluated. Also, the feasibility of mouse brain statistical parametric mapping (SPM) was explored for [18F]FDG and [18F]FECT imaging of 6-hydroxydopamine-lesioned (6-OHDA) mice. Methods Twenty-three adult C57BL6 mice were scanned with [18F]FDG and [18F]FECT. Registrations and affine spatial normalizations were performed using SPM8. [18F]FDG data were quantified using (1) an image-derived-input function obtained from the liver (cMRglc), using (2) standardized uptake values (SUVglc) corrected for blood glucose levels and by (3) normalizing counts to the whole-brain uptake. Parametric [18F]FECT binding images were constructed by reference to the cerebellum. Registration accuracy was determined using random simulated misalignments and vectorial mismatch determination. Results Registration accuracy was between 0.21–1.11 mm. Regional intersubject variabilities of cMRglc ranged from 15.4% to 19.2%, while test-retest values were between 5.0% and 13.0%. For [18F]FECT uptake in the caudate-putamen, these values were 13.0% and 10.3%, respectively. Regional values of cMRglc positively correlated to SUVglc measured within the 45–60 min time frame (spearman r = 0.71). Next, SPM analysis of 6-OHDA-lesioned mice showed hypometabolism in the bilateral caudate-putamen and cerebellum, and an unilateral striatal decrease in DAT availability. Conclusion MRM-based small-animal PET templates facilitate accurate assessment and spatial localization of mouse brain function using VOI or voxel-based analysis. Regional intersubject- and test-retest variations indicate that for these targets accuracy comparable to humans can be achieved.

[1]  Michael E. Phelps,et al.  Quantification of Cerebral Glucose Metabolic Rate in Mice Using 18F-FDG and Small-Animal PET , 2009, Journal of Nuclear Medicine.

[2]  J. J. Sychra,et al.  Erratum: ‘‘The accuracy of SPECT brain activation images: Propagation of registration errors’’ [Med. Phys. 21, 1585–1590 (1994)] , 1994 .

[3]  Sung-Cheng Huang,et al.  Effects of Administration Route, Dietary Condition, and Blood Glucose Level on Kinetics and Uptake of 18F-FDG in Mice , 2011, The Journal of Nuclear Medicine.

[4]  D G Pavel,et al.  The accuracy of SPECT brain activation images: propagation of registration errors. , 1994, Medical physics.

[5]  S. Siegel,et al.  Performance evaluation of the microPET focus: a third-generation microPET scanner dedicated to animal imaging. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Jeih-San Liow,et al.  Evaluation of anesthesia effects on [18F]FDG uptake in mouse brain and heart using small animal PET. , 2004, Nuclear medicine and biology.

[7]  Simon R Cherry,et al.  Small-animal preclinical nuclear medicine instrumentation and methodology. , 2008, Seminars in nuclear medicine.

[8]  Scott Hamilton,et al.  In Vivo 3D Digital Atlas Database of the Adult C57BL/6J Mouse Brain by Magnetic Resonance Microscopy , 2008, Frontiers in neuroanatomy.

[9]  Simon R Cherry,et al.  Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays , 2009, Physics in medicine and biology.

[10]  R. Leahy,et al.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data , 2007, Physics in medicine and biology.

[11]  R J Zatorre,et al.  Stability of regional cerebral glucose metabolism in the normal brain measured by positron emission tomography. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  L. Swanson The Rat Brain in Stereotaxic Coordinates, George Paxinos, Charles Watson (Eds.). Academic Press, San Diego, CA (1982), vii + 153, $35.00, ISBN: 0 125 47620 5 , 1984 .

[13]  W. Oyen,et al.  FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0 , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[14]  Jogeshwar Mukherjee,et al.  Performance evaluation of an Inveon PET preclinical scanner , 2008, Physics in medicine and biology.

[15]  M. Dhenain,et al.  Increased regional cerebral glucose uptake in an APP/PS1 model of Alzheimer's disease , 2012, Neurobiology of Aging.

[16]  L. Hedlund,et al.  Morphologic phenotyping with MR microscopy: the visible mouse. , 2002, Radiology.

[17]  J. Haller,et al.  Current animal models of anxiety, anxiety disorders, and anxiolytic drugs , 2012, Current opinion in psychiatry.

[18]  G. Bormans,et al.  Improved synthesis and metabolic stability analysis of the dopamine transporter ligand [(18)F]FECT. , 2008, Nuclear medicine and biology.

[19]  M. Raichle,et al.  A Stereotactic Method of Anatomical Localization for Positron Emission Tomography , 1985, Journal of computer assisted tomography.

[20]  Ingeborg Goethals,et al.  Analysis of clinical brain SPECT data based on anatomic standardization and reference to normal data: an ROC-based comparison of visual, semiquantitative, and voxel-based methods. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  R. Boellaard,et al.  Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  Alan C. Evans,et al.  A three-dimensional MRI atlas of the mouse brain with estimates of the average and variability. , 2005, Cerebral cortex.

[23]  John R. Votaw,et al.  Isoflurane Alters the Amount of Dopamine Transporter Expressed on the Plasma Membrane in Humans , 2004, Anesthesiology.

[24]  Sung-Cheng Huang,et al.  Anatomy of SUV , 2000 .

[25]  Masanori Ichise,et al.  Reproducibility of dopamine transporter density measured with123I-FPCIT SPECT in normal control and Parkinson’s disease patients , 2004, Annals of nuclear medicine.

[26]  Alain Pitiot,et al.  A multimodal, multidimensional atlas of the C57BL/6J mouse brain , 2004, Journal of anatomy.

[27]  J. Chou,et al.  Brain Contains a Functional Glucose-6-Phosphatase Complex Capable of Endogenous Glucose Production* , 2005, Journal of Biological Chemistry.

[28]  Simon R. Cherry,et al.  Development and evaluation of an automated atlas-based image analysis method for microPET studies of the rat brain , 2003, NeuroImage.

[29]  Jesper L. R. Andersson,et al.  A template for spatial normalisation of MR images of the rat brain , 2003, Journal of Neuroscience Methods.

[30]  I. Kanno,et al.  Automated interstudy image registration technique for SPECT and PET. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[31]  Martine M. Mirrione,et al.  Optimizing experimental protocols for quantitative behavioral imaging with 18F-FDG in rodents. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[32]  Sung-Cheng Huang,et al.  In Vivo Quantitation of Glucose Metabolism in Mice Using Small-Animal PET and a Microfluidic Device , 2007, Journal of Nuclear Medicine.

[33]  J. Keyes SUV: standard uptake or silly useless value? , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[34]  J Nucl Med , 2010 .

[35]  S C Huang,et al.  Anatomy of SUV. Standardized uptake value. , 2000, Nuclear medicine and biology.

[36]  Habib Zaidi,et al.  Automated analysis of small animal PET studies through deformable registration to an atlas , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[37]  Johan Nuyts,et al.  Construction and evaluation of multitracer small-animal PET probabilistic atlases for voxel-based functional mapping of the rat brain. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[38]  David S. Park,et al.  Animal Models of Parkinson's Disease , 2011, Parkinson's disease.

[39]  Bernd J. Pichler,et al.  In vivo quantification of dopamine transporters in mice with unilateral 6-OHDA lesions using [11C]methylphenidate and PET , 2012, NeuroImage.

[40]  Anders M. Dale,et al.  Three-Dimensional Atlas System for Mouse and Rat Brain Imaging Data , 2007, Frontiers Neuroinformatics.

[41]  Jeih-San Liow,et al.  Linearized Reference Tissue Parametric Imaging Methods: Application to [11C]DASB Positron Emission Tomography Studies of the Serotonin Transporter in Human Brain , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.