Consistent multi-time-point brain atrophy estimation from the boundary shift integral

Brain atrophy measurement is increasingly important in studies of neurodegenerative diseases such as Alzheimer's disease (AD), with particular relevance to trials of potential disease-modifying drugs. Automated registration-based methods such as the boundary shift integral (BSI) have been developed to provide more precise measures of change from a pair of serial MR scans. However, when a method treats one image of the pair (typically the baseline) as the reference to which the other is compared, this systematic asymmetry risks introducing bias into the measurement. Recent concern about potential biases in longitudinal studies has led to several suggestions to use symmetric image registration, though some of these methods are limited to two time-points per subject. Therapeutic trials and natural history studies increasingly involve several serial scans, it would therefore be useful to have a method that can consistently estimate brain atrophy over multiple time-points. Here, we use the log-Euclidean concept of a within-subject average to develop affine registration and differential bias correction methods suitable for any number of time-points, yielding a longitudinally consistent multi-time-point BSI technique. Baseline, 12-month and 24-month MR scans of healthy controls, subjects with mild cognitive impairment and AD patients from the Alzheimer's Disease Neuroimaging Initiative are used for testing the bias in processing scans with different amounts of atrophy. Four tests are used to assess bias in brain volume loss from BSI: (a) inverse consistency with respect to ordering of pairs of scans 12 months apart; (b) transitivity consistency over three time-points; (c) randomly ordered back-to-back scans, expected to show no consistent change over subjects; and (d) linear regression of the atrophy rates calculated from the baseline and 12-month scans and the baseline and 24-month scans, where any additive bias should be indicated by a non-zero intercept. Results indicate that the traditional BSI processing pipeline does not exhibit significant bias due to its use of windowed sinc interpolation, but with linear interpolation and asymmetric registration, bias can be pronounced. Either improved interpolation or symmetric registration alone can greatly reduce this bias, and our proposed method combining both aspects shows no significant bias in any of the four experiments.

[1]  Alan C. Evans,et al.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data , 1998, IEEE Transactions on Medical Imaging.

[2]  Stanislav Kovacic,et al.  Symmetric image registration , 2003, SPIE Medical Imaging.

[3]  Emma B. Lewis,et al.  Correction of differential intensity inhomogeneity in longitudinal MR images , 2004, NeuroImage.

[4]  Daniel Rueckert,et al.  Cerebral atrophy measurements using Jacobian integration: Comparison with the boundary shift integral , 2006, NeuroImage.

[5]  Gary E. Christensen,et al.  Transitive Inverse-Consistent Manifold Registration , 2005, IPMI.

[6]  Dinggang Shen,et al.  HAMMER: hierarchical attribute matching mechanism for elastic registration , 2002, IEEE Transactions on Medical Imaging.

[7]  Deshan Yang,et al.  A fast inverse consistent deformable image registration method based on symmetric optical flow computation , 2008, 2008 42nd Asilomar Conference on Signals, Systems and Computers.

[8]  Sébastien Ourselin,et al.  Brain MAPS: An automated, accurate and robust brain extraction technique using a template library , 2011, NeuroImage.

[9]  Object-Oriented Real-Time Third IEEE International Symposium on , 2000 .

[10]  Gary E. Christensen,et al.  Consistent image registration , 2001, IEEE Transactions on Medical Imaging.

[11]  Nick C Fox,et al.  The Alzheimer's disease neuroimaging initiative (ADNI): MRI methods , 2008, Journal of magnetic resonance imaging : JMRI.

[12]  Hemant D. Tagare,et al.  Symmetric and Transitive Registration of Image Sequences , 2008, Int. J. Biomed. Imaging.

[13]  Brian B. Avants,et al.  Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain , 2008, Medical Image Anal..

[14]  Bruce Fischl,et al.  Highly accurate inverse consistent registration: A robust approach , 2010, NeuroImage.

[15]  Nick C Fox,et al.  Imaging cerebral atrophy: normal ageing to Alzheimer's disease , 2004, The Lancet.

[16]  C. Jack,et al.  Comparison of different MRI brain atrophy rate measures with clinical disease progression in AD , 2004, Neurology.

[17]  P. Narayana,et al.  Compensation for surface coil sensitivity variation in magnetic resonance imaging. , 1988, Magnetic resonance imaging.

[18]  Wendy R. Sanhai,et al.  Biomarkers for Alzheimer's disease: academic, industry and regulatory perspectives , 2010, Nature Reviews Drug Discovery.

[19]  Brian B. Avants,et al.  Bias in estimation of hippocampal atrophy using deformation-based morphometry arises from asymmetric global normalization: An illustration in ADNI 3 T MRI data , 2010, NeuroImage.

[20]  Yunmei Chen,et al.  A New Algorithm for Inverse Consistent Image Registration , 2009, ISVC.

[21]  Norbert Schuff,et al.  Validation Testing of the MRI Calibration Phantom for the Alzheimer's Disease Neuroimaging Initiative Study , 2006 .

[22]  D. Selkoe Alzheimer's disease. , 2011, Cold Spring Harbor perspectives in biology.

[23]  Torsten Rohlfing,et al.  Shape-Based Averaging , 2007, IEEE Transactions on Image Processing.

[24]  Nick C. Fox,et al.  Algorithms, atrophy and Alzheimer's disease: Cautionary tales for clinical trials , 2011, NeuroImage.

[25]  Ali R. Khan,et al.  Symmetric Data Attachment Terms for Large Deformation Image Registration , 2007, IEEE Transactions on Medical Imaging.

[26]  Wesley K. Thompson,et al.  Bias in tensor based morphometry Stat-ROI measures may result in unrealistic power estimates , 2011, NeuroImage.

[27]  Norbert Schuff,et al.  Optimizing power to track brain degeneration in Alzheimer's disease and mild cognitive impairment with tensor-based morphometry: An ADNI study of 515 subjects , 2009, NeuroImage.

[28]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[29]  Nicholas Ayache,et al.  A Log-Euclidean Polyaffine Framework for Locally Rigid or Affine Registration , 2006, WBIR.

[30]  A. Brun,et al.  Regional pattern of degeneration in Alzheimer's disease: neuronal loss and histopathological grading , 1981, Histopathology.

[31]  Michael Weiner,et al.  Comparison of phantom and registration scaling corrections using the ADNI cohort , 2009, NeuroImage.

[32]  Adam G. Thomas,et al.  Functional but not structural changes associated with learning: An exploration of longitudinal Voxel-Based Morphometry (VBM) , 2009, NeuroImage.

[33]  Marc Alexa,et al.  Linear combination of transformations , 2002, ACM Trans. Graph..

[34]  Nick C Fox,et al.  Interactive algorithms for the segmentation and quantitation of 3-D MRI brain scans. , 1997, Computer methods and programs in biomedicine.

[35]  M. Albert,et al.  MRI measures of temporoparietal regions show differential rates of atrophy during prodromal AD , 2008, Neurology.

[36]  Paul M. Thompson,et al.  Inverse Consistent Mapping in 3D Deformable Image Registration: Its Construction and Statistical Properties , 2005, IPMI.

[37]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[38]  Daniel Rueckert,et al.  Analysis of growth in the developing brain using non-rigid registration , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[39]  Norbert Schuff,et al.  Accurate measurement of brain changes in longitudinal MRI scans using tensor-based morphometry , 2011, NeuroImage.

[40]  C. Jack,et al.  Atrophy rates accelerate in amnestic mild cognitive impairment , 2008, Neurology.

[41]  M N Rossor,et al.  Correlation between rates of brain atrophy and cognitive decline in AD , 1999, Neurology.

[42]  Michael Weiner,et al.  Robust atrophy rate measurement in Alzheimer's disease using multi-site serial MRI: Tissue-specific intensity normalization and parameter selection , 2010, NeuroImage.

[43]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[44]  Nick C Fox,et al.  Reduced sample sizes for atrophy outcomes in Alzheimer's disease trials: baseline adjustment , 2010, Neurobiology of Aging.

[45]  Nicholas Ayache,et al.  A Fast and Log-Euclidean Polyaffine Framework for Locally Linear Registration , 2009, Journal of Mathematical Imaging and Vision.

[46]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[47]  C. Jack,et al.  Longitudinal MRI findings from the vitamin E and donepezil treatment study for MCI , 2008, Neurobiology of Aging.

[48]  P. Matthews,et al.  Normalized Accurate Measurement of Longitudinal Brain Change , 2001, Journal of computer assisted tomography.

[49]  J C Mazziotta,et al.  Automated image registration: II. Intersubject validation of linear and nonlinear models. , 1998, Journal of computer assisted tomography.

[50]  Brian B. Avants,et al.  Sparse Unbiased Analysis of Anatomical Variance in Longitudinal Imaging , 2010, MICCAI.

[51]  Max A. Viergever,et al.  Quantitative Comparison of Sinc-Approximating Kernels for Medical Image Interpolation , 1999, MICCAI.

[52]  T. Iwatsubo [Alzheimer's disease Neuroimaging Initiative (ADNI)]. , 2011, Nihon rinsho. Japanese journal of clinical medicine.

[53]  A. Dale,et al.  Unbiased comparison of sample size estimates from longitudinal structural measures in ADNI , 2012, Human brain mapping.

[54]  Nick C Fox,et al.  Change in rates of cerebral atrophy over time in early-onset Alzheimer's disease: longitudinal MRI study , 2003, The Lancet.

[55]  Nick C Fox,et al.  A longitudinal study of brain volume changes in normal aging using serial registered magnetic resonance imaging. , 2003, Archives of neurology.

[56]  Bruce Fischl,et al.  Avoiding asymmetry-induced bias in longitudinal image processing , 2011, NeuroImage.

[57]  Paul M. Thompson,et al.  Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coils , 2008, NeuroImage.

[58]  Roger P. Woods,et al.  Characterizing volume and surface deformations in an atlas framework: theory, applications, and implementation , 2003, NeuroImage.

[59]  Anders M. Dale,et al.  Reliability in multi-site structural MRI studies: Effects of gradient non-linearity correction on phantom and human data , 2006, NeuroImage.