Adaptive optics for fluorescence correlation spectroscopy.

Fluorescence Correlation Spectroscopy (FCS) yields measurement parameters (number of molecules, diffusion time) that characterize the concentration and kinetics of fluorescent molecules within a supposedly known observation volume. Absolute derivation of concentrations and diffusion constants therefore requires preliminary calibrations of the confocal Point Spread Function with phantom solutions under perfectly controlled environmental conditions. In this paper, we quantify the influence of optical aberrations on single photon FCS and demonstrate a simple Adaptive Optics system for aberration correction. Optical aberrations are gradually introduced by focussing the excitation laser beam at increasing depths in fluorescent solutions with various refractive indices, which leads to drastic depth-dependent bias in the estimated FCS parameters. Aberration correction with a Deformable Mirror stabilizes these parameters within a range of several tens of μm into the solution. We also demonstrate, both theoretically and experimentally, that the molecular brightness scales as the Strehl ratio squared.

[1]  Elliot L Elson,et al.  Quick tour of fluorescence correlation spectroscopy from its inception. , 2004, Journal of biomedical optics.

[2]  H. Rigneault,et al.  A versatile dual spot laser scanning confocal microscopy system for advanced fluorescence correlation spectroscopy analysis in living cell. , 2009, The Review of scientific instruments.

[3]  Enrico Gratton,et al.  Lessons in fluctuation correlation spectroscopy. , 2011, Annual review of physical chemistry.

[4]  J. Enderlein,et al.  Dual-focus fluorescence correlation spectroscopy: a robust tool for studying molecular crowding , 2009 .

[5]  Bo Huang,et al.  Photon counting histogram: one-photon excitation. , 2004, Chemphyschem : a European journal of chemical physics and physical chemistry.

[6]  Joachim D. Müller,et al.  Cumulant analysis in fluorescence fluctuation spectroscopy. , 2004, Biophysical journal.

[7]  R. Rigler,et al.  Fluorescence correlation spectroscopy of triplet states in solution: a theoretical and experimental study , 1995 .

[8]  Xiaodong Tao,et al.  Adaptive optics microscopy with direct wavefront sensing using fluorescent protein guide stars. , 2011, Optics letters.

[9]  J. Enderlein,et al.  The optics and performance of dual-focus fluorescence correlation spectroscopy. , 2008, Optics express.

[10]  T Wilson,et al.  Closed-loop aberration correction by use of a modal Zernike wave-front sensor. , 2000, Optics letters.

[11]  Tony Wilson,et al.  New modal wave-front sensor: application to adaptive confocal fluorescence microscopy and two-photon excitation fluorescence microscopy. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Bo Huang,et al.  Photon counting histogram for one-photon excitation. , 2003, Chemphyschem : a European journal of chemical physics and physical chemistry.

[13]  J. Langowski,et al.  Mapping eGFP Oligomer Mobility in Living Cell Nuclei , 2009, PloS one.

[14]  R Macdonald,et al.  Comparison and accuracy of methods to determine the confocal volume for quantitative fluorescence correlation spectroscopy , 2008, Journal of microscopy.

[15]  D. Gavel,et al.  Adaptive optics wide-field microscopy using direct wavefront sensing. , 2011, Optics letters.

[16]  Daren Dillon,et al.  Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference beacons , 2010, Optics express.

[17]  T. Wilson,et al.  Characterizing specimen induced aberrations for high NA adaptive optical microscopy. , 2004, Optics express.

[18]  P. Schwille,et al.  Fluorescence correlation spectroscopy: novel variations of an established technique. , 2007, Annual review of biophysics and biomolecular structure.

[19]  Xiaodong Tao,et al.  Adaptive optics confocal microscopy using direct wavefront sensing. , 2011, Optics letters.

[20]  T. Wilson,et al.  Aberration correction for confocal imaging in refractive‐index‐mismatched media , 1998 .

[21]  W. Webb,et al.  Focal volume optics and experimental artifacts in confocal fluorescence correlation spectroscopy. , 2002, Biophysical journal.

[22]  J. Mertz,et al.  Molecular photodynamics involved in multi-photon excitation fluorescence microscopy , 1998 .

[23]  A. Jesacher,et al.  Adaptive Optics for Biomedical Microscopy , 2012 .